SSP-100 Single Channel RS-232 PCMCIA Asynchronous Adapter for PCMCIA Card Standard compatible machines User's Manual QUATECH, INC. TEL: (330) 434-3154 662 Wolf Ledges Parkway FAX: (330) 434-1409 .
.
SSP-100 User's Manual i.
Warranty Information Quatech Inc. warrants the S SP-100 to be free of defects for five ( 5 ) year s from the date of purchase. Quatech Inc. will repair or replace any adapter that fails to perform under normal operating conditions and in accordance with the procedures outlined in this document during the warranty period.
Declaration of Conformity Manufacturer's Name: Quatech, Inc. M anufacturer's Address: 662 Wolf Ledges Parkway Akron, OH 44311 (USA) Application of Council Directive: 89/336/EEC Standards to .
Table of Contents 6-1 7 . Specifications ...................................................... 5-1 6 . External Connections ............................................. 4-8 5.2 Monitoring The Status Of PCMCIA Cards ............................... 4-7 5.
SSP-200/300 User's Manual 5.
1 . Introduction The SSP-100 is a single channel RS- 232 asynchronous serial adapter for systems equipped with PCMCIA Type II and/or Type III expansion sockets. The SSP-100 is a PCMCIA Type II (5 mm) card and is PCMCIA PC Card Standard Specification 2.
(This page intentionally left blank.) SSP-100 User's Manual 1-2.
2 . DOS / Windows 3.x Installation Two configuration software programs are provided with the SSP-100 : a Client Driver, and a card Enabler. Both of these programs are executed from DOS (before entering Windows) and allow operation of the SSP-100 in both the DOS and Windows 3.
2 . 1 SSP-100 Client Driver for DOS In order to use the SSP-100 Client Driver, the system must be configured with Card and Socket Services software. Card and Socket Services software is not provided with the SSP-100 but is available from Quatech .
version of Card and Socket Services must be installed on the system or the SSP-100 Enabler program must be used to configure the adapter. If the Client Driver reports the desired adapter configuration, the installation process is complete and the SSP-100 may be removed and/ or inserted from the system as desired.
option. If no number is specified, the SSP-100 will be configured as the next available COM Port using the standard base address and IRQ settings for that COM port.
DEVICE = C: SSP-100 SSP100CL.SYS (b300,i5) (i10) ( ) In example 5, three command line arguments are provided. The Client Driver will first attempt to configure a SSP-100 inserted into any socket with a base address of 300H and IRQ 5. The BIOS equipment list will not be updated.
2.1.2.7 Example 7 DEVICE = C: SSP-100 SSP100CL.SYS (s0,b300,i5) (s1,b340,i10) The type of configuration shown in example 7 may be desirable in systems where more than one SSP-100 is to be installed. In this example, the Client Driver will attempt to configure a SSP-100 inserted into socket 0 with a base address of 300H and IRQ 5.
2 . 1 . 3 Common Problems Generic Client Drivers: Many Card and Socket Services packages include a generic client driver (or SuperClient) which configures standard I/O devices. If one of these generic client drivers is installed, it may configure the SSP-100 causing the SSP-100 client driver to fail installation.
2 . 2 SSP-100 Enabler for DOS For systems that are not operating PCMCIA Card and Socket Services software, the SSP-100 DOS Enabler may be used to enable and configure the adapter.
2 . 2 . 1 Command Line Options To configure a SSP-100 in the system, the Enabler requires one command line argument from the user to determine the configuration of the card.
Before removing a SSP-100 from its PCMCIA socket, the Enabler should be executed to free the system resources allocated when the card was installed. For this operation the Enabler provides on additional command line option: R instructs the enabler to release the resources previously allocated to the SSP-100 .
2.2.1.4 Example 4 SSP100EN (s0,b300,i3,wd8) In example 4, the Enabler will configure the SSP-100 in socket 0 with a base address of 300H and IRQ 3 using a configuration memory window at segment D800.
SSP100EN (s0,a3) In Example 9, the Client Driver will attempt to configure an SSP-100 into socket 0 with the COM 3 standard address of 3E8H and IRQ 4. The COM 3 spot of the BIOS equipment list will be updated automatically.
2 . 2 . 2 Common Problems Memory Range Exclusion: The Enabler requires a region of high DOS memory when configuring a SSP-100 . This region is 1000H bytes (4KB) long and by default begins at address D0000H (the default address may be changed using the "W" option).
(This Page Left Intentionally Blank) SSP-100 User’s Manual 2-14.
3 . Windows 95 , 98, 2000, ME, NT Installation To allow easy configuration of the SSP-100 , a Windows "INF" configuration file has been written for the hardware. 3 . 1 Installing a SSP-100 Under Windows 95, 98, ME, 2000 . 1. Insert the SSP-100 into any available PC Card socket.
4. The New Hardware Found window provides several options to configure the SSP-100 card. Insert the CD with the Windows Configuration file, select “CD-ROM drive” and path, and click " Next ". Windows will browse the path for the necessary files.
Figure 5 . Windows 95, 98, ME Add New Hardware Wizard 5. During the installation process, it may be required to supply the computer Figure 6 . Windows 2000 New Hardware Wizar d SSP-100 User’s Manual.
with the Windows CD or installation diskettes. The SSP-100 's serial devices will require the file "SERIALUI.DLL". Insert the CD or diskette and click "OK".
4. Open the Properties dialog for the SSP-100 device, then click the Resources tab to view the Input/Output Range and Interrupt Request resource allocations. 5. Use the COM Port device names (COM2, COM4, etc.) to access any of the particular serial ports on the SSP-100 .
Figure 8 . Windows 2000 Device Manager 3 . 2 . 2 Changing Resource Settings with Windows 95, 98, ME Device Manager 1. Start the Windows Device Manager . 2. Double click on the hardware class Ports (Com and LPT) to list hardware devices in the class. 3.
3 . 2 . 3 Changing Resource Setting with Window 2000 Device Manager 1. Start the Windows Device Manager . 2. Double click on the hardware class Ports (Com and LPT) to list hardware devices in the class. 3. The SSP-100 belongs to this hardware class. The device name for the SSP-100 is : Quatech PCMCIA Serial Port.
Figure 9 . Windows 95,98,ME Resource Allocation SSP-100 User’s Manual 3-8.
Figure 10 . Windows 2000 Resource Allocation 5. Several predefined Basic Configurations have been included for the SSP-100 . The SSP-100 can either be forced to use a “standard” base address for COM1 - COM4, or it may be configured to allow Windows to assign the base address.
6. Select a Basic Configuration that displays "No conflicts" in the bottom display region titled Conflicting Device List from the drop down list.
3 . 3 Common Problems Basic Configuration List Not Available: A problem noted on some systems is after a basic configuration has been manually selected is the basic configurations list for the SSP-100 is no longer available.
3 . 4 Installing SSP-100 under Windows NT To allow easy configuration of the DSP-100 the Quatech Device Manager for Windows NT has been written for the hardware. This configuration util i ty supports the DSP-100 only in block addressing mode. To begin the installation, open Windows Explorer and search for the ‘ Setup.
1. Locate and double click the Quatech Device Manager icon on the desktop Device Manager Icon on Desktop SSP-100 User’s Manual 3-13.
2. Click the ‘ Add ’ button at the bottom of the Quatech Device Manager Window. 3. Follow the steps for the ‘ Add Quatech Hardware Wizard ’ . SSP-100 User’s Manual 3-14.
4. Complete the fin al steps of the installation, insert the PCMCIA Card and reboot the computer. v Additional help is available online The PCMCIA PC Card should now be configured. In the future, Windows NT will automatically recognize and configure the DSP-100.
4. Windows CE The Quatech PCMCIA Windows CD installat ion copies a multiple device-specifi c .cab files and the ini file to your desktop computer and launches the Application Manger (which resides on the user's desktop computer as a result of installing Active Syn c) with the Application Manager .
3. The setup program will copy the files to predetermined location, which can be changed by the user. Click next to proceed.. Installation is now complete.
SSP-100 User's Manual 4-3.
5 OS/2 Installation In order to use the SSP-100 Client Driver for OS/2, the system must be configured as follows: 1. The system must be running OS/2 version 2.
5 . 1 Command Line Options The SSP-100 Client Driver for OS/2 supports two methods of configuration: using "system assigned" resources and using "user assigned" resources.
problem if DOS and/or Windows applications will be accessing the serial ports. This is because most DOS applications write directly to the communications hardware and the Windows Control Panel also wants to know the hardware configuration of the serial ports.
5.1.2.2 Example 2 DEVICE=C: SSP-100 SSP 1 00.SYS (7,120,15) (3,300,4) In example 2, the Client Driver will attempt to configure the SSP-100 as COM3 using I/O address 300-3 07 hex and IRQ 4.
5 . 2 Monitoring The Status Of PCMCIA Cards OS/2 Warp provides a utility called "Plug and Play for PCMCIA" that can be used to monitor the status of each PCMCIA socket. In OS/2 version 2.1, this utility is called "Configuration Manager".
(This Page Left Intentionally Blank) SSP-100 User's Manual 4-9.
6. External Connections An adapter cable is included with the SSP-100 to convert the 9-pin PCMCIA output connector into a standard D-9 female connector, data terminal equipment (DTE) , as shown in the figures below. Standard D-9 (Female) Figure 12. SSP-100 Adapter Cable.
(This page intentionally left blank.) SSP-100 User’s Manual 5-2.
7 . Specifications Bus Interface PCMCIA PC Card Standard 2.1 compliant Physical Dimensions Type II PCMCIA card (5mm) Maximum Baud Rate 120K Power Requirements +5 volts 1 8.
SSP-100 User's Manual Revision 2.30 September, 2001 P/N 940-007 4 - 230.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Quatech SSP-100 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Quatech SSP-100 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Quatech SSP-100, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Quatech SSP-100 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Quatech SSP-100, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Quatech SSP-100.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Quatech SSP-100. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Quatech SSP-100 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.