1 Installation/Operator’s Manual 1 Rev: February, 02-20-2006 THIS MANUA L SUPERCEDES ALL PREVIOUS VERSIONS OF THIS MANUAL Installation To insure optimum performance and safe operations please follow the detailed information provided with each furnace.
TABLE OF CONTENTS FURNACE SPECIFICATIONS pg 2 CONTROL AND COMPONENT FUNCTIONS pg 3 GENERAL INSTRUCTIONS pg 4-5 CLEARANCE TO COMBUSTIBLES (diagram) pg 6 CHIMNEY AND VENTING pg 7 VERTICAL CHIMNEYS pg 8 .
FURNACE SPECIFICATIONS HEIGHT--------------------------------------------------- 45 ¼ WIDTH---------------------------------------------------- 24 ¼ DEPTH--------------------------------------------.
CONTROL AND COMPONENT FUNCTIONS AUGER The auger transfers the pellet fuel from the hopper end of the burner tube down and into the fire pot. AUGER MOTOR The auger drive motor turns the auger. BURNER TUBE The burner tube contains two passageways, one for the auger tube and the other for combustion air.
GENERAL INSTRUCTIONS 1. Installation is allowed only by a licensed, bonded heating contractor. 2. Install this furnace in accordance with local mechanical codes and regulations. 3. Consult manual “J” of the air conditioning contractors Association (ACCA) or air 230 to estimate heating requirements.
19. Doors and heat exchanger surfaces of the furnace are hot during operation. DO NOT touch with bare hands, or allow children to play near the furnace unattended. 20. Do not allow anyone to operate the furnace that is not familiar with its operation.
CLEARANCE TO COMBUSTIBLES 6.
CHIMNEY AND VENTING Chimney required for the GBU070 is 4” Class “L” (also known as PL vent). A starting collar must be used to attach the venting system to the furnace. When connecting into a Class “A” or masonry chimney an approved 4” liner MUST be used to prevent back drafting of the chimney.
VERTICAL CHIMNEY’S The chimney that this unit is connected to (Cla ss “L”, all fuel or masonry) should extend above the roofline of adjacent buildings to prevent downdraft situations. 1. Class “L” connectors shall be installed without any downward pitch from the appliances and without any dips or sags.
DUCTING PRIMARY FURNACE To install the GBU070 as a “Primary Furnace” first locate the furnace as near the chimney and as centralized with respect to heat distribution as practical. Follow all clearance to combustible requirements. Connect the ductwork to the furnace.
ELECTRICAL REQUIREMENTS 1. Make sure that the power source conforms to the requirements of the furnace. Disconnect the power source before performing any maintenance or electrical work. 2. Connect the electrical power according to the appropriate wiring diagram on the following page.
TURNING OFF THE UNIT Turn the power switch to draft fan. Fuel w ill stop feeding but the draft fan will remain running. Let run until fire burns out completely. Set power switch to off. NOTE: Approximately 10 – 12 minutes should be enou gh time for fire to burn out.
BURNING CORN IN THE GBU070 NOTE : If your 070 was purchased as a corn unit the corn pot should already be installed. The corn pot utilizes a lift out cast iron inner liner that removes for easy cleaning. A rod will also be provided to lift the pot out of the furnace.
11. Let the pot cool completely to the touch and place into a bucket of water to dissolve the clinker. DO NOT PLACE HOT POT IN WATER; FAN LIMIT CONTROL NOTE! IN CO RR ECTLY INSTALLED CONTRO L C A N CAUSE ELECTRIC SHOC K HAZA RD OR DA MAGE TO LOW VOLTAGE CONTROLS.
START UP INSTRUCTIONS – PELLET Now that your furnace has been properly installed, it’s time to fire it up! 1. Plug in the furnace. NOTE: Make sure you plug into a properly grounded, surge- protected outlet that has proper polarity so as not to damage the circuitry of the control board.
START UP INSTRUCTIONS – CORN NOTE: Pellets are required to start your initial fire. 14. Plug in the furnace. NOTE: Make sure you plug into a properly grounded, surge- protected outlet that has proper polarity so as not to damage the circuitry of the control board.
PRIMARY CONTROL OII 350S SEQUENCE OF OPERATION The Traeger OII 350S primary control is a high-tech, state of the art computer. The control performs the function of piloting the system when the thermostat does not call for heat. It conserves fuel consum p tion.
TROUBLE SHOOTING GUIDE Tools Essential for Trouble Shooting 1. Furnace Installation and Operation manual 2. Circuit Tester / Volt Meter 3. Molex pin Extractor 4. Volt Meter ATTENTION: Before attempting any trouble shooting: 1. Check your outlet (for 070) or your wiring to breaker box (130 & 150) to insure proper polarity and grounding.
STEP 3# CONFIRM DRAFT FAN OPERATION Be sure the main power switch is in the “Draft Fan” position. This will cause the draft fan to operate at full power (110v).
INSTALLATION/ADJUSTMENT RELATED PROBLEMS PROBLEM: Incomplete combustion, unburned fuel. SOLUTION : 1. Adjust air shutter to a more open position. 2. Make sure of correct chimney, is chimney drafting? Is the chimney direct vented? Is it a tight basement? Outside air may be needed.
OPERATOR RELATED PROBLEMS cont’d PROBLEM: Furnace will not feed fuel. SOLUTION: Check for blockage in metering cup. Is there fuel in the hopper? FUEL RELATED PROBLEMS Symptoms of Poor Fuel: 1. Unburned pellets 2. Fire pot overflows as a result of high moisture content.
#10. The blower cycles on and off too much. CHECK CAUSES: 9, 12, 22 or 59. #11. Furnace burns without regard to thermostat, overheats. CHECK CAUSES: 4, 8, 13, 14, 18, 30, 31, 33 or 50 #12. Furnace doesn't make as much heat as it used to. CHECK CAUSES: 5, 32, 37, 40, 53, 56, 57 or 59.
3. An impurity in the pellets has hung up the auger. Remedy: The cup is turning but the auger is not. Loosen the coupling on the auger and try to turn free. Do not force it. You may have to remove the auger to clear. 4. Fines and dust are accumulating in the burner compartment area.
16. Improper stove ground. Remedy: Check the ground. Check the outlet. Just because there is a three-prong outlet receptacle does not mean that there is a ground wire hooked up to it, and then where does that ground wire go to? This appliance must be properly grounded.
28. Too much chimney draft. Remedy: Check draw with a draft gauge. Maxi mum draft .08 inches. If draw exceeds .08 reduce chimney outlet to accomplish. 29. Too little draft. Remedy: Check draw of chimney with a draft gauge. Minimum draft .04 inches. May have to add more chimney.
43. Undersized or overloaded service wiring. Remedy: Call your electrical contractor. 44. Power surge. Remedy: Call your electrical contractor. 45. Power short in unit. Remedy: Locate short circuit and correct. 46. Pellets in hopper are giving off an odor.
59. Aluminum air filter is dirty. Remedy: Remove from furnace and wash. 60. Inadequate return air. Too small, re stricted, or is pulling unconditioned air.
PARTS LIST 1. Hopper connector flange F000221P 8. Cup motor F000101P 2. Pillow block ball bearing F000505P 9. Manual reset F000105P 3. Cutting blades (2) ea. F070513P-2 10. Auger motor F000102P 4. Fuel metering cup F070512P 11. Draft inducer F000103A 5.
WARRANTY NON TRANSFERABLE MODEL: _ GBU070 ___________ SERIAL NUMBER: ____________________ DATE PURCHASED: __________________ FROM: __________________________ Complete Unit Warranty The manufacturer pr.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pinnacle Speakers GBU070 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pinnacle Speakers GBU070 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pinnacle Speakers GBU070, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pinnacle Speakers GBU070 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pinnacle Speakers GBU070, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pinnacle Speakers GBU070.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pinnacle Speakers GBU070. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pinnacle Speakers GBU070 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.