2004.1.29 SH7046 Group FP-80Q User System Interfa ce Board HS7046ECH61H User’s Manual Renesas M icrocomput er Developm ent Enviro nment System SuperH TM Family /SH7046 S eries Rev.
Cautions Keep safety first in your circ uit designs! 1. Renesas Technology Corp. put s the maximum e ffort int o making semi conductor pr oducts better and more reliable, but the re is always the possibility that trouble may occur with them. Trouble with semi conductors may l ead to personal i njury, fire or property dama ge.
I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this u ser system interface board. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user system interface bo ard until you fully under stand its mec ha ni s m.
II LIMITED WARRANTY Renesas warrants its user system interface boards to be manufa ctured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will re pair or replace any user system interfac e boards determined to be defe ctive in material and/or workmanship.
III State Law: Some states do not allo w the exclusion or limitatio n of implied warranties or liabilit y for incidental o r consequential d amages, so t he ab o ve limitation or excl usion ma y not appl y to you. This warr ant y give s yo u spec if ic lega l rig hts, and you ma y have ot her rig hts wh ic h may va ry fro m state to state.
IV SAFETY PAGE READ FIRST • READ this user's manual before using this u ser system interface board. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user system interface bo ard until you fully under stand its mec ha ni s m.
V W ARNING Observe the pr ecautions listed below. Failure to do so will result in a FIRE HA ZARD and will damag e the user system and the emula tor product or will result in PERSONAL INJURY. Th e USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product b y yourself for e lectric shock pr evention and qualit y assurance.
i Preface The HS7046ECH61H is a u ser sys tem in terface board that conn ects a user sy stem for the S H7046 FP-80Q packag e to the SH7046 E6000H em ul ator (HS7046EPH60H).
ii Contents Section 1 Configuration ..................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connectin g User System Interf ace Board to User System .
1 Section 1 Configuration Figure 1 and table 1 sh ow th e configu ration and compon ents of the u ser system interface board f or the FP-80Q packag e. Please make sure y ou hav e all of these com ponents w hen un packing. Socket cover Screws (M2.0 x 8 mm) with flat washers EV-chip board Board User system Spacer IC socket Screws (M2.
2 CAUTION Use an IC149-080- 017-B5 socket (manuf actured by YAMAICH I ELECTRONICS Co., Ltd.) for the FP-80Q package IC socket on the user syst em. Table 1 HS7046ECH61H Compon ents No.
3 Section 2 Connection Procedures 2.1 Connectin g User System Interface Board to User S ystem W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned.
4 2.1.2 Installing Cable Hea d CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC sock et for an FP-80Q packag e on the user sy stem with pin 1 on the us er system interface board, an d insert the user sy stem interface board into th e IC socket on the u ser system , as shown in figure 2.
5 Screws (M2.0 x 12 mm) with flat washers Pin 1 Board IC socket (IC 149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 2 Connecting User System Interface Board to User S.
6 2.2 Connecting User System Interface Board to EV-Chip Board W ARNING Observe the precautions listed below. Failure t o do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
7 Connector No. UCN1 UCN1 UCN2 UCN2 Board EV-Chip Board Connector No. Board Connector No. EV-chip board Spacer User system Figure 3 Connecting User System Interface Board to EV-Chip Board.
8 2.3 Recom me nded Dim ensions for User System M ount Pad ( Footprint) Figure 4 show s the recom m ended dimens ions for the m ount pad (f ootprint) for the us er system w ith an IC socket f or an FP-80Q packag e (IC149-080- 017-B5: m anuf actured by YAMAIC HI ELECTRONICS C o.
9 2.4 Dim ensions for EV-Chip Boar d and User Syste m Inter face Board The dimens ions for the EV- chip board and the u ser system interface board are show n in figure 5. 140.0 19.5 31.0 33.5 16.0 100.0 116.0 92.0 69.0 29.5 5.0 34.5 Unit: mm Tolerance: ±0.
10 2.5 Resultin g Dimensions after Con necting User System Interf ace Board The resulting dim ensions, af ter connecting th e user system interface board to th e user system , are shown in figure 6. Unit: mm Tolerance: ±1.0 mm User system EV-chip board IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co.
11 Section 3 Installing the MCU to the User System CAUTION 1. Check the locat ion of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head.
12 MCU (SH7046) Screws (M2.0 x 8 mm) with flat washers Socket cover Pin 1 User system IC socket (IC 149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co.
13 Section 4 Verifying Operation 1. Turn on the em ulator accordin g to the procedures described in the SH7046 E6000H Em ulator User's Manual (HS 7046EPH60HE).
14 To use the crystal oscillator mounted on the EV-chip board Install a crystal oscillator into the crys tal oscillator terminals on the EV-chip board.
15 Section 5 Notice 1. Before connectin g any parts or cables, make su re that pin 1 on the both sides are correctly aligned. 2. Do not apply excessive force to the u ser system interface board w hile it is con nected to the user system .
SH7046 Group FP-80Q User System Interface Board HS7046ECH61H User's Manual Publication Date: Rev.4.00, January 29, 2004 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co.
SH7046 Group F P-80Q User Sy stem Inte rface B oard HS7046E C H61H U ser’ s Manual REJ10B0040-0400H.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Renesas FP-80Q c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Renesas FP-80Q - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Renesas FP-80Q, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Renesas FP-80Q va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Renesas FP-80Q, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Renesas FP-80Q.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Renesas FP-80Q. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Renesas FP-80Q ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.