PDP-504CMX Plasma Display Panel RS-232C Commands C OMMAND P ROTOCOL M ANUAL Manual Version 1.00 November 3, 2004 Pioneer Corporation Pioneer Electronics (USA) Inc.
This manual is copyrighted with all rights reserve d. No part of this document may be repri nted, produced, translated or utilized in any form or by any means now known or her eafter invented includi .
1 RS-232C Adjustment Mode 5.5 RS-232C Adjustment Mode This display has a RS-232C terminal. It is possible to use a PC to make various adjustments and settings. 5.5.1 About the RS-232C Adjustment Mode 1) Adjustments in the RS-232C adjustment mode: • The adjustments are written to the same memory area as for the integrator mode (refer to section 5.
2 RS-232C Adjustment Mode 5.5.2 Interface 1) Connector D-sub 9 pins (male) 2) Pin layout 3) Baud Rate 9600 bps (standard) (switch-able to 1200, 2400, 4800, 19200, 38400 bps) Note The baud rate of this display should be set to match the baud rate of the PC.
3 RS-232C Adjustment Mode 5.5.3 ID Assignment After connecting to the PC, an ID is assigned. The ID is assigned from the PC. Commands: <IDC> (ID CLEAR) ........ Clears the assigned ID <IDS> (ID SET) ............. Assigns an ID IDS is only effective when an ID is not assigned.
4 5.5.4 Combination Connection When performing control and adjustment, it is convenient to connect several sets to one PC. By performing a combination connection and assigning IDs to the sets, it is possible to control and adjust several sets at the same time or separately.
5 Under the connection conditions shown below, operation using a combination cable is assured up to 16 sets. Conditions: 1 Length of RS-232C cable connecting PC to PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S: .
6 RS-232C Adjustment Mode 5.5.5 List of RS-232C Commands How to read this Table • RS-232C adjustment validity : Indicates whether or not the RS-232C adjustment mode can be used. • Normal validity : Indicates whether or not the normal-operation mode can be used.
7 RS-232C Adjustment Mode CTR CTI: ### Displays the current CTI setting. ¶ CTRS00 CTI: OFF Sets CTI to OFF. ‡ CTRS01 CTI: ON Sets CTI to ON. ‡ [D] DIN Turns OFF the OSD display. ‡‡ DIY OSD: ON Turns ON the OSD display. ‡‡ DNR DNR: ###### Displays the current DNR setting.
8 RS-232C Adjustment Mode GRA GRADATION: ####### Displays the current GRADATION setting ¶ GRAS01 GRADATION: GAMMA 2.0 Sets GRADATION to ‘ GAMMA 2.0 ’ . ‡ GRAS02 GRADATION: GAMMA 1.8 Sets GRADATION to ‘ GAMMA 1.8 ’ . ‡ GRAS03 GRADATION: GAMMA 2.
9 RS-232C Adjustment Mode MIR MIRROR MODE: ### Displays the current MIRROR MODE setting. ¶ MIRS00 MIRROR MODE: OFF Turns the MIRROR MODE OFF (normal display). ‡ MIRS01 MIRROR MODE: X Sets the MIRROR MODE to left-right reversal. ‡ MIRS02 MIRROR MODE: Y Sets the MIRROR MODE to up-down reversal.
10 RS-232C Adjustment Mode SSI ######### Displays the current sub screen input function. ¶¶ SSIS01 INPUT1(SUB) Switches the sub screen to INPUT1. ‡‡ SSIS02 INPUT2(SUB) Switches the sub screen to INPUT2. ‡‡ SSIS03 INPUT3(SUB) Switches the sub screen to INPUT3.
11 RS-232C Adjustment Mode 5.5.6 GET Commands What are GET commands? • They are commands for outputting TXD such as adjustment data from the internal microcomputer of the plasma display to a PC. • Adjustment data and the like is output in ASCII code.
12 RS-232C Adjustment Mode 2) <GPI> (GET PICTURE DATA: Gets integrator/PICTURE data.) Order Data contents Size Remarks 1 CONTRAST 3 Byte # 2 BRIGHTNESS 3 Byte # 3 C. DETAIL R (RED) 3 Byte # 4 C. DETAIL Y (YELLOW) 3 Byte # 5 C. DETAIL G (GREEN) 3 Byte # 6 C.
13 RS-232C Adjustment Mode 5) <GSS> (GET STATUS SETUP: Gets menu and integrator SETUP data.) Order Data contents Size Output Remarks 1 GRADATION 1 Byte 1: GAMMA 2.0 2: GAMMA 1.8 # 3: GAMMA 2.2 4: DRE MID 5: DRE HIGH 6: DRE LOW 7: HIGH CNT. 2 BRT.
14 RS-232C Adjustment Mode 6) <GSO> (GET STATUS OPTION: Gets menu and integrator OPTION data.) Order Data contents Size Output Remarks 1 ENERGY SAVE 1 Byte 1: STANDARD 2: MODE 1 3: MODE 2 4: MOD.
RS-232C Adjustment Mode Check Sum This is data to which 2-Byte ASCII code is added to a data group returned by a GET command. PC side STX ID GET command ETX 02 (hex) 2 Byte 3 By te 03 (hex) Set side STX GET command Data Check Sum ETX 02 (hex) 3 Byte *Byte 2 Byte 03 (hex) A det ailed example will be given below .
PDP-504CMX RS-232C Command Protocol Manual Pioneer Electronics (USA) Inc. Industrial Solutions Business Group 2265 East 220 th Street Long Beach, California 90810 United States of America (310) 952-2000 http://www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pioneer PDP-504CMX c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pioneer PDP-504CMX - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pioneer PDP-504CMX, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pioneer PDP-504CMX va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pioneer PDP-504CMX, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pioneer PDP-504CMX.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pioneer PDP-504CMX. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pioneer PDP-504CMX ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.