Manuel d'utilisation / d'entretien du produit L80-029 du fabricant Pitco Frialator
Aller à la page of 24
L80-029 Rev 5 10/07 IMPORTANT FOR FUTURE REF ERENCE Please complete this information and retain these instructions for the life of the equipmen t: Model #: ___________ ___________ ____ Serial #: _____.
L80-029 Rev 5 10/07 WARNING Drain the tank and ensure that appliance has cooled to room temperature before performing this upgrade. DO NOT work on a hot appliance or an appliance containing hot cooking medium; serious personal injury may occur.
1 L80-029 Rev 5 10/0 7 Theory of Operation : A natural gas burning applian ce requires roughly 10 cubic feet of air to properly combust a singl e cubic foot of gas. Minute airborne particles ent rained during this process pass t hrough the combustion sy stem and are incinerated.
L80-029 Rev 5 10/07 2 Follow this procedure for Inst allation of Self Cleaning burners and SCBS arm: a. Disconnect the control harne ss from the main gas valve and tuck it out the way to avoid damaging the harness during this procedure.
3 L80-029 Rev 5 10/07 e. Using a 1 1/16” wrench and a 7/8” wrench, loosen the brass fitting on the top of t he gas valve and disconnect the gas valve from the manifold inlet. This will allow you to drop the ga s valve down and keep it out of the way during burner replacement.
L80-029 Rev 5 10/07 4 i. Captu re the remaining burners on the SCBS Arm in the same manner as in step h, an d secure them into the appliance, taking care not t o strip the pre-threaded holes.
5 L80-029 Re v 5 10/07 NOTE: CE approved models will h ave a pressure test fitting in this location. For CE app roved models, remove this pressure test fitting using a 7/16” (12 mm) wrench.
L80-029 Rev 5 10/07 6 e. Thread the compression nut on the corrugated tubing end of the SCBS Valve Assembly onto the orifice assembly that you inserted int o the runner tube in step c and tighten with a 1/2” ( 13 mm) wrench. f. Install the orifice retainer brac ket onto the pilot bracket and SCBS Orifice assembly .
7 L80-029 Rev 5 10/ 07 b. Disconnect the wiring harne ss from the relay board mounted behind the front panel and remove the relay board and insulation pape r. Be sure to retain the screws. The existing relay boa rd may or may not have a jumper plug as shown.
L80-029 Rev 5 10/07 8 e. If the appliance you are upg rading does NOT have a Solid State Control, proceed to step f in this section. If the appliance that you are up grading has a Solid State Control,.
9 L80-029 Rev 5 10/ 07 i. Conne ct the SCBS Harness to the SCBS Valve as shown. The red and violet wires m ust be connected to the vertically oriented tabs on the valve and the green (ground) wire must be connected to the bottom, horizontally oriented tab o n the valve.
L80-029 Rev 5 10/07 10 Follow this procedure to che ck proper operation of the Pi tco Self-Cleaning Burner System: WARNING Ensure that tank is filled to t he level line with oil before turning the appliance on.
11 L80-029 Rev 5 10/0 7 appliance is in operation, or ca n be detected visually by watching t he burner flame through the air collars. The sound of the burners will be inc onsistent and the flame may ap pear to ‘peel’ off of the burner fa ce. A certain amount of flame roll o ut during ignition is normal.
L80-029 Re v 5 10/07 12 PROBLEM A . Main breaker in OFF p osition. A . Turn on Circuit Breaker to appliance. B. Gas supply turned OFF. B. Turn on gas supply to appliance. C. A ppliance unplugged. C. Plug appliance pow er cord into wall ou tlet. D. Blown con trol fuse.
13 L80-029 Rev 5 10/ 07.
L80-029 Rev 5 10/07 14.
15 L80-029 Rev 5 10/ 07.
L80-029 Rev 5 10/07 16.
17 L80-029 Rev 5 10/07.
L80-029 Rev 5 10/07 18.
19 L80-029 Rev 5 10/07.
L80-029 Rev 5 10/07 20.
21 L80-029 Rev 5 10/07 Before and After: Visual Aid The below images show a typical m odel SG14 burner assembly before and after the installation of the SCBS upgrade.
MAILING ADDRESS – P. O. BOX 501, CONCORD, NH 033 02-0501 SHIPPING ADDRESS – 10 FE RRY ST., CONCORD, NH 03 301 In th e eve nt of prob lem s wit h or qu est ion s abo ut you r orde r, plea se conta .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pitco Frialator L80-029 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pitco Frialator L80-029 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pitco Frialator L80-029, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pitco Frialator L80-029 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pitco Frialator L80-029, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pitco Frialator L80-029.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pitco Frialator L80-029. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pitco Frialator L80-029 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.