H8/3257 Series, H8/325 Series FP-64A User System Interface Cable (HS3257ECH61H) for E6000 Emulator User’s Manual ADE-xxx-xxx Rev. 3.0 4/1/03 Renesas Technology Corp.
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing the E6000 em ulator for the Renesas’s original m icroprocessor H8/300 series. The HS3257ECH61H is a user system interface cable that connects an H8/300 series E600.
ii Contents Section 1 Configuration ..................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
Section 1 Configuration CAUTION Use an IC149-064-008-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64A package IC socket on the user system. Figure 1 shows the configuration of the HS3257E CH61H user system interface cable for the FP-64A package IC socket Cable head User system Socket cover Screws (M2.
2 Table 1 lists the HS3257ECH61H com ponents. Please m ake sure you have all of these components when unpacking. Table 1 HS3257ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes cables 2 Cable head 1 3 IC socket 1 For the FP-64A package 4 Socket cover 1 For installing an FP-64A-packaged MCU 5 Screws (M2.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY.
Figure 2 Connecting User System Int erface Cable to Emulator Station 2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part.
5 2.2.2 Soldering IC Socket After fastening, solder the IC socket for an FP-64A package to the user system. Be sure to completely solder the leads so that the solder slo p s gently over the leads and fo rms solder fillets. (Use slightly more solder than the MCU.
Screws (M2.0 x 12 mm) and flat washers Cable head Pin 1 IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 3 Connecting User System Interface Cable to User .
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Cable head Unfastening jig Push the unfastening jig Removing User system Figure 4 Fastening Cable Body 7.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recomm ended dime nsions for the mount pad (foot print) for the user system with an IC socket for an FP-64A package (IC149-064-008-B5: manufactured by YAM AICHI ELECTRONICS Co., Ltd.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 9.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7. 9.4 Unit: mm Tolerance: ± 0.5 mm User system IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co.
11 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head.
MCU Pin 1 mark User system Socket cover IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) Figure 8 Installing MCU to User System 12.
Section 4 Verifying Operation 1. When using the H8/300 series E6000 emulat or (HS3008EPI60H), turn on the emulat or according to the procedures described in th e H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE).
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MC U.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Renesas H8/325 Series c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Renesas H8/325 Series - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Renesas H8/325 Series, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Renesas H8/325 Series va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Renesas H8/325 Series, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Renesas H8/325 Series.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Renesas H8/325 Series. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Renesas H8/325 Series ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.