Manuel d'utilisation / d'entretien du produit 831.21005 du fabricant ProForm
Aller à la page of 24
Patent Pending USER'S MANUAL A pH testing kit (not included) is required for proper use and maintenance of this product. A pH testing kit can be pur- chased at any spa or pool supply store. CAUTION Read all precautions and instruc- tions in this manual before using this equipment.
T ABLE OF CONTENTS IMPORT ANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 BEFORE YOU BEGIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 IMPORT ANT SAFETY INSTRUCTIONS W ARNING: TO REDUCE THE RISK OF DROWNING, ELECTRIC SHOCK, OR SERIOUS INJUR Y , READ THE FOLLOWING IMPORT ANT PRECAUTIONS BEFORE USING THE RESTORA TION 5.
4 20. DANGERÑIf you will be using the hydrother- apy spa outside, do not bury the power cord; you should also keep the power cord away from lawn mowers, hedge trimmers, and other similar equipment. 21. W ARNINGÑThe hydrotherapy spa must be wired directly into a 240 volt power source equipped with a Ground Fault Circuit Interrupter (GFCI).
5 34. W ARNINGÑT o reduce the risk of injury or drowning: Consult your physician about pos- sible side-effects of any medications you may be taking before using the hydrotherapy spa. Heat from the water , in conjunction with some medications may cause drowsiness and increase the risk of drowning.
6 BEFORE YOU BEGIN Thank you for selecting the innovative PROFORM ¨ RESTORA TION 5.1 hydrotherapy spa. The RESTORA TION 5.1 hydrotherapy spa of fers the fea- tures and quality of a traditional hot tub at an afford- able price. Best of all, the RESTORA TION 5.
7 CHOOSING A LOCA TION FOR THE HYDROTHERAPY SP A There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you use the hydrotherapy spa inside or outside. We have listed several factors you may wish to consider as you decide where you want to use the hydrotherapy spa.
8 SET -UP AND ASSEMBL Y Before beginning assembly , carefully read the following information and instructions: ¥ Place all parts in a cleared area and remove the packing materials from the spa shell; do not dis- pose of the packing materials until assembly is completed and the spa is in operation.
4. The RESTORA TION 5.1 is designed to operate with a 240 volt power source and must be wired directly to a 240 volt ground fault circuit interrupter (GFCI) installed in your home.
1. Remove the two indicated Control Unit Screws (19) and the two Small Star W ashers (8) from the cover on the Control Unit (14). Fold the cover down. Route the 240 volt AC power cord through the indi- cated opening on the right side of the Control Unit (14).
11 5. For a 40 amp 240 volt AC power supply , set the jumper J1 to pins 1 and 2 on the power board and leave the other jumpers at the factory settings, as shown at the right. This will allow the heater and the pump to operate at high speed simultaneously .
12 USING THE HYDROTHERAPY SP A The hydrotherapy spa is designed to seat five adults. The fifteen thera-jets can be regulated to provide a relaxing massage to sooth away stress, and the strength of the water massage can be adjusted by the air control.
13 A A B B D C A E A D A B SP A SHELL DIAGRAM SP A OPERA TION Refer to the diagram above. The function of each component is explained below: The eight uni-directional thera-jets (A) are located on both sides of the spa. Five jets focus the water massage on your upper or lower back.
14 USING THE CONSOLE Refer to the console diagram above. The function of each console control is explained below: T emperature Display: During normal use this display shows the actual water temperature. When the Set T emp indicator is lit, the display shows the set temperature.
15 POSTING THE W ARNING SIGN The warning sign, shown below , must be posted on a wall or fence, where all users of the RESTORA TION 5.1 will be able to see it. Whenever the spa is moved, the sign must also be moved and reposted near the spa. ADJUSTING THE FIL TER CYCLE The spa filter cycle runs automatically to clean the water in the spa.
16 The hydrotherapy spa is designed to provide you with years of enjoyment. Please follow the guidelines below to properly maintain your hydrotherapy spa. MAINTENANCE SCHEDULE DAIL Y ¥ Check the water level and refill the spa to the level shown on page 9, step 5.
17 SANITIZING THE HYDROTHERAPY SP A Please refer to your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa.
18 should also be drained if you will not be using it for long periods of time. The spa must always be drained before major repairs are made. The hydrotherapy spa should always be covered when it is empty . Direct sunlight can cause exten- sive damage.
19 WINTER USE AND CARE The hydrotherapy spa is designed for year-round use. If you decide to store the hydrotherapy spa for the winter , store it in a warm, dry location. Follow the steps below to winterize the hydrotherapy spa. 1. Drain the spa (see DRAINING THE HYDROTHERAPY SP A on pages 17 and 18).
20 1. SYMPTOM: THE SP A WILL NOT OPERA TE a. Check to see if the GFCI breaker is tripped, or was not turned on. Reset the GFCI breaker . 2. SYMPTOM: THE CIRCUIT BREAKER OR THE GFCI TRIPS WHILE THE SP A IS OPERA TING a. Reset the circuit breaker or the GFCI.
21 ment for excess water , and watch the pump unit while it is operating to see if water drips from any of the plumbing. If you can identify the location of the leak inside the spa jet unit, tight- en the clamp or replace the damaged seal. 10. SYMPTOM: THE SP A CONTINUES T O RUN AFTER IT HAS BEEN SHUT OFF a.
22 P ART LISTÑModel No. 831.210050 R0498A Note: Ò#Ó indicates a non-illustrated part. Specifications are subject to change without notice. Key No. Qty .
1 2 2 3 4 5 6 9 10 12 13 14 15 16 17 18 32 31 29 30 25 26 11 8 19 19 8 8 7 28 21 27 33 3 23 23 22 20 25 34 37 36 35 24 19 EXPLODED DRA WINGÑModel No. 831.
Part No. 142096 G03489BC R0498A Printed in USA © 1998 Sears, Roebuck and Co. Model No. 831.210050 QUESTIONS? As a manufacturer , we are commit- ted to providing complete customer satisfaction. If you have questions, or find that there are missing or damaged parts, we will guarantee complete satisfaction through direct assistance from our factory .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté ProForm 831.21005 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du ProForm 831.21005 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation ProForm 831.21005, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le ProForm 831.21005 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le ProForm 831.21005, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du ProForm 831.21005.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le ProForm 831.21005. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei ProForm 831.21005 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.