Manuel d'utilisation / d'entretien du produit 818T0101 du fabricant Pella
Aller à la page of 16
P art Number: 818T0101 © 2011 P ella Corpor ation Sill Flashing T ape #2 Sill Flashing T ape #1 Sill Support To p Flashing T ape Side Flashing T ape Wea ther Resistive Barrier F raming Sheathing Installation Instructions for T ypical Wood F rame C onstruction.
Y OU WILL NEED T O SUPPL Y : T OOLS REQUIRED: Ř Composite/impervious shims/spacers (12 to 20) Ř #8 x 3" corrosion r esistant woodscrews Ř 16d galvanized finish nails or exterior grad.
D. Cut the weather resistive barrier , if applicable (1D). 4th cut: Make a 6" cut up fr om each top corner at a 45° angle to allow the weather barrier to be lapped over the fin at the head of the door . 1st cut 2nd cut 3rd cut W ater Resistive Barrier 1D 1D E.
2 PREP ARE THE DOOR FOR INST ALLA TION TWO OR MORE PEOPLE WILL BE REQUIRED T O HANDLE THE P ANEL AND FRAME SAFEL Y . A. Remove plastic wr ap and cardboar d packaging fr om door . DO NOT remove plastic shipping spacers. T he shipping spacers will help keep the door square during installation.
81-1/2" 81-1/2" 3" 3" 21" 9-1/4" 9-1/4" 3" 3" 21" 21" 3" 3" 21" 6-3/4" 6-3/4" 3" 3" 21" 21" 97-1/2" 21" 97-1/2" 6" 6" 6" 6" 6" 6" = Screw or clip location other than at hinge or strike.
A. If unit is equipped with a screw type pre-hanging plug for tr ansporting, remove the scr ew portion fr om the exterior of the jamb before setting the door . Note: If a brickmould/exterior trim is being added to the door, install and seal it to the frame a t this time.
E. Plumb and Square Door . Shim unit in place by driving in shims from the interior . Shim behind each hinge, at each screw or clip loca tion, and behind the dead bolt lockstrike.
3 SETTING AND F ASTENING THE DOOR (CONTINUED) CORRECT INCORRECT 2G 3F F. Car efully open the door and remove all shipping spacers. Remove pr e-hang plug from the bor e hole. Car efully open and close the door . Check for even contact between the door panel and weatherstrip on both jambs and across the head.
3 SETTING AND F ASTENING THE DOOR (CONTINUED) N. Check for suf ficient weatherstrip contact between the bottom weatherstrip and the thr eshold. Close the door on a dollar bill or sheet of paper located above an adjustment screw; light friction should be felt when pulling the paper out indicating a good seal is being made.
O. If needed, the height of the threshold can be adjusted to achieve appropria te contact with the door sweep. Remove screw cover caps as necessary and use a #3 Phillips screwdriver to turn the adjustment screws clockwise to lower the threshold or counter -clockwise to raise the threshold.
E. Install top flashing tape. Cut one piece of flashing tape 2" wider than the width of the top brickmould. Apply the top flashing tape so it extends 1" beyond the end of the top brickmould. P osition the tape so it covers the vertical leg of the aluminum flashing and laps onto the sheathing above the door .
5 INTERIOR SEAL Caution: Ensur e use of low pressure polyurethane window and door installation foams and strictly follow the foam manufacturer’ s recommendations for applica tion. Use of high pressure foams or improper application of the foam may cause the door to bow and hinder operation.
Note: When applying siding, brick veneer or other exterior finish materials, leave adequate space between the door fr ame and the material for sealant.
A. Insert back er rod into the space ar ound the door so there is appr oximately 1/2" clearance between the back er rod and the face of the door frame. Note: Backer r od adds shape and depth for the sealant line. B. Apply a bead of high quality exterior grade sealant to the entir e perimeter of the door.
FINISHING INSTRUC TIONS P aint or finish immediately after installation. Note: DO NO T paint, stain or finish weather strip or vinyl parts! If paint, stain or finish gets on the weather stripping, wipe it off immediately with a damp cloth. T o maintain proper product performance, do not remove wea ther strip, foam corner seal wedges or gaskets.
IMPORT ANT NO TICE Because all construction must anticipate some water infiltr ation, it is important that the wall system be designed and constructed to properly manage moistur e.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pella 818T0101 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pella 818T0101 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pella 818T0101, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pella 818T0101 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pella 818T0101, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pella 818T0101.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pella 818T0101. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pella 818T0101 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.