Manuel d'utilisation / d'entretien du produit MS3580 du fabricant Quantum Instruments
Aller à la page of 56
METROLOGIC INSTRUMENTS, INC. MS3580 Quantum T ™ Installation and User's Guide.
Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any for m or by any means without prior written consent, except by reviewer, who may quote br ief passages in a review, or provided for in the Copyright Act of 1976.
ii T ABLE OF C ONTENTS Introduction Product Over view ............................................................................................. 1 Scanner and A ccessori es ...........................................................................
iii T ABLE OF C ONTENTS Troubleshootin g Guid e ....................................................................................... 27 Design Specif icati ons ........................................................................................
1 I NTRODUCTION The Quantum T ™ is a hands-free, omni directional bar code scann er with optional single-line scanning capab ilities. It utiliz es the powerful Metrologic Quantum E ™ scan engine to provide an out standing scan performance o n all standard 1D barcode symbologies, inclu ding RSS.
2 I NTRODUCTION Scanner and Accessories B ASIC K IT C OMPONENTS Part No. Description MS3580 Quantum T Omni Single-Line Scanner 00-02026 Quantum T Omni Single-Line Scanner Installation and User’s Guide * 00-02407 MetroSelect ® Confi guration Guide * * Guides also available for dow nload at www.
3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part No. Description 54-54002x-3 Keyboard Wedge Po werLink Cable 2.1 m (7 ft.) straight co rd, short strain relief 54-54020x-3 Stand Alone Keyboard Po werLink Cable 2.
4 I NTRODUCTION Scanner Components Figure 1. Scanner Components I TEM N O . D ESCRIPTION 1 Red Output Window (Laser Aperture) 2 Pin Hole for Cable Release 3 10-Pin RJ45, Female Socket 4 Speaker 5 Blue and White LED Indicators 6 Button 7 Protective Boot and Stand Connection Never remove the protective boot from the MS3580.
5 I NTRODUCTION Caution and Serial Number Labels Figure 2. Cable Removal 1. Locate the small ‘pin-hole’ o n the side of the Quantum T near the cable. 2. Bend an ordinary paperclip i nto the shape shown. 3. Insert the paperclip (or other small metallic pin) into the small ‘pin-hole’.
6 I NTRODUCTION Mounting Specifications and Stand Assembly Pedestal Stand Figure 4. Pedestal Stand Assembly Optional Flex Stand Figure 5. Assembly Components for Optional Flex Stand Item Description Qty. Item Description Qty 1 MS3580, Quantum T 1 6 Flexible Shaft* 1 2 Pivot Cylinder 1 7 Base Plate Cover 1 3 Bearing Plate 1 8 #8 x 1.
7 I NTRODUCTION Mounting Specifications and Stand Assembly Optional Flex Stand Figure 6. Mounting Hole Detail for the Flex Stand Base Plate (Opti onal) Figure 7.
8 I NSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS3580. 3. Connect the 9-pin female end of the PowerLink cable to the host device.
9 I NSTALLATION IBM 46xx or OCIA 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS3580. 3.
10 I NSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS3580. 3. Disconnect the keyboard from the host device. 4. Connect the “Y” end of the PowerLink cable to the keyboar d and the keyboard port on the host PC.
11 I NSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS3580. 3. Connect the other end of the PowerLink cable to the keyboard port on the host device. 4.
12 I NSTALLATION Full Speed or Low Speed USB 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the MS3580. 3. Plug the other end of the USB interface cable into the host device’s USB port. 4. Turn on the host device.
13 S CANNER O PERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable sc an pattern modes available with the MS3580. • The primary scan pattern mode is the default scan pattern active when the scanner starts.
14 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON C LICK M ODE WITH C ODE G ATE E NABLED For illustration purposes the unit’s primary sc an pattern has been set .
15 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON C LICK M ODE WITH C ODE G ATE D ISABLED For illustration purposes the unit’s primary sc an pattern has been set.
16 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON H OLD M ODE WITH C ODE G ATE E NABLED For illustration purposes the unit’s* primar y scan pattern has been set .
17 S CANNER O PERATION Configurable Button Functions 5. To scan and transmit additional bar codes, repeat steps 2 through 4. 6. The primary scan pattern will automatically reactivate after the button is released and no bar code is present in the scan field.
18 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON H OLD M ODE WITH C ODE G ATE D ISABLED For illustration purposes the unit’s* primar y scan pattern has been set.
19 S CANNER O PERATION Audible Indicators When the MS3580 is in operation, it pr ovid es audible feedback to indic ate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone).
20 S CANNER O PERATION Visual Indicators The Quantum T is equipped with a blue and white LED that indic ates the scanner’s state and the status of the current scan wh en the unit is in operation.
21 S CANNER O PERATION Failure Mode Indicators Flashing Blue a nd One Razzberry Tone This indicates that the scanner has experien ced a laser subsystem failure. Return the unit to an authoriz ed service center for repair. Flashing Blu e and White and Tw o R az z b e rr y Tones This indicates that the scanner has experien ced a motor failure.
22 S CANNER O PERATION Depth of Field Specifications* Normal Scan Zone Specifications are based o n a 0.33 mm (13 mil) bar code. Figure 14. MS3580 † Normal Dept h of Field * All specifications are subj ect to change w ithout notice. † MS3580 shown with pedestal stand.
23 S CANNER O PERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based o n a 0.33 mm (13 mil) bar code. Figure 15. MS3580 † Reduced De pth of Field * All specifications are subj ect to change w ithout notice. † MS3580 shown with pedestal stand.
24 S CANNER O PERATION Depth of Field by Bar Code Element Width* Normal Scan Zone M INIMUM B AR C ODE E LEMENT W IDTH A B C D E F mm .13 .15 .19 .25 .33 .66 mils 5.2 5.7 7.5 10 13 26 Figure 16. Normal Scan Zone by Bar Code Element W idth * All specifications are subj ect to change w ithout notice.
25 S CANNER O PERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone M INIMUM B AR C ODE E LEMENT W IDTH A B C D E F mm .13 .15 .19 .25 .33 .66 mils 5.2 5.7 7.5 10 13 26 Figure 17. Reduced Scan Zone by Bar Code Ele ment Width * All specifications are subj ect to change w ithout notice.
26 S CANNER O PERATION IR Activation Range* Quantum T ‘s default power save mode † is Laser OFF . This power save mode turns the laser off after a configured per iod of non-us e. Any movement detected by the IR in the activation area will cause the scanner to exit power save mode.
27 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-MET RO or 1- 800-436-3876 to preserve the l imited warranty terms on page 46. Symptoms Possible Cause(s) Solution All Interfaces The unit has no LEDs, beeper or motor spin.
28 T ROUBLESHOOTING G UIDE Symptoms Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan ( the white LED stays on ). The scanner is configured to support some form of host handshaking but is not receiving the signal.
29 T ROUBLESHOOTING G UIDE Symptoms Possible Cause(s) Solution All Interfaces During power up the unit beeps 3 times. There is a non-volatile RAM failure. Contact a Metrologic service representative. During power up the unit razzes continuously. There is a RAM or ROM failure.
30 T ROUBLESHOOTING G UIDE Symptoms Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanner and host may not be configured for the same interface. Check that the scanner and the host are configured for the same interface.
31 D ESIGN S PECIFICATIONS MS3580 Operational Light Source: V isible L aser D iode (VLD) @ 650 nm Laser Power: 1.1 mW Normal Depth of Field: 19 mm - 273 mm (.75" - 10.75") Reduced Depth of Field: 19 mm - 146 mm (.75" - 5.75") 0.33 mm (13 mil) bar code Omni Scan Scan Speed: 1650 scan lines per second No.
32 D ESIGN S PECIFICATIONS MS3580 Mechanical Width: 63 mm (2.48") Depth: 50 mm (1.97") Height: 68 mm (2.68") Weight: 6 oz (170 g) Electrical Voltage Supply: 5VDC ± 0.25V Operating Power: 1.375 W Standby Power: 1.0 W Operating Current: 275 mA typical at 5VDC Standby Current: 230 mA typical at 5VDC DC Transformers: Class II; 5.
33 A PPLICATIONS AND P ROTOCOLS The model number on each scann er includes the scanner number a nd factory default communications proto col. S CANNER V ERSION I DENTIFIER C OMM UNIC ATION P ROTOCOL ( .
34 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS Many functions of the scanner can be "config u red" - that is enabled or disabled. The scanner is shipped from the factor y c onfigured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages.
35 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT OCIA USB RS232* OR RS232 TTL L IGHT P EN IBM 46XX KBW L ASER E MULATION Expanded ID “]e0” * RSS L.
36 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT OCIA USB RS232* OR RS232 TTL L IGHT P EN IBM 46XX KBW L ASER E MULATION Transmit UPC-A Check Digit * .
37 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT OCIA USB RS232* OR RS232 TTL L IGHT P EN IBM 46XX KBW L ASER E MULATION Nixdorf ID LRC Enabled UPC Prefix.
38 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT OCIA USB RS232* OR RS232 TTL L IGHT P EN IBM 46XX KBW L ASER E MULATION Supplements are not Required * .
39 U PGRADING THE F LASH ROM F IRMWARE The MetroSet2 program is a functional c omponent of Metrologic’s ne w line of Flash- based scanners. T his program allo ws the user of a Metrologic scanner to quickly upgrade to a ne w or custom version of firmware.
40 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections The MS3580 scanner interfaces terminate to a 10-pin modular socket. The serial # label indic ates the interface enabled when the scanner is shipped from the factory.
41 S CANNER AND C ABLE T ERMINATIONS MS3580- 11 IBM 468X/469 X MS3580- 9 OCIA Pin Function Pin Function 1 Ground 1 Ground 2 RS232 Transmit Output 2 RS232 Transmit Output 3 RS232 Receive Input 3 RS232 .
42 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable MLPN 54-54000 x -3 straight Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 R.
43 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge Po werLink Cable 54-54002 x -3 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5.
44 L ASER AND P RODUCT S AFETY Caution Use of controls or adjustments or performanc e of procedures othe r than those specified herein may result in hazardous laser light ex posure. Under no circumstances should the customer attempt to service the laser scanner.
45 L ASER AND P RODUCT S AFETY Notices This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rules. T hese limits are designed to provide reasona ble protection against harmful interference when the equipment is operated in a comme rcial environment.
46 L IMITED W ARRANTY The MS3580 Quantum T ™ scanners are manufactured by Metrologic at its Bla ckwood, New Jersey , U.S.A. facility . The MS3580 Quantum T scanners have a th ree (3) year limited warranty from the d ate of manufacture.
47 P ATENTS Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.; 5,216,232; 5,260,553; 5,340,971; 5,424,525; 5,484,992; 5,525,789; 5.
48 I NDEX A AC ....................................... 2, 8–12 Accessories ............................... 2, 3 Adapter ........................................ 10 Audible Indicato r ............. 13, 19–21, 27–30, 39 B Bar Code ............. 19–21, 27–30, 31 Bar Widt h.
49 I NDEX MetroSet 2 .................................... 39 Mode of Operation Button ...................................... 18 Primary .............................. 13–18 Secondar y .......................... 13–18 Sweet Spot Mode ..............
50 C ONTACT I NFORMATION AND O FFICE L OCATIONS C ORPORATE H EADQUA RTERS N ORTH A MERICA E UROPEAN , M IDDLE E AST & A FRICAN H EAD QUA RTER S USA, New Jerse y Germany, Mu nich Metrologic Instruments, Inc. Metrologic In struments GmbH Tel: 1-800-ID-METRO Fax : 856-228-6673 Tel: 49-89-89019 -0 Fax: 49-89-8901 9-200 Email: info@metrologic.
.
June 2005 Printed in the USA 00 - 05090B.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Quantum Instruments MS3580 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Quantum Instruments MS3580 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Quantum Instruments MS3580, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Quantum Instruments MS3580 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Quantum Instruments MS3580, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Quantum Instruments MS3580.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Quantum Instruments MS3580. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Quantum Instruments MS3580 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.