Manuel d'utilisation / d'entretien du produit 150-08ACW-134 du fabricant Quantum
Aller à la page of 40
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s OWNER'S MANUAL D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 o f 4 0 Including Installation Instruc tions And .
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 o f 4 0 Contents Sec tio n 1: APP LIAN CE D ETA ILS ....................................................................
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 o f 4 0 4c: Caution W hen Left Op erating But Unused....................................................................
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 4 o f 4 0 10b.2: Second Level: Press SE T+DOWN for 6 seconds .......................................................... 26 10b.
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Section 1: APPL IANCE DETA ILS For future convenience, please fill in the following details and retain with your original invoice. 1a: Owner’s Details Surname: …………………………………… Given Name(s): ….
Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Sectio n 2: INTR ODUCTION Quantum Energy Technologies 2a: One Of The Worlds Most Energy Efficient Methods Of Wa ter Heating Producti.
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s 2c: Features Of Your Quantum Wat er Heat er 1. Fully welded steel tank with class X vitr eous enam el lining for superior corrosion resistance and longer life. 2. Indirect heat transfer eliminates tank hot spots.
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 8 o f 4 0 3a.2: Corrosion Protection Fittings and the Shell Surface in contact with the wa ter are to be galvanica lly comp atible.
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 9 o f 4 0 3f: Cold Water Connection An approved isolating valve, appr o.
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 0 o f 4 0 3m: Electrical Connection Quantum water heaters are designed for singl e-phase 220/240V A.
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s 3n.1: Refrigeration Tube Siz es Quantum Model Copper Tube Siz e - Inlet Copper Tube Size - Outlet 340 TIH-134 3 / 8 Inch (9.5mm ) 5 / 8 Inch (15.9mm ) * When the evaporator is below the tank level on the Titan model use 12.
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Figure 1: Installation Diagram (Compact Systems) D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 2 o f 4 0 Orie ntat ion if multiple Com pact units are Condensation Drain Power Cord 100 m m Mi n Wal l 500 m m Min be ing ins talled .
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Figure 2: Installation Diagram (Split Systems) D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 3 o f 4 0 Power Connec.
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Section 4: OPERAT ING INSTRUCTIONS 4a: Filling The Water Heater Open all hot water taps. Open isolating valve at th e cold-wa ter inlet and allow the water heater to fill until water flows through the system .
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s 5b: Important Note Regarding PTR Valve The Pressure & Temperature relief valve should be checked for adequate perform ance or replaced at intervals not exceeding 5 years, or less in areas where there is a high incidence of water deposits.
Owner’ s Manual Quantum Energy T echnologies 6d: Ser vice Ca ution – Bef ore Any Work Is Carried Out Before any electrical components are inspected the System MUST be turned off at the power switch / hot water circuit breake r.
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 7 o f 4 0 6f.2: Five Year Service (By Authorized Personnel Only) The five-year service should be carried out by a li censed tradesperson every five years.
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 8 o f 4 0 6f.4: Flushing Of Water Tank As with other hot water heater tanks, dissolved solids in the water or scale m ay accum ulate in the bottom of the water tank form ing sludge.
Owner’ s Manua l Q u a n t u m Energy T echnologies Section 7: RECOGNITION OF ABNORM AL OPERATION 7a: Pressure & Temperatu re Relief Valve Running It is not unusual for the Pressure & Tem perature Relief valve to allow a small quantity of water to escape during the heating cycle.
Owner’ s Manua l Q u a n t u m Energy T echnologies D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 0 o f 4 0 4. Replace faulty tap washers and have your plumber rectify any leaking pipe work. 5. Have any new appliances been instal led that might be using the extra power? 6.
Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Section 8: WARRANTY CERTIFICATE QUANTUM HOT WATER UNIT MANUFACTURE D BY QUANTUM ENERG Y TECHNOLOGIES PTY LTD Terms Of Warranty QUANTU.
Owner’ s Manua l Quantum Energy T echnologies D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 2 o f 4 0 8a: Items Not Covered By Warranty □ Service calls due to: • Dirty Filters. • Blown Fuses • Incorrect Operation. • Tripped Circuit Breakers.
Owner’ s Manual Q u a n t u m Energy T echnologies D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 3 o f 4 0 Section 9: SPECIFICATIONS Tanks are Dual Entry, Fully W elded w ith Class X Vitreous Ena m el lining.
Owner’s Manual Quantum Energy T echnologies Figure 4: Split Fin Coil Evaporator – 340 TIH-134 D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 4 o f 4 0 635 400 500 3 / 8 ” Discha.
Owner’ s Manua l Quantum Energy T echnologies Section 10: OPERATION & ADJUSTMENT OF TH E DIGITAL CONTROLLER Caution: Alteration of the Digital Controllers progr amm ing & settings without authorisation fro m Quantum Energy T echnologies will void your warranty .
Owner’ s Manua l Quantum Energy T echnologies D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 6 o f 4 0 10b.1: First Level: Press SET + UP for 6 Seconds t10 Compressor start time delay; 1 to 30 m in adjustable. Factory setting 10 min.
Owner’ s Manua l Quantum Energy T echnologies D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 7 o f 4 0 10d: De-Icing Only if the temperature, measured by the evaporator sensor , is below 0 ℃ will the de-icing function operate.
Owner’s Manual Quantum Energy T echnologies Figure 5: Layout Of Digital Controller Programming Buttons D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 8 o f 4 0 LCD Display Up But to.
.
.
Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Appendix A: TROUBLE SHOOTING GUIDE ON QUANTUM WATER HEATERS Models covered in this guide : 800 W att. Compact Air Sourced Dom estic Hot W ater Heater (0.8kW compressor m odels) 1100 W att.
Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 2 o f 40 A.2: Thermal Cut Out Trips Off Repeatedly Probable Cause Test / Observation Action 1. Low refrigerant charge. Check refrigerant ch arge.
Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 3 o f 40 A. 3: No Hot Water; Compressor Running Probable Cause Test / Observation Action 1. Tank water drawn off - unit only recently started.
Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s A.5: Testing Undercharge Or Overcharge Of Refrigerant Unlike normal refrigerating or air condition ing systems, the QUANTUM heat pum p operates under a very wide range of evaporating and condensing temp eratures.
Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 5 o f 40 A.8: Signs Of Correct Charge During normal operation with the correct am o unt of refrigerant gas, the sight glass should show clear liquid.
Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 6 o f 40 A.11: Technical Data Fo r Service Person nel – SIAM Compressors – R134a Parameters 150-08ACW-134 270 & 340-11AC3-134 340TIH-134 340-17ACW-134 Superheat setting 1.
Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s WARRANTY CARD Warranty Registered (Office Use Only) □ P r o d u c t M o d e l : S e r i a l N u m b e r : D a t e M a n u f a c t .
Owner’ Manual Quantum Energy T echnologies BLANK PAGE D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 8 o f 4 0.
Owner’ Manual Quantum Energy T echnologies NOTES (Own er’s Use) D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 9 o f 4 0.
MANUFACTURED BY QUANTUM ENERGY TE CHNOLOGIES PTY LTD 56-60 Bourke Road Alexandria NSW 2015 Phone: (02) 4953 9888 Fax (02) 4953 9887 A.B.N: 88 095 959 327 NOTE: Every care has been taken to ensure th e accuracy in preparing this publication. No liability can be accepted for any consequences, which m ay arise as a re sult of its application.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Quantum 150-08ACW-134 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Quantum 150-08ACW-134 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Quantum 150-08ACW-134, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Quantum 150-08ACW-134 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Quantum 150-08ACW-134, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Quantum 150-08ACW-134.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Quantum 150-08ACW-134. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Quantum 150-08ACW-134 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.