Manuel d'utilisation / d'entretien du produit C3422M-B du fabricant Pelco
Aller à la page of 20
INST ALLATION C3422M-B (3/08) Pressurized Spectra ® IV Series Pendant Back Box with Fiber Optic Option.
2 C3422M-B (3/08) Preinstallation NOTE: This manual is designed to be a reference tool for th e installatio n of your s ystem. For best results and ease of installation, the dome system should be asse mbled, pressurized, and tested before installati on.
C3422M-B (3/08) 3 3. Loosen the V -band attached to the back box and let it hang to the side. Figure 3. Loosening the V-band 4. Prepar e the lowe r dome for installation : a. Remove the O-ring fro m the lower dome. b. Lightly appl y O-ring lubr icant (supp lied) to the O- ring.
4 C3422M-B (3/08) Figure 5. Attaching the Back Box Leash 6. Install the dome drive. Refer to T able A for a list of compatible do me drives and back boxes. a. Set the DIP switch es located on the base of the dome dr ive. Refer to t he labels locat ed on the base of the dome drive or to Switch Settings on page 12 .
C3422M-B (3/08) 5 7. Install the lower dome: a. Position the lo wer dome so tha t the blower duct inside the back box is between the studs att a ched to the insid e of the lower dome. b. Install the V-band a round the lower do me and then tighten th e fastener of the V -band.
6 C3422M-B (3/08) d. Refer to the Operation/Prog ramming manu al (C 341 2M) for ins tru ctio ns on how to view the current readings for temperature and pressure.
C3422M-B (3/08) 7 Site Installation 1. Feed a fiber optic cable (not supplied) an d the supplied wiri n g harness into the front of the mount and out the back of the mount. Connect the wire s as required. Refe r to T able B, T able C, and T able D on page 10, and T able E on page 11 for cable a nd wiring infor mation.
8 C3422M-B (3/08) Figure 10. Removing the Back Box Mounting Plate 3. Thread the wiring fro m the mount throug h the mounting plat e, and then attach the mounting plate to the mount. If outdoors, apply threa d compound (sup plied) to the t hreads on the mounting p late.
C3422M-B (3/08) 9 Figure 12. Attaching the Wire Harness Connector.
10 C3422M-B (3/08) . NOTES: • Input power f or the dome is 24 V AC only . Power consumpt ion is 73 V A per dome. • Use a 24 V AC transformer with a minimum of 100 V A.
C3422M-B (3/08) 11 T able E. Configuration of Wire Harness Pin Wire Color Function 9-Conductor Cable AB l a c k A l a r m 1 BR e d A l a r m 2 C White Alarm 3 DG r e e n A l a r m 4 EB r o w n A l a r m 5 F Orange Alarm 6 G Y ellow Alarm 7 H Violet Ground – Blue N ot Used 5-Conductor Cable J Black Relay N.
12 C3422M-B (3/08) Switch Settings WAR N IN G : If you are using Pelco D or Pelco P pr otocol control, your system may not oper ate if the baud rate and address swi tches are not set correc tly . The switches are set at the facto ry at the def aults for Pelco D protoc ol control (2400 bau d and address 1).
C3422M-B (3/08) 13 T able G. Switch Settings for SW1, Pelco P Protocol Control NOTE: For Coaxitron con trols, SW1 is no t used; set all switches t o the OFF pos ition.
14 C3422M-B (3/08) SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 71 ON ON ON OFF OFF OFF ON OFF 72 OFF OFF OFF ON OFF OFF ON OFF 73 ON OFF OFF ON OFF OFF ON OFF 74 OF.
C3422M-B (3/08) 15 SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 151 ON ON ON OFF ON OFF OFF ON 152 OFF OFF OFF ON ON OFF OFF ON 153 ON OFF OFF ON ON OFF OFF ON 154 O.
16 C3422M-B (3/08) SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 223 ON ON ON ON ON OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON 225 ON OFF OFF OFF OFF ON ON ON 226 OFF.
C3422M-B (3/08) 17 Specifications GENERAL Construction Back Box 316L stainless steel Dome Drive Aluminum, thermoplastic Lower Dome T rim Rin g 316L stainle ss steel Bubble Polycarbonate, 0 .09-inch thick V-Band 316L stainle ss steel Pressure Rel ief Brass Schrader V alve Brass Connector Nickel-plated steel Light Attenuat ion Smoked f/1.
18 C3422M-B (3/08) Input Power 24 V A C 73 VA nominal (with heater) 24 VDC 3 A nominal (with heater) Fuse 1.25 A Auxiliary Outputs 2 Alarm Inputs 7 5.9 (15.1) 11.6 (29.5) 10.6 (26.7) NOTE: VALUES IN PARENT HESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
PRODUCT W ARRANTY AND RETURN INFORMA TION WARRANTY Pelco will r epair or repla c e, without charge, any merchandise p roved defectiv e in material or wor kmanship for a period of one year after the date o f shipment.
W orldwid e Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pelco C3422M-B c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pelco C3422M-B - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pelco C3422M-B, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pelco C3422M-B va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pelco C3422M-B, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pelco C3422M-B.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pelco C3422M-B. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pelco C3422M-B ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.