Manuel d'utilisation / d'entretien du produit C2622M du fabricant Pelco
Aller à la page of 28
® INST ALLA TION FX82051 Unmanaged Ethernet Switch Five 10BASE-T/100BASE-TX Ports and One 100BASE-FX Fiber Port C2622M (2/07).
2 C2622M (2/07) Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Regulatory Not ices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C2622M (2/0 7) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings.
4 C2622M (2/07) The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
C2622M (2/0 7) 5 Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation.
6 C2622M (2/07) Product Overview DESCRIPTION The FX82051 unmanaged Ethernet switch provid es five 10BASE-T/100BASE-TX ports and one 100BASE-FX fiber port for the trans port of bidirectional Ethernet data. T wo fi bers are required to transport bidirectional data over th e fiber port.
C2622M (2/0 7) 7 • Designed to meet NEMA TS 2 and Caltrans traff ic signal control equipment standards for ambient operating temperature, mechanical shock and vibrati on, humidity with condensation,.
8 C2622M (2/07) FRONT PANEL Figure 2 illustrates the front panel of the FX82051 module. Figure 2. Front Panel of FX82051 Module For detailed information about t he front-panel LEDs, refer to T roubleshooting on page 17.
C2622M (2/0 7) 9 REAR PANEL Figure 3 illustrates the rear panel of the FX82051 module. Figure 3. Rear Panel of FX82051 Modul e (SC Fiber Connector Shown) For additional information about r ear -panel connections, refer to Installation on page 10. For detailed information about the RJ-45 LEDs, refer to T roubleshooting on page 17.
10 C2622M (2/07) Installation PACKAGE CONTENTS The following it ems are supplied: 1 FX82051 module 1 Regulated switching power suppl y with four plug adapt ers (North American, Australian, U.K., and European configurations); 100-240 V A C, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4 - 40 x 0.
C2622M (2/0 7) 11 Using the TX Mode switch for a parti cular port, y ou can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegoti.
12 C2622M (2/07) Ta b l e A . TX Mode Switch Settings TX Mode Switch Position 10BASE-T/100BASE-TX Modes of Operation 0 Auto Neg/Dis FC: Enables autonegotiation between 10 Mbps and 100 Mbps and between.
C2622M (2/0 7) 13 MOUNTING The FX82051 module can be mounted into a rack or c an be used as a stand-alone module. As a stand- alone module, the unit can be placed on a desktop or can be mounted to a wall.
14 C2622M (2/07) Mounting the FX82051 Module Using the W all Clip NOTE: Before mounting the FX82051 module to a wall, ens ure that there is adequate space at both ends for viewing the front-panel LEDs and for ma king the various rear- panel cable connections.
C2622M (2/0 7) 15 CONNECTIONS Connections to the FX82051 module are made on the rear panel of the modul e (refer to Figure 6). Figur e 6. FX82051 Module Connection s As illustrated in Figure 6, FX8205.
16 C2622M (2/07) Figure 7. Fiber Port Connections in Point-to-Point Application.
C2622M (2/0 7) 17 T roubleshooting LED indicators on the front and rear panels of the FX82051 module allow you to monitor operational status: • LED indicators on the front panel (refer to Fi gure 2) allow you to moni tor operating power , 100BASE-FX port status, and optic signal/laser status.
18 C2622M (2/07) Optic Fault LED ( ) Green The optical signal is being received and laser is operating properly . — No action required. Red The optical signal is not being received. Remote module is not powered on. Check power connections. Replace power supply if necessary .
C2622M (2/0 7) 19 Ta b l e C . T roubleshooting with Rear -Panel Indicators Indicator Color Meaning Possi ble Cause Corrective Action RJ-45 10BASE-T/100BASE-TX Port St atus LED - Left (Link/Activity) Amber A 10BASE-T link is established. — If 10BASE-T operation is desired, no action is required.
20 C2622M (2/07) RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued) Not lit A 10BASE-T or 100BASE-TX link cannot be established. A problem may exist with the cable: • Cable is not connected to the module or to the 10BASE-T/100BASE-TX compatible device.
C2622M (2/0 7) 21 RJ-45 10BASE-T/100BASE-TX Port St atus LED - Right (Duplex/Collision) Amber Port is set to 10BASE-T full- duplex mode. — If 10BASE-T full-duplex operation is desired, no action is required. If 10BASE-T full- duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port Modes of Operation on page 10 for information.
22 C2622M (2/07) RJ-45 10BASE-T/100BASE-TX Port Status LE D - Right (Duplex/Collision) (Continued) Green Port is set to 100BASE-TX full- duplex mode. — If 100BASE-TX full-duplex operation is desired, no action is required.
C2622M (2/0 7) 23 RJ-45 10BASE-T/100BASE-TX Port Status LE D - Right (Duplex/Collision) (Continued) Not lit Port is set to 10BASE-T half- duplex mode and no collisions are detected.* — If 10BASE-T half-duplex operation is desired, no action is required.
24 C2622M (2/07) Specifications PERFORMANCE Switch T ype Unmanaged Layer 2 Switch Method Store and forward Switch Fabric Non-head-of-line blocking Data Rate 10/100 Mbps Compliance IEEE 802.
C2622M (2/0 7) 25 OPTICAL POWER BUDGET , TRANSMISSION DIST ANCE, AND LASER CLASS 1 LIMIT Model Number Wavelength (T ransm it/Receive) Optical Power Budget Maximum T ransmission Distance Laser Class 1 Limit* Multimode (62.5/125 μm) FX82051MSTR-2 1310/1310 nm 26 dB † 6 km (3.
26 C2622M (2/07) Appendix. RJ-45 Connector Pinouts Figure 8 illustrates RJ-45 MDI/MDI-X connector pinouts. Figure 8. RJ-45 MDI/MDI-X Connector Pinouts T able D summarizes RJ-45 MDI/MDI-X connector pinouts.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or work manship for a period of one year after the date of shipment.
® Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pelco C2622M c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pelco C2622M - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pelco C2622M, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pelco C2622M va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pelco C2622M, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pelco C2622M.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pelco C2622M. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pelco C2622M ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.