HIL T 9000 Handheld Inductive Loop T ester User Manual July 2003 R=12.3 Ω Q=12.1 L=89.2µH 50KHz ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2874 • Fax (740) 594-2875 sales@atsi-tester .
1 HILT 9000 - Inductive Loop Tester T able of Contents Receiving Y our Shipment ......................................................... 2 Packaging ..... ........................................................................... 2 Description .....
2 www.atsi-tester .com W a r nings These safety war ning are provided to ensure the safety of personnel and proper operation of the tester . • The tester must not be operated beyond its specified operating range. • Safety is the responsibility of the operator .
3 HILT 9000 - Inductive Loop Tester General Description The HILT -9000 is designed to measure characteristics of an inductive loop at dif ferent frequencies; measure working parameters of the loop system; as well as simulate the detector by measuring the change of inductance.
4 www.atsi-tester .com Overview of HIL T 9000 Contr ols 1. LOOP: Measures R DC , L, and Q . If Q >15, use Q push- button to obtain actual value. 2. Q : Measures high Q values (when Q is >15). 3. Used in SET FREQ mode to increase frequency by 1KHz.
5 HILT 9000 - Inductive Loop Tester Function Controls Power Press the POWER push-button to tur n the tester on and off. The tester per for ms an initial self-test to verify that the inter nal circuit is working. After the self-test is complete, the tester shows the current battery level and the message: Ready: Select Function .
6 www.atsi-tester .com The LOOP test can measure a maxi- mum Q of 15. If Q is greater than 15 the tester displays Q >15 . To measur e the actual value, press the Q button on the keypad to run a separate Q test. The default frequency at which the LOOP and Q tests run is 50 KHz.
7 HILT 9000 - Inductive Loop Tester , , Set Frequency When the tester is powered, the test frequency is automatically set to 50 KHz. The frequency can be changed to any value between 20 KHz and 80 KHz with 1 KHz resolution. T o set a dif ferent fr equency press the SET FREQ push-button to view the fre- quency adjustment display as show in Figure 5.
8 www.atsi-tester .com If there is bad connection, the tester displays a message as shown in Figure 7. Make sure that the test leads are properly connected. If the leads are connected to the loop and the message is still present, it means that Q of the loop is too low to generate the oscilla- tion or the inductance is out of range.
9 HILT 9000 - Inductive Loop Tester Function Controls Summary BUTTON DESC RIPTIO N COMMENTS LOOP Used to measure L, Q, and R DC of the loop. Q is measured up to 15.
10 www.atsi-tester .com Overview of T raf fic Loop Detection Systems The inductive loop represents the most commonly used method to detect vehicles. The inductive loop is simply a coil of wires embedd.
11 HILT 9000 - Inductive Loop Tester To guarantee a reliable oscillation in the loop system the quality factor ( Q ) of the loop with the lead-in wires should be above some value, deter mined by the amplifiers inside the detector .
12 www.atsi-tester .com Commonly Asked Questions Q . Why do I have to disconnect the detector from the loop before running a Loop , Q , or ∆ ∆ ∆ ∆ ∆ L test? A. During Loop, Q , and ∆ L test, the tester is applying its own signal to the loop.
13 HILT 9000 - Inductive Loop Tester Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be retur ned to our factory at one-year intervals for calibration service. In addition to calibration of the test parameters, this service includes replacement of batteries and fir mware updates.
14 www.atsi-tester .com T echnical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your tester , please call, fax, or e-mail our technical support staf f: ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2984 (740) 594-2875 - Fax service@atsi-tester .
15 HILT 9000 - Inductive Loop Tester -- This page left blank --.
16 www.atsi-tester .com Limited W arranty The HIL T 9000 (“Product”), distributed by Athens Technical Specialists, Inc. (ATSI), is warranted to the original purchaser (“Purchaser”) to be free of defects in materials and workmanship for a period of one year from the purchase date stated on the invoice.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté ATS HILT 9000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du ATS HILT 9000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation ATS HILT 9000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le ATS HILT 9000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le ATS HILT 9000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du ATS HILT 9000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le ATS HILT 9000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei ATS HILT 9000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.