Manuel d'utilisation / d'entretien du produit ML100HPA du fabricant Procom
Aller à la page of 23
INFRARED VENT -FREE PROP ANE/LP GAS SP ACE H E AT E R ML060HP A ML100HP A ML100TP A TOLL-FREE NUMBER: 1-877-886-5989 W ARNING: Improper installation, adjustment, alteration, service or mainte- nance can cause injury or property damage. Refer to this manual for correct installation and operational procedures.
2 IMPORT ANT SAFETY INFORMA TION Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible f or use with other gases.
3 PRODUCT IDENTIFICA TION SAFETY DEVICE A standard requirement for all vent-free room heaters. T his heater has a pilot with an Oxygen Depletion Sensor(ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater is equipped with a piezo ignitor.
4 FRESH AIR FOR COMBUSTION AND VENTILA TION PROVIDING ADEQUA TE VENTILA TION The following are excerpts from National Fuel Gas Code. NFP A 54/ANS Z223.1, Section 5.3. Air for Combustion and V entilation. All spaces in homes fall into one of the three following ventilation classifications: 1.
5 W ARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces. AIR FOR COMBUSTION AND VENTILA TION Continued VENTILA TION AIR V entilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
6 VENTILA TION AIR V entilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: Y ou must provide two permanent openings: one within 12 " of the ceiling and one within 12 " of the floor. Connect these items directly to the outdoors or spaces open to the outdoors.
7 INST ALLA TION Figure 4 -Mounting clearances As V iewed From Front of Heater W ARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall.
8 INST ALLA TION Figure 10 - Mounting Heater Onto Mounting Bracket Figure 8 - Folding Anchor Figure 9 - Popping Open Anchor Wing For Thin Walls Attaching Mounting Bracket T o W all Note: W all anchors, mounting screws, and spacers are in hardware package.
9 INST ALLA TION CONNECTING TO GAS SUPPL Y W ARNING: A qualified service person must connect heater to gas supply. Follow all local codes. W ARNING: This appliance requires a 3/8 " NPT (National Pipe Thread) inlet connection to the pressure regulator.
10 Figure 14 -Equipment Shutoff Valve INST ALLA TION CHECKING GAS CONNECTIONS W ARNING: T est all gas piping and connections for leaks after installing or servicing. Cor- rect all leaks at once. W ARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
11 Figure 17 - Control Knob In The OFF Position Figure 18 - Pilot OPERA TING YOUR HEA TER Manual Control Models: ML060HP A,ML100HP A LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on the side of heater. 2. Check that gas supply to heater is on.
12 OPERA TING YOUR HEA TER THERMOST A T MODEL ML100TP A FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
13 INSPECTING BURNER Figure 24 - Correct Pilot Flame Pattern Figure 25 - Incorrect Pilot Flame Pattern Figure 27 - Incorrect Burner Flame Pattern Figure 26 - Correct Burner Flame Pattern ODS/PILOT AND BURNER Use a vacuum cleaner, pres - surized air, or a small, sof t bristled brush to clean.
14 TROUBLESHOOTING Note : All troubleshooting items are listed in order of operation. W ARNING: Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
15 TROUBLESHOOTING Continued OBSERVED PROBLEM Burner(s)does not light after ODS/pilot is lit. Delayed ignition of burner(s). Burner backfiring during combustion. Burner plaque(s) does not glow. Slight smoke or odor during initial operation. Heater produces a clicking/ticking noise just after burner is lit or shut off.
16 TROUBLESHOOTING Continued W ARNING: If you smell gas Shut off gas supply . Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone.
17 SPECIFICA TIONS Btu(available) Gas T ype Ignition Pressure Regulator setting Inlet Gas Pressure* (inches of water) Maximum Minimum Dimensions, Inches (HxWxD) Heater Carton Weight (pounds) Heater Shipping ML060HP A 6,000 propane/LP Only Piezo 10 " W.
18 ILLUSTRA TED P ARTS BREAKDOWN ML060HP A.
19 P ARTS LIST ML060HP A This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual.
20 ILLUSTRA TED P ARTS BREAKDOWN ML100HP A.
21 P ARTS LIST ML100HP A This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual.
22 ILLUSTRA TED P ARTS BREAKDOWN ML100TP A.
23 P ART LIST ML100TP A KEY NO. 1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PA R T NUMBER MB10007 MB09003 ML006-01 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026-02 ML069-02 845-4.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Procom ML100HPA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Procom ML100HPA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Procom ML100HPA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Procom ML100HPA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Procom ML100HPA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Procom ML100HPA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Procom ML100HPA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Procom ML100HPA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.