Manuel d'utilisation / d'entretien du produit PI 1010A du fabricant Princess
Aller à la page of 33
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 1 Not inten ded for mob il e ho me ins tall a tion. The Princess Insert By Blaz e King Model PI 1010A Ins ert Solid Fuel H eate r Residen.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 2 A pproval Labe l PRINCES S INSERT LISTED S OLID FUE L BURN IN G FIREP LA CE INSER T MODE L : PI/1010 A T este d to: R e port No. 142-S-0 5-2 UL 1482 / ULC S628 CER T IFIED IN BO T H UNI TED STA T ES A ND CA N ADA EPA Ce rt .
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 3 Dear Custo m e r: Than k you for purchasing the Pr i ncess w ood burning in s ert (hereafter referred to as "stove"). This owner's m anual explains the steps requi red to sa fely assem ble , install, operate, and m a int ain your new stove.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 4 Safet y Notice IF THIS BLA Z E KING STOV E IS N OT PROPERLY INS T ALLED, A HOUSE FIRE MA Y RESU LT.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 5 KEEP THI S MA NUAL FOR FU T U RE REFERENCE. Section _______________ _________ ________ ________ ________ ________ ________ ________ _________ ____ P age AP PROV AL LA BEL ...............
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 6 T able Of Content s As se mbly - Ge ne ral ...............................................................................................................................................
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 7 W arrant y BLAZE KIN G LI MITED WO ODST O VE W AR RAN TY - Pri nc ess Insert Blaze Kin g's war ranty policy only ap plies to units.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 8 Definitions BUILDIN G CODES A ND PERM ITS Mos t areas require a per mi t fro m the c ity or coun ty Building Inspe ctor, Fire Marsh al or Author i ty Having Juris dic- tion. Check l ocal bu ilding codes bef ore beg i nning i ns tallation.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 9 Definitions COMBUS T ION A I R INTAK E Loca ted on the f ront ri gh t of t he sto v e. Combus t ion air i s draw n into t his ope ning, through the t her m ostat and into the firebo x. In tigh t conte mporary ho m es, us ing outs ide combustion a i r may be des irable.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 10 Definitions FLUE The gene ral term f or a pas sa ge through wh ich f lue ga s es (smoke) pass f ro m the combus t ion cha mber t o the outs ide air. FUEL T H IS ST OVE IS FOR US E WI TH SOL ID WO OD FUE L ONLY.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 11 Safet y S A FET Y N OTICE IF T H IS STOV E IS N O T PROPERL Y I N STALLED , A HOUSE FIRE MAY RESU LT.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 12 Safet y CHI LDREN Do not al low children to p lay nea r t he sto v e or w i th the contro ls. Severe burns m ay be inflicted by touching th e doo r or door glass , the f ront, sides or top of the sto v e.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 13 FU EL THIS W OOD STOVE I S FOR USE W ITH SOLID W O OD FUEL ONLY. NEVER USE GASOLINE, GAS O LIN E- TYPE LAN TERN F UEL, KER OSENE , CHARC OAL LIGHTER FLUID OR SIMILAR LIQUIDS TO STAR T O R 'FRESHEN UP' A FIRE IN T HI S HEA TER.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 14 Specifications Specification PI 1010 A Min imum he a t o utpu t 6,2 00 Btu/hr Max imu m he at o utp ut 38 ,50 0 Btu/h r Overall e fficiency, w eighted average Me thod , 81 1/2% W ood capacity (appro xim ate) Whi te oa k 60 l bs .
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 15 WA R NING IMPROPER A SSEMBLY AN D/OR INSTAL LATION OF YOUR BLAZE KING WOODS TO VE OR FA ILURE T O OPERA TE IT ACC ORDING TO THE GUIDELINE S DE T AILED IN THESE INSTRUC TI ONS, W I LL VOID THE STOVE WA RR A NTY, CA N CA USE A HOUSE OR C HIMNEY FIRE, AN D MA Y ENDA NGER YOUR FAMILY.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 16 Prep a ration And Assembl y Min imum Clearances T o Co mbustible s (Measure d from In sert/Stove Sides and Top) CO M B U S TIBL E 22 &.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 17 Princess PI1010A INSERT STOVE INSTAL L A TION P ROCEDU RE A FT ER YOU REA D A ND FULLY UNDER STAN D T HE MATERIA L IN T HIS MAN UA L , YO U AR E REA DY T O PROCEED W IT H THE I NS TALLA TI ON O F YOUR S TOVE.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 18 Assembl y I nstruc tions f or Princes s PI101 0A I nsert There will be local bui lding and f ire codes w hich could affect t his i ns tallat ion.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 19 3) Ex ac t place m ent of the inse rt is de ter mined by the o v erall s hap e of your fireplace o pen ing and s urro und etc. First dete rmine w hether you w i ll need leve ling bo lts ins talled or othe r de vices to ens ure a pro per le vel ins tal- lation o f the unit.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 20 8) Slide the co mpleted un it into its fina l location. 9) Place the Con v ection de ck on the top o f the firebo x and fasten to the shro ud top us i ng the 2 scre ws pro vided (s ee F ig.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 21 CHIMNEYS: FAC T ORY-BU ILT FIRE PL A CE In Canada a n d i n the U. S.A.: If the ins ert is ins talled into a factory bu i lt fire plac.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 22 Operation Your sto v e’s perf ormance (including i ts efficiency, po l lutan t emiss i on l evel and se r vi ce lifet im e) dep end s l argel y on how i t is operated. You, then, are the m ost im porta nt f actor affect ing performance.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 23 Operation YOUR FIRS T FIRE (continued) There are four co ntrol features to you r new Bl aze King t hat are instru m ental in ge tting you r firs t fire started . 1) The Thermos tat l ocated on the right front corner of the sto v e.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 24 A couple of tips: Always hav e your ne xt intended l oad o f woo d ready whe n you open the Front Loading door.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 25 Main tenance A SH REMOVA L Ash es m ay be re moved a t any time, but m us t be remo v ed whe n they appro ach t he level of the door openin g. DO NOT re m o ve all as hes f rom t he sto v e as a w oo d fire burn s best w hen m ade on a bed o f ashe s .
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 26 Main tenance GASK ET INSPEC TI ON Insp ect t he gas ket f or phys ical deterioration , missing sections or ob v ious l eaka ge.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 27 Main tenance CA T ALYTIC COMBUS TO R , REPLA CEMEN T The catalytic ther mometer on top o f the s to ve sho uld read i n the active zon e after t he sto v e has been i n operation f or se v era l hours .
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 28 Main tenance FAN A SSEMBLY Routine l ubr i cation of t he f an motor i s not required . Periodic c leaning of the f an ass em bly ( including fan blade s ) w ith a soft brus h and v acuum clean er w ill ensu re longer li f e and ma xim um e ff iciency for the f an as s embly.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 29 T roubleshooting Your Bl aze King i s des i gned to allow a wide selection of heat outpu t l e v els . If you begin t o l os e control of the amount o f heat the sto v e is emitting, deter mi ne the cau se ea rly so that ma jor prob l ems m ay be a voided.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 30 T roubleshooting PROBLEM. Too much heat. CA USE SOLU TI ON By-Pas s door left open. C lose the by-pas s door.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 31 T roubleshooting W ood t oo gree n or w et. Use seas one d wood. Combus tor plugge d or coated . Clean co mbustor, s ee pa ge 26 . Combus tor not f unc tioning. Check and test co m busto r If neede d rep lace co m bus tor.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 32 St a ndard And Replacement Part s STAN DAR D & REPLA CEMENTS PA RTS Par t Nam e Part # Combus tor as s embly, Z4400 G Ther mometer.
DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 33 Notes:.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Princess PI 1010A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Princess PI 1010A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Princess PI 1010A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Princess PI 1010A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Princess PI 1010A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Princess PI 1010A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Princess PI 1010A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Princess PI 1010A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.