SB19/SB1900 Series Discr eet Surveillance Enclosures Installation/Operation Manual C467M-D (5/95) ® Pelco • 3500 W. Pontiac Way, Clovis, CA 93612-5699 • USA • www.
REVISION HISTORY Manual # Date Comments C467M 2/90 Original Version. C467M 3/90 Rev. A. “Scope” section expanded to include warnings. Updated model and options section. Figure 5 Added. C467M 11/90 Rev. B. Addendum incorporated @ Figure 19 Exploded Assy Diagram.
Pelco Manual C467M-D (5/95) 1 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
2 Pelco Manual C467M-D (5/95) 2.0 SCOPE The information contained within this manual covers the SB19/SB1900 Series of Discreet Surveillance En- closures.
Pelco Manual C467M-D (5/95) 3 Figure 1. SB1900 Series Wiring Diagram.
4 Pelco Manual C467M-D (5/95) 4.3 MOUNTING INSTRUCTIONS Determine the type of mounting desired. The enclo- sure can be mounted in a hard ceiling, completely re- place a standard 2' x 2' suspended ceiling tile using the APSB19 optional faceplate, or be inserted through a cut-out in a standard 2' x 2' suspended ceiling tile.
Pelco Manual C467M-D (5/95) 5 7. Slide the back box through the ceiling tile and mounting plate and replace the four (4) 1/4-20 bolts and tighten to secure the back box to the mounting plate. 8. Check the alignment of the back box to the ceiling tile by attaching the 12.
6 Pelco Manual C467M-D (5/95) 13. Attach the dome to the pan/tilt by aligning the two ball studs protruding through the flange of the dome with the two holes in the dome attachment brack- ets and engaging the studs. 14. Attach the safety chain on the side of the back box to the short 4-40 threaded screw in the 12.
Pelco Manual C467M-D (5/95) 7 4.3.1.2 Suspended Ceiling Tile Replacement Mounting T o mount the enclosure into a suspended ceiling grid where the tile is replaced, perform the following steps. 1. Determine the location for mounting the enclosure and remove the appropriate ceiling tile.
8 Pelco Manual C467M-D (5/95) 12. Attach the safety chain on the side of the back box to the short 4-40 threaded screw in the 12.5" round faceplate trim with the provided hardware. 13. Attach the faceplate trim to the back box by align- ing the two serrated studs with two of the holes in the edges of the back box and engaging the studs.
Pelco Manual C467M-D (5/95) 9 12. Attach the faceplate trim to the back box by align- ing the two serrated studs with two of the holes in the edges of the back box and engaging the studs. 13. Operate the pan/tilt to verify that there are no ob- structions or dragging cables within the back box or dome.
10 Pelco Manual C467M-D (5/95) 5.0 CARE AND MAINTENANCE Regularly scheduled maintenance will prolong the op- erational life and appearance of the equipment. IMPORT ANT : The lower dome of the en- closure is an optical surface. When cleaning the inner surface of the dome and viewing window , treat as carefully as you would a fine camera lens.
Pelco Manual C467M-D (5/95) 11 6.0 EXPLODED ASSEMBL Y DIAGRAM Refer to Figure 7 for an exploded assembly diagram of the SB19 enclosure. Figure 7. SB19 Exploded Assembly Diagram PP ONL Y NON SL ONL Y *.
12 Pelco Manual C467M-D (5/95) 7.0 EXPLODED ASSEMBL Y MECHANICAL PARTS LIST Item Qty Description Pelco Part Number 1 1 UL, Pad, camera, black .062" thick EH200010004 2 1 PCB assembly , pan/tilt PCB3000100ASSY 3 1 Bushing, 3/8" tilt shaft PT180010001 4 1 Shaft, tilt table PT18004002COMP 5 1 Sprocket .
Pelco Manual C467M-D (5/95) 13 7.0 EXPLODED ASSEMBL Y MECHANICAL PARTS LIST (continued) Item Qty Description Pelco Part Number 48 Not used 49 Not used 50 Not used 51 1 Slip ring, 24 circuit for presets 250010000 52 Not used 53 Not used 54 Not used 55 1 Bracket, tilt pot PT18044012COMP 56 1 Bracket, LPP lens connector PT18044013COMP 57 1 Gear , 1.
14 Pelco Manual C467M-D (5/95) 8.0 MODELS DD1900 Dome drive unit for SB1900. (UL) DD1900-PP Dome drive unit for SB1900-PP . DD1900-SL Dome drive unit for SB1900-SL.
Pelco Manual C467M-D (5/95) 15 9.2 MODELS SB1900, SB1900-SL, SB1900-PP AND SB1900SL-PP CM7500 Series Coaxitron Matrix Switcher/Control System rack mount card cage with CPU and power supply . Capable of up to 64 inputs and up to 4 monitor outputs. (See C584 product specifi- cation sheet for details).
16 Pelco Manual C467M-D (5/95) Pan Speed: 24 ° /sec ± 1 ° T ilt: -9 0 ° movement from horizontal plane T ilt Speed: 12 ° /sec ± .5 ° Maximum Load: 10 lbs (4.
Pelco Manual C467M-D (5/95) 17 12.0 W ARRANTY AND RETURN INFORMA TION This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE).
18 Pelco Manual C467M-D (5/95) Pelco 3500 Pelco Way • Clovis, CA 93612-5699 (559) 292-1981 • (800) 289-9100 FAX (800) 289-9150 or (559) 292-3827 International customers call 1-559-292-1981 or FAX 1-559-348-1120 (Product specifications subject to change without notice.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pelco DD1900 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pelco DD1900 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pelco DD1900, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pelco DD1900 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pelco DD1900, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pelco DD1900.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pelco DD1900. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pelco DD1900 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.