Manuel d'utilisation / d'entretien du produit FP-144H du fabricant Renesas
Aller à la page of 19
H8S/2378 Series FP-144H User System Interface Cable (HS2378ECH61H) for E6000 Emulator User’s Manual ADE-xxx-xxx Rev. 2.0 4/1/03 Renesas Technology Corp.
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing this user system interface cable (HS2378ECH61H) for the Renesas’s original mi crocomputer H8S/2378 Series. The HS2378ECH61H is a user system interface cab le that .
ii Contents Section 1 Configuration ...................................................................................... 1 Section 2 Connection Procedures ....................................................................... 3 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
Section 1 Configuration CAUTION Use an IC149-144-045-B51 socket (manufactured by YAMAICHI ELECTRONICS CO., Ltd.) for the FP-144H package IC socket on the user system. Figure 1 shows the configuration of the HS2378E CH61H user system interface cable for the FP-144H package.
2 Table 1 lists t he HS2378ECH61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS2378ECH61H Components No. Component Quantity Remarks 1 Cable body 1 2 Cable .
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY.
Figure 2 Connecting User System Interf ace Cable to Emulator Station 4.
2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-144H system interface cable h ead into the IC socket on the user system, as shown i n figure 3. 2.2.4 Fastening Cable Head CAUTION 1.
Fasten the user system interface cable head to the IC socket fo r an FP-144H package on the user system with the four screws (M2 x 12 m m ; wit h four fl at washers) provided. Each screw shoul d be tightened a little at a time, alternating between scre ws on opposing corners.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. 8 Cable body Cable head User system unfastening jig Push the unfastening jigs. Removing Figure 4 Fastening Cable Body.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for an FP-144H package (IC149-144-045-B51: m anufactured by YAMAIC HI ELECTRONICS CO.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7.
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head.
Figure 8 Installing MCU to User System 13.
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2378 Series, turn on the emulator according to the procedures described in the E6000 Series Em ulator User's Ma nual (HS2000EPI61HE). 2. Verify the user system interface cable connec tions by accessing the exte rnal m emory and ports to check the bus states of the pins.
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Renesas FP-144H c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Renesas FP-144H - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Renesas FP-144H, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Renesas FP-144H va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Renesas FP-144H, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Renesas FP-144H.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Renesas FP-144H. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Renesas FP-144H ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.