Manuel d'utilisation / d'entretien du produit MPT9500TDX du fabricant Pelco
Aller à la page of 20
MPT9500 Series T ransmitter/ Contr oller Installation/ Operation Manual C535M-B (8/98) Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.
2 Pelco Manual C535M-B (8/98) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 5 1.1 IMPORT ANT SAFEGUARDS AND WARNINGS ............................... 5 2.0 DESCRIPTION .
Pelco Manual C535M-B (8/98) 3 REVISION HISTOR Y Manual # Date Comments C535M 12/93 Original version. C535M-A 1/95 Updated manual to include preset tour programming and other software updates. Sections 5.0 through 5.3.9 are totally new material as per ECO #95-006.
4 Pelco Manual C535M-B (8/98) (This page intentionally left blank.).
Pelco Manual C535M-B (8/98) 5 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed.
6 Pelco Manual C535M-B (8/98) 2.0 DESCRIPTION The MPT9500 T ransmitter/Controller provides control in V ertical Interval Signaling (standard or extended Coaxitron ® ) and RS-485 formats.
Pelco Manual C535M-B (8/98) 7 3.0 INST ALLA TION 3.1 THE VIS (COAXITRON ® ) CONTROL SYSTEM The operating distance for the V ertical Interval Signaling (VIS) system is probably the most crucial installation parameter . For a VIS control system, the maximum loss allowed across the coax is 4 dB at 1 MHz.
8 Pelco Manual C535M-B (8/98) 3.3 CONNECTING TO THE RECEIVERS The rear panel view and pin out for the 6 pin modular cable is shown in Figure 3. Refer to Figures 4 and 5 for additional system configurations. Figure 2. RS-485 Duplex Control System (PTZ Control and Alarm Reporting) Figure 3.
Pelco Manual C535M-B (8/98) 9 Figure 4. RS-485 Simplex System (PTZ Control Only) Figure 5. Combination Coaxitron ® and RS-485 (Simplex) System CX9504 CX9504 PROGRAMMING MONITOR 1 TXD (–) 2 TXD (+) 3 GND 4 GND 5 RXD (–) 6 RXD (+) RXD (–) RXD (+) KEEP PARALLEL CONNECTIONS INTO RECEIVERS VERY SHORT; NO “T” CONNECTIONS.
10 Pelco Manual C535M-B (8/98) 4.0 OPERA TION The MPT9500 operates in one of three modes: Coaxitron ® Standard (15-bit proto- col), Coaxitron ® Extended (32-bit protocol) and RS-485.
Pelco Manual C535M-B (8/98) 11 4.1 SELECTION OF ST ANDARD COAXITRON ® To select the Standard Coaxitron ® mode of operation, press the number “1” key and then press the “COAX RECV” key . The default keyboard display will read “STD CXTRN”.
12 Pelco Manual C535M-B (8/98) Enter whatever number you desire or need and press the “PRESET SET” key . The keyboard display will show: and the following screen will pop up on the monitor: giving you the programming information you need to create a preset label on the monitor .
Pelco Manual C535M-B (8/98) 13 and on the monitor the following screen will appear: NOTE: Before programming a tour for the FIRST TIME , it is recom- mended that you clear the pro- gramming area by pressing the turbo button on the joystick (see Figure 7).
14 Pelco Manual C535M-B (8/98) NOTE & W ARNING: While in the programming preset tours mode, you may delete all previously programmed tour steps by press- ing the turbo button on the joystick (see Figure 7). Make sure you re- ally want to do this before pressing the button.
Pelco Manual C535M-B (8/98) 15 ZOOM SPD ENTER ZOOM SPEED 1 - 4 and PUSH SELECT F1 TO EXIT FOCUS SPD ZOOM SPD 3 4.3.6 Programming Lens Speed This feature is only available on receivers that support programming lens speed. T o program lens speed, press the number 8 key followed by the F1 key .
16 Pelco Manual C535M-B (8/98) Blinking SET AUX TYPE RECEIVER # JOYSTICK SELECT TO SET F1 TO EXIT AUX 1 2 3 4 5 6 7 8 LA T MOM ❊ ❊ ❊ ❊ ❊ ❊ ❊ ❊ → → → → where: “LAT” means latching “MOM” means momentary and 4.3.9 Programming Auxiliary Functions This feature will operate only on receivers that support this option.
Pelco Manual C535M-B (8/98) 17 EDIT ZONE LABEL USE JOYSTICK UP DOWN CHAR SET CHAR POSITION F1 TO SEND LABEL CLEAR TO EXIT 4.3.10.2 Pattern End Point If the pattern time is less than the maximum allowed, simply end the pattern se- quence by pressing the number 2 key and then press the F1 key .
18 Pelco Manual C535M-B (8/98) YEARS ENTER YEAR and PUSH SELECT F1 TO EXIT 4.3.12 Time (MPT9500TD Only) The MPT9500 is equipped with a time clock for specific functions requiring refer- ence to time and date. 4.3.12.1 Set Time (MPT9500TD Only) To set the time, press the number 1 key followed by the F2 key .
Pelco Manual C535M-B (8/98) 19 5.0 SPECIFICA TIONS ELECTRICAL Input Voltage: (50/60 Hz) 120, 230 VAC Power Consumption: 12 watts Control Method: Coaxitron ® VIS 4-wire RS-485 Standard Baud Rates: VIS 1 MHz RS-485 2400 baud Command Error Rates: DUPLEX 0% SIMPLEX 2% Input Video Level: 0.
20 Pelco Manual C535M-B (8/98) 6.0 W ARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. © Copyright 1998, Pelco. All rights reserved.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pelco MPT9500TDX c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pelco MPT9500TDX - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pelco MPT9500TDX, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pelco MPT9500TDX va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pelco MPT9500TDX, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pelco MPT9500TDX.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pelco MPT9500TDX. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pelco MPT9500TDX ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.