SS20, SS22, SS2000, SS2002 Series Discr eet Sur veillance Enclosures Installation/ Operation Manual C429M-B (2/98) Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.
2 Pelco Manual C429M-B (2/98) REVISION HISTOR Y Manual # Date Comments C429M-A 10/94 Wire colors revised on figures 2-4, 6 and 7. (Pin 8 - Figure 2; Pins 8 & 23 - Figures 3 and 4; Pins 8, 11, 12, 13 - Figures 6 and 7.) C429M-B 7/96 Revised to include new models SS22 and SS2002-SL.
Pelco Manual C429M-B (2/98) 3 1.0 GENERAL CAUTION: This device is designed to operate at 24 volts AC power . Input volt- ages must not exceed 28 volts or drop below 22 volts, or else damage the the motors will occur . Should you need technical assis- tance, please call (800) 289- 9100.
4 Pelco Manual C429M-B (2/98) 2.0 DESCRIPTION Pelco’ s SS20/SS22/SS2000/SS2002 Series domes are full-sphere, discreet sur- veillance enclosures designed to be suspended from ceilings and to compliment the interior design of businesses, hotels, and offices.
Pelco Manual C429M-B (2/98) 5 3.0 INST ALLA TION Save the shipping carton and plastic packing in case the unit has to be returned for credit or repair . 3.1 CONDUCTOR AND CABLE REQUIREMENTS A minimum of 1 1 conductors plus coax is required, which includes common re- quirements for motorized zoom lens and camera AC power .
6 Pelco Manual C429M-B (2/98) Figure 2 . SS2000/SS2000-SL/SS2002-SL W iring Diagram.
Pelco Manual C429M-B (2/98) 7 Figure 3 . SS2000-PP W iring Diagram.
8 Pelco Manual C429M-B (2/98) Figure 4 . SS2000SL-PP Wiring Diagram.
Pelco Manual C429M-B (2/98) 9 Figure 5 . Connector Assembly 3.2 CONNECTOR ASSEMBL Y T o install and test the SS2000/SS2002 Series dome you will need to assemble the connector parts provided. Fabricate the interconnecting cable as outlined below (see Figure 5): 1.
10 Pelco Manual C429M-B (2/98) 8 4 3 1 14 9 20 15 25 21 28 26 FRONT VIEW 28-PIN CONNECTOR CABLE CLAMP' CON206070-1 CABLE, 12 COND. @ 6' WIR201912 CABLE, 9 COND. @ 6' WIR220709 COAX @ 6' WIRRG174/U CONCPM88-174 28-POS RECEPTACLE CON205839-3 CRIMP SOCKET CON1-66504-0 Figure 6 .
Pelco Manual C429M-B (2/98) 11 3.3 MOUNTING The SS2000/SS2002 enclosure is designed to be suspended from a suitable length of 1-1/2" pipe threaded at both ends. This pipe can be interfaced to either a Pelco MRW A wall adapter , MRCA ceiling adapter, or coupled to a longer length of pipe.
12 Pelco Manual C429M-B (2/98) 3.4 DOME INST ALLA TION T o install your dome system, perform the following steps (refer to Figure 9): 1. Select the appropriate pipe length and mounting method. If the MRCA or MR WA mount is used, tighten the pipe to approximately 30 ft lb, then tighten the 8-32 screw in the pipe nut to lock the pipe threads.
Pelco Manual C429M-B (2/98) 13 4.0 EXPLODED ASSEMBL Y DIAGRAM T able A. SS2000/SS2002 Exploded Assembly Diagram Item Qty Description Part Number 1 1 Dome, upper SS200010000 2 1 Dome, lower, Black (Opa.
14 Pelco Manual C429M-B (2/98) Figure 9 . SS2000/SS2002 Exploded Assembly Diagram.
Pelco Manual C429M-B (2/98) 15 5.0 ADJUSTMENTS T o adjust the pan/tilt limits, perform the following steps. Refer to Figure 10 for limit stop locations. Factory pan limits are set to 0-355 ° and tilt limits are set to 0-90 ° (horizontal to vertical).
16 Pelco Manual C429M-B (2/98) 6.0 MAINTENANCE Clean the acrylic lower dome as necessary to maintain a clear picture. Be careful not to scratch the surfaces of the dome. Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning cloth and cleaning agent that is safe for acrylic plastic.
Pelco Manual C429M-B (2/98) 17 7.0 SPECIFICA TIONS ELECTRICAL Input Voltage: 24 VAC required for pan/tilt Running Current Pan: 0.31 amp (7.44 vA) Tilt: 0.
18 Pelco Manual C429M-B (2/98) GENERAL Maximum Camera/ Lens Length: 12.5 inches (31.75 cm) Ambient Temperature Range: 35 ° F to 120 ° F (1.6 ° C to 48.
Pelco Manual C429M-B (2/98) 19 NOTES.
20 Pelco Manual C429M-B (2/98) 8.0 WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Excep- tions to this warranty are as noted below: • Three years on Genex™ Series multiplexers.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pelco SS2000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pelco SS2000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pelco SS2000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pelco SS2000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pelco SS2000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pelco SS2000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pelco SS2000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pelco SS2000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.