INSTRUCTION MANUAL BEDIENUNGSANLEITUNG MANUEL D’INSTRUCTIONS VCC-5775P COLOUR CCD camera CCD-Farbkamera Caméra CCD COULEUR CCD About this manual Befor e installin g and using the camer a, please read this manual carefully. Be sure to keep it handy for later reference.
Depending on the conditions of use, installation and environment, please be sure to make the appropriate settings and adjustments. If you need help with installation and/or settings, please consult your dealer. CONTENTS PRECAUTIONS ...................
FEATURES • Built-in interline transfer method 1/3" CCD, approx. 470,000 picture elements • Low smear, anti-blooming, low lag, no burning and no geometric distortion using the CCD solid state image device.
PRECAUTIONS In case of problem Do not use the camera if smoke or a strange odour comes from the unit, or if it seems not to function correctly. Disconnect the power cord immediately, and consult your dealer (or a Sanyo Authorized Service Centre). Do not open or modify Do not open the cabinet, as it may be dangerous and cause damage to the unit.
PRECAUTIONS Protect from high temperatures Do not install close to stoves, or other heat generating devices, such as spotlights, etc., or where it could be subject to direct sunlight, as that could cause deformation, discoloration or other damages.
PARTS NAMES 1 Camera mounting screw hole CAUTION: When installing the camera, select a location that can support the total weight of the camera and accessories.
PARTS NAMES 7 Flange-back lock screw 8 CS mount ring 9 Lens mount cap The cap is installed to protect the lens mount section. Remove the lens mount cap before installing a lens. F Video output connector (VIDEO OUT: BNC type) Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector.
MOUNTING THE LENS Please use a DC type auto-iris lens (sold separately). Checking the lens mount Do not use lense with a length L more than 5 mm. If not, that may damage the camera and prevent proper installation. 1 Remove the lens mount cap from the camera.
MOUNTING THE LENS Pin layout 1 Brake coil (–) 2 Brake coil (+) 3 Drive coil (+) 4 Drive coil (–) Rewiring the lens cable in the lens iris plug 1 Prepare the lens cable. Cut t he c a ble at the plug, t hen r emove approx. 8 mm of the cable shea t h and stri p a b out 2 mm from e a ch wi re.
CONNECTIONS Basic connection for monitoring or recording (Video signal connections) : VIDEO IN : VIDEO OUT AC 24 V connection DC 12 V connection Fig. 1 Fig. 2 + – + DC12V – Push to insert the cable. Note: The polarities for the 24 V AC and the 12 V DC input connectors are indicated on the rating label found on the unit back panel.
CONNECTIONS The peripheral devices (VCR, monitor, lens, etc.) and cables are sold separately. 1 Make the video signal connection between the camera and the monitor or timelapse VCR. 2 Power supply choices • Use a commercially available 24 V AC adaptor.
FLANGE-BACK ADJUSTMENT If the pick-up surface is not correctly positioned with relation to the lens focal point, the picture will be out of focus ( in particular when using auto-iris power zoom lenses, sold separately ). If that is the case, adjust the flange-back position as described below.
SETTINGS Line phase adjustment When using a camera switcher to connect 2 cameras or more to one monitor, there may be a vertical roll of the images when switched. In such a case, set as described below. 1 Set the Sync switch to the L-L position. 2 Switch the display on the monitor from camera 1 to camera 2.
SETTINGS Lens iris adjustment If using a DC type auto-iris lens, you will need to set the LEVEL volume when shooting in the conditions described below. Counterclockwise: To decrease the brightness Clockwise: To increase the brightness • If shooting simultaneously in a dark room and through a bright window.
SETTINGS EI (Electronic iris) function setting Under normal conditions, set the EI switch to the EI OFF position and use an auto-iris lens. However, if you have a manual lens or fixed iris lens, set the lens aperture to the shortest F stop and set the EI switch to the EI ON position.
TROUBLESHOOTING Before tak ing t he camer a for r epairs, p lease c hec k below to make su re that t he ca mera is used cor rectly. If it still does not perform correctl y , p lease cons u lt you r deale r or a Sany o Authori zed Ser v i c e Ce ntre.
SPECIFICATIONS Scanning system: PAL standard (625 TV lines, 25 frames/sec.) Interlace: 2:1 interlace Image device: 1/3 in ch s olid s tate image device C C D Picture elements: 798 (H) x 584 (V) Effect.
SPECIFICATIONS Dimensions: mm Features and specifications are subject to change without prior notice or obligations. 51 63 68 (1) L53V2/ XE (VCC -5775P ) GB 2000, 7 , 11 English 17.
ACCESSORIES 12 1 C mount adaptor (5 mm) ........................ 1 pc. The C mount adaptor must be used to be able to install a C mount lens on the camera.
1AC6P1P2347-- L53V2/XE(0700KP-DSP) Sanyo Electric Co, Ltd. Printed in Japan L53V2/ X E (VCC -5775P) GB 2 000, 7, 11.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Proxima ASA VCC-5775P c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Proxima ASA VCC-5775P - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Proxima ASA VCC-5775P, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Proxima ASA VCC-5775P va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Proxima ASA VCC-5775P, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Proxima ASA VCC-5775P.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Proxima ASA VCC-5775P. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Proxima ASA VCC-5775P ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.