Manuel d'utilisation / d'entretien du produit 560UF/D du fabricant Quantum
Aller à la page of 45
P rofessional External M odem USER'S MANUAL 560UF/L & 560UF/D External Modem QUANTUM DATA SYSTEMS (HK) LTD..
ACTIVE P rofessional External M odem USER` S MANUAL For Models: 560UF/L & 560UF/D The contents of this manual are subject to change without prior notice.
WARNING - AUSTRALIAN USERS This FAX/Modem has been tested with Bitcom, Bitware for windows and fully complies with AUSTEL Technical Standards if the following conditions are followed : 1 THE NUNMBER OF RE- DIAL MUST NOT BE SET TO GREATER THAN 3 2.
TABLE OF CONTENTS CHAPTER 1. INTRODUCTION 1 CHAPTER 2. INSTALLATION 2 CHAPTER 3. LEASED LINE OPERATION 9 APPENDIX A. AT COMMANDS 11 APPENDIX B. RESULT CODES 24 APPENDIX C. S REGISTERS 26 APPENDIX D. CABLE PINS ASSIGNMENT 36 APPENDIX E. SPECIFI CATIONS 37 APPENDIX F.
CHAPTER 1. INTRODUCTION ACTIVE Professio n al External Modem User ’ s Manual 1 CHAPTER 1. INTRODUCTION OVERVIEW Congratulations on your purchase of ACTIVE Professiona l Externa l Modem. The modem equip s with V.42/MNP2-4 error control, V.42bis/MNP5 data compression as well as 14400bps facsimile functions.
CHAPTER 2. INSTALLATION ACTIVE Professio n al External Modem User ’ s Manual 2 CHAPTER 2. INSTALLATION Carefully unpack the product package that you have received and check the contents as following.
CHAPTER 2. INSTALLATION ACTIVE Professio n al External Modem User ’ s Manual 3 THE FRONT PANEL : 560UF/L & 560UF/D External Modem The front panel consists of seven light indicators, a 7 segment .
CHAPTER 2. INSTALLATION ACTIVE Professio n al External Modem User ’ s Manual 4 A 7-segment LED (optional) Monitor the line speed . The speed may fall down or step up depending on the telephone line quality.
CHAPTER 2. INSTALLATION ACTIVE Professio n al External Modem User ’ s Manual 5 a. If the modem is in Normal mode, it acts as a O/A switch. Toggle this switch causes the modem to change from Originate mode to Answer mode and the LED segment displays ‘ A.
CHAPTER 2. INSTALLATION ACTIVE Professio n al External Modem User ’ s Manual 6 Modem Configuration Table (Further reference: Appendix G) Menu (0-C, set by Menu switch) 0 Factory default - &F function (set by switch) ( 0)Auto ,(1)MNP,(2)Direct Mode.
CHAPTER 2. INSTALLATION ACTIVE Professio n al External Modem User ’ s Manual 7 8 Smart/Dumb mode - &A function (0) smart, (1) dumb 9 Compression control - %C function (0) Enables both MNP5 and V.42bis data compression (1) Disables data compression (2) Enables MNP5 data compression (3) Enables V.
CHAPTER 2. INSTALLATION ACTIVE Professio n al External Modem User ’ s Manual 8 Example to set up DTE speed 57600 bps and modulation V.22 bis, 1. Set Normal / Config.
CHAPTER 3. LEASED LINE OPERATION ACTIVE Professio n al External Modem User ’ s Manual 9 CHAPTER 3 . LEASED LINE OPERATION This chapter tells you how to establish a leased line connection in asynchronous and synchronous modes.
CHAPTER 3 . LEASED LINE OPERATION ACTIVE Professio n al External Modem User ’ s Manual 10 Then press the Enable Switch to update the DTE speed, The character ‘ U ’ is shown on the LED segment. If more setting are required ( i.e transmission mode, flow control, etc), repeat the above procedures.
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 11 APPENDIX A. AT COMMANDS The PC or terminal communicates with the modem through the use of the AT commands. Your communication software will act as an interface between you and your modem.
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 12 +++ Escape Characters Default : + Switch the modem from Online State to Command State without breaking the data connection. This character can be redefined by changing the value in S Register S2.
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 13 A-D DTMF digits A ,B,C and D. These digits may be prohibited in some countries * The "star" digit (tone dial.
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 14 ATLn * Speaker volume Default : 2 ATL0 Selects low speaker volume ATL1 Selects low speaker volume ATL2 Selects medium .
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 15 ATT * Set tone dial as default ATVn * Result code form (message control) Default : 1 ATV0 Allows short form (numeric) .
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 16 a handshaking sequence, the call and answer can be aborted by receiving any character from DTE.
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 17 AT&K4 Enables XON/XOFF flow control AT&K5 Enables transparent XON/XOFF flow control AT&K6 Enables both RTS.
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 18 AT&T0 Ends test in progress AT&T1 Initiates loc al analog loopback AT&T3 Initiates remote digital loopback locally. If no connection exists, ERROR is returned.
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 19 ATAn Maximum MNP block size Default : 2 ATA0 Sets maximum block size to 64 characters ATA1 Set s maximum block size to.
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 20 ATK2,3 Modem does not clear buffers but sends a break to the local DTE ATK4,5 Modem sends a break in sequence with any.
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 21 002 = Received level of -2dBm . . . . 43 Received level of -43dBm AT%On * Selects answer/originate mode Default : 1 %O.
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 22 Distinctive ring type Ring Cadence Detect Criteria 1 2.0 sec ON, 4.0 sec OFF. 2 0.8 sec ON, 0.4 sec OFF, 0.8 sec ON, 4.0 sec OFF. 3 0.4 sec ON, 0.2 sec OFF, 0.4 sec ON, 0.
APPENDIX A. AT COMMANDS ACTIVE Professio n al External Modem User ’ s Manual 23 <mod > Modulation Selected Possible Rates (bps) < min _rate>, < max_rate> 0 V.21 300 1 V.22 1200 2 V.22 bis 2400 or 1200 3 V.23 1200 9 V.32 9600 or 4800 10 V.
APPENDIX B. CABLE PINS ASSIGNMENT ACTIVE Professio n al External Modem User ’ s Manual 24 APPENDIX B. RESULT CODES ACTIVE modem responds to commands from the DTE and to activity on the line by signalling to the DTE in the form of result codes. The result codes can be sent by the modem in either short from (terse) or long form (verbose).
APPENDIX B. CABLE PINS ASSIGNMENT ACTIVE Professio n al External Modem User ’ s Manual 25 185 CONNECT 37333 186 CONNECT 38667 187 CONNECT 41333 188 CONNECT 42667 189 CONNECT 45333 190 CONNECT 46667 .
APPENDIX C. S REGISTERS ACTIVE Professio n al External Modem User ’ s Manual 26 The symbol * means register value may be stored in one of the two user profiles with the AT&Wn command. Register parameter ranges from 0 - 255 unless specified. APPENDIX C.
APPENDIX C. S REGISTERS ACTIVE Professio n al External Modem User ’ s Manual 27 S6 * Wait time for blind dialling (Range :2-255) Default : 2 Sets the lengt h of time in seconds to pause after the modem goes off- hook and before the modem dials the first digit of the telephone number.
APPENDIX C. S REGISTERS ACTIVE Professio n al External Modem User ’ s Manual 28 S14 * Bit mapped option Bit 0 0 ATT (Default) 1 ATP Bit 1 0 ATE0 1 ATE1 (Default) Bit 2 0 ATQ0 (Default) 1 ATQ1 Bit 3 .
APPENDIX C. S REGISTERS ACTIVE Professio n al External Modem User ’ s Manual 29 S18 * Test timer Default : 0 Sets the length of time in second which the modem conducts a test before returning to the command mode.
APPENDIX C. S REGISTERS ACTIVE Professio n al External Modem User ’ s Manual 30 5 ATX2 6 ATX3 7 ATX4 Bit 7 Reserved S23 * Bit mapped options Bit 0 0 AT&T5 1 AT&T4 Bit 1-3 Local DTE rate 0 0-.
APPENDIX C. S REGISTERS ACTIVE Professio n al External Modem User ’ s Manual 31 register sets the time delay in hundredth of a second before the modem turns CTS ON.
APPENDIX C. S REGISTERS ACTIVE Professio n al External Modem User ’ s Manual 32 S31 * Bit mapped option Bit 0 Reserved Bit 1 0 ATN0 1 ATN1 Bit 2,3 0 ATW0 1 ATW1 2 ATW2 Bit 4-7 Reserved S32 XON Chara.
APPENDIX C. S REGISTERS ACTIVE Professio n al External Modem User ’ s Manual 33 9 Attempts to connect at 9600bps 10 Attempts to connect at 12000bps 11 Attempts to connect at 14400bps 12 Attempts to .
APPENDIX C. S REGISTERS ACTIVE Professio n al External Modem User ’ s Manual 34 S42 - S45 Reserved S46 * Data compression control (Range :136,138) Default : 138 136 Executes error correction protocol with no comp ression 138 Executes error correction protocol with compression S48 * V.
APPENDIX C. S REGISTERS ACTIVE Professio n al External Modem User ’ s Manual 35 Sets the transmit level from 0 to -15 dBm for the FAX mode. The value may be limited as it is a country dependent parameter.
APPENDIX D. CABLE PINS ASSIGNMENT ACTIVE Professio n al External Modem User ’ s Manual 36 APPENDIX D . CABLE PINS ASSIGNMENT For 560UF/L and 560UF/D External Modem Pin EIA V.24 Abbrev. Function 1 CF 109 C D Carrier Detect 2 BB 104 R D Receive Data 3 BA 103 T D Transmit Data 4 CD 108.
APPENDIX E. SPECIFICATIONS ACTIVE Professio n al External Modem User ’ s Manual 37 APPENDIX E . SPECIFICATIONS Compatibility: Data modem: ITU-T V.90, K56fl ex (560 models only), V.34+, ITU-T V.34 , ITU-T V.32bis, ITU-T V.32, ITU-T V.22bis, ITU-T V.23, ITU-T V.
APPENDIX E. SPECIFICATIONS ACTIVE Professio n al External Modem User ’ s Manual 38 Transmit Level: -10 dBm (Country dependent) Receive Sensitivity: -43dBm / -33dBm (336 models only) Command Buffer: .
APPENDIX F APPLICATION EXAMPLES ACTIVE Professio n al External Modem User ’ s Manual 39 APPENDIX F . APPLICATION EXAMPLES.
40 <-------------------------------------------- -------------------------------------------------------------------- ---------------------- - F unction s ---------------------------- -------- ----.
40.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Quantum 560UF/D c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Quantum 560UF/D - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Quantum 560UF/D, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Quantum 560UF/D va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Quantum 560UF/D, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Quantum 560UF/D.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Quantum 560UF/D. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Quantum 560UF/D ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.