® INST ALLA TION F T82041/FR82041 Unmanaged Ethernet Switch Four 10BASE-T/100BASE-TX Ports and One 100BASE-FX Fiber Port C2623M (2/07).
.
C2623M (2/0 7) 3 Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Not ices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 C2623M (2/07) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings.
C2623M (2/0 7) 5 The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
6 C2623M (2/07) Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation.
C2623M (2/0 7) 7 Product Overview DESCRIPTION The F T82041/FR82041 unmanag ed Ethernet switch provid es four 10BASE-T/100BASE-TX ports and one 100BASE-FX fiber port for the trans port of bidirectional Ethernet data.
8 C2623M (2/07) • Designed to meet NEMA TS 2 and Caltrans traff ic signal control equipment standards for ambient operating temperature, mechanical shock and vibrati on, humidity with condensation, .
C2623M (2/0 7) 9 OPTIONAL ACCESSORIES The following optional a ccessories are available: WM5001-3U Wall mount base ki t for single-width module WM5001-3UEXP Wall mount expansion kit for single-width m.
10 C2623M (2/07) REAR PANEL Figure 3 illustrates the rear pa nel of the F T82041 and FR82041 modules. Figure 3. Rear Panel of F T82041 and FR82041 Mo dules (SC Fiber Connector Shown) For additional information about r ear -panel connections, refer to Installation on page 11.
C2623M (2/0 7) 11 Installation PACKAGE CONTENTS The following it ems are supplied: 1 F T82041 or FR82041 module 1 Regulated switching power suppl y with four plug adapt ers (North American, Australian, U.K., and European configurations); 100-240 V A C, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4-40 x 0.
12 C2623M (2/07) Using the TX Mode switch for a parti cular port, y ou can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegotia.
C2623M (2/0 7) 13 NOTE: TX Mode configuration must be set when the module is powered off. If you wish to change a TX Mode switch setting after the module has been powered on, power of f the module, change the TX Mode switch setting, and then power on the module again.
14 C2623M (2/07) Mounting the F T82041/FR82041 Module Using the Wall Clip NOTE: Before mounting the F T82041/FR82041 module to a wall, ensure that there is adequate space at both ends for viewing the fr ont-panel LEDs and for making the various rear-pa nel cable connec- tions.
C2623M (2/0 7) 15 CONNECTIONS Connections to the F T82041/FR82041 module are made on the rear panel of the unit (refer to Figure 6). Figure 6. F T82041/FR82041 Module Connecti ons As illustrated in Fi.
16 C2623M (2/07) • Fiber connection NOTE: Fiber port A of the F T82041 module connects to fiber port B of the FR82041 module or of any other Pelco Ethernet sw itch that supports wavelength division multiplexing (WDM).
C2623M (2/0 7) 17 T roubleshooting LED indicators on the front and rear panels of the F T82041/FR82041 module allow you to monitor operational status: • LED indicators on the front panel allow you to monitor operating power , 100BASE-FX port status, and optic signal/l aser status.
18 C2623M (2/07) Optic Fault LED ( ) Green The optical signal is being received and laser is operating properly . — No action is required. Red The optical signal is not being received. Remote module is not powered on. Check power connections. Replace power supply if necessary .
C2623M (2/0 7) 19 T able C. T roubleshooting with Rear -Panel Indicators Indicator Color Meaning Possibl e Cause Corrective Action RJ-45 10BASE-T/100BASE-TX Port Stat us LED - Left (Link / Activity) Amber A 10BASE-T link is established. — If 10BASE-T operation is desired, no action is required.
20 C2623M (2/07) RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued) Not lit A 10BASE-T or 100BASE-TX link cannot be estab- lished. A problem may exist with the cable: • Cable is not connected to the module or to the 10BASE-T/100BASE-TX compatible device.
C2623M (2/0 7) 21 RJ-45 10BASE-T/100BASE-TX Port St atus LED - Right (Duplex/Collision) Amber Port is set to 10BASE-T full- duplex mode. — If 10BASE-T full-duplex opera- tion is desired, no action is required.
22 C2623M (2/07) RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Co llision) (Continued) Green Port is set to 100BASE-TX full- duplex mode. — If 100BASE-TX full-duplex operation is desired, no action is required.
C2623M (2/0 7) 23 RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Co llision) (Continued) Not lit Port is set to 10BASE-T half- duplex mode and no collisions are detected.* — If 10BASE-T half-duplex operation is desired, no action is required.
24 C2623M (2/07) Specifications PERFORMANCE Switch T ype Unmanaged Layer 2 Switch Method Store and forward Switch Fabric Non-head-of-line blocking Data Rate 10/100 Mbps Compliance IEEE 802.
C2623M (2/0 7) 25 OPTICAL POWER BUDGET AND MAXI MUM TRANSMISSION DIST ANCE Model Number Wavelength (T ransmit/Receive)* Optical Power Budget Maximum T ransmission Distance T ransmitter End Receiver End Fiber Port A Fiber Port B Multimode (62.5/125 μm) F T82041MSTR-1 FR82041MSTR-1 1310/850 nm 850/1310 nm 26 dB † 2 km (1.
26 C2623M (2/07) Appendix. RJ-45 Connector Pinouts Figure 7 illustrates RJ-45 MDI/MDI-X connector pinouts. Figure 7. RJ-45 MDI/MDI-X Connector Pinouts T able D summarizes RJ-45 MDI/MDI-X connector pinouts.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or work manship for a period of one year after the date of shipment.
® Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pelco FR82041 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pelco FR82041 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pelco FR82041, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pelco FR82041 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pelco FR82041, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pelco FR82041.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pelco FR82041. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pelco FR82041 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.