Manuel d'utilisation / d'entretien du produit DGP2-641BL du fabricant Paradox Hellas S.A.
Aller à la page of 36
User Guide for the EVO96 DGP2-640 DGP2-641BL / DGP2-641RB DGP2-648BL.
.
T able of Content s Introduction ...................................................................... 1 Legend ............ ............................ ............ ...................... ....... 1 Basic Operation ..................................
User’s Manual 1 1.0 Introduction Y our EVO96 System is an advanced technology security system that will provide you with reliable security protection and powerful features that are easy to use. The elegant and user -friendly keyp ads will allow you easy access to your sec urity system's functions and information at the touch of a button.
2 EVO96 2.0 Basic Operation The following sections will introduce you to the roles of the buttons, lights, and messages on your keyp ad. Figure 1: DGP2-641BL/RB Basic Overview Figure 2: DGP2-648BL LED Keypad Overview 2.
User’s Manual 3 2.2 Visual Feedback The icons on the keypad’ s screen communicate your system’s status as outlined in T able 1. T able 1: Icon Display and Functionality T able 2: Additional Icon Ke ypad V isual Feedback ICON Icon(s) Display and Functionality Indicates numbers corresponding to zo nes and option numbers.
4 EVO96 For all keypads, the [ ENTER ] or [] key will save and exit, and the [ CLEAR ] or [] key will exit without saving. [ ENTER ] and [ CLEAR ] represent both the Icon’ s enter and clear keys and the LCD/LED keypads’ enter and clear keys unless both keys are shown to have a different function.
User’s Manual 5 3.0 Partitioned System Y our installer can set your keypad to recognize separate prot ected areas. A separated system is called a p artitioned system, which can be useful in situations where shared security system s are more practical.
6 EVO96 4.0 Arming When your system is armed, it can respond to any breach in the protected zones by causing an alarm and sending a report to your monitoring station. 4.1 Exit Delay Timer When you arm your system, it will trigger the Exit Delay T imer to provide you with enough time to exit the protected area before the system is armed.
User’s Manual 7 4.6 Bypass Programming Y ou can bypass certain zones when you arm t he protected area(s). When a zone is bypassed, it will be ignored the next time your system is armed. Once your area is disarmed, the system will unbypass the zone. T o Bypass a zone: 1.
8 EVO96 4.9 Auto-Arming If enabled by your installer , you can set the ti me that an area will arm itself automatically . 4.9.1 Timed Auto-Arming Y our installer can set T imed Auto-Arming to function in either Force or S tay arming mode.
User’s Manual 9 5.0 Disarming When your system is disarmed, it deactivates any alarms in progress, and it deactivates the zones so the alarm will not be triggered if zones are breached. 5.1 Entry Delay Timer Y our installer will program designated en try point s (i.
10 EVO96 6.0 Access Codes Access Codes allow access to the system. Y our system supports up to 999 user access codes. Codes are given a User Number between 002 and 999 (User Number 001 is the System Master Code). Y our installer will program user access codes to be four , six, or variables of one to six digit s in length.
User’s Manua l 11 6. Enter a user code. If the user code is of variable length, press the [ ENTER ] button after entering the user code. If necessary , assign an Access card (step 13 in section 6.6.1 on page 13) and User Label (section 6.4 on p age 1 1).
12 EVO96 [ DISARM ] = Numeric Keys / Alphanumeric Keys Every time the [ DISARM ] key is pressed it will toggle from numeric keys to alphanumeric keys and vice versa.
User’s Manua l 13 If the keypad emit s a rejection beep at any point during the programming procedure, you may have chosen an existing user code or you do not have access to certain User Options (section 6.7) and Area Assignments (step 7 in section 6.
14 EVO96 Option [1] : Access Control Option [2] : Can Disarm with Access Card Option [3] : Extended Unlocked Period Options [4] and [5] : Arming with Card [4] ON, [5] OFF:Regular Arm [4] OFF , [5] ON:.
User’s Manua l 15 Option [4] : Bypass When option [4] is ON , the Bypass feature is enabled. This feature allows the user to deactivate zones when arming the area(s). Option [5] : Arm Only When option [5] is ON , the Arm Only feature is enabled. The user can arm assigned areas with either a card or code, but cannot disarm.
16 EVO96 Option [6] : Add T olerance Window to Schedule When option [6] is ON , the Schedule T olerance Window feature is enabled. This feature extends a user ’s scheduled access period through an Access Control door by the amount programmed by your installer .
User’s Manua l 17 7.0 Using Access Control 7.1 Entering & Exiting Depending on how your system is installed and on the type of keyp ad, there are various ways to enter and exit Access Control doors: • Present your Access Control card to the reader or the DGP2-641RB keypad.
18 EVO96 7.3 How Access Control Works T o illustrate how Access Control functions, we will use three simple Access Control System examples: Figure 3: Example A Bonnie’s Access Control card is programmed with Access Level 01 and Schedule 01.
User’s Manua l 19 8.0 T rouble Display 8.1 T rouble Display If your system experiences any problems, Trouble(s) [TRBL] t o View or the trouble icon will appear on the screen, or the T RBL action light will illuminate. The T rouble Display will only display the troubles that occur in the area(s) to which the keyp ad has been assigned.
20 EVO96 8.1.5 Group 7: Zone Fault A wireless device is no longer communicating with its receiver , or a connection or CleanMe TM trouble is occurring with your smoke detectors. 8.1.6 Group 8: Clock Loss The time and date have been reset to the default.
User’s Manua l 21 9.0 Additional Features 9.1 Programmable Output s (PGMs) Y our system includes Programmable Outputs (PGMs) that can be programmed by your installer . A PGM triggers when a predetermined event or series of events occurs in your system.
22 EVO96 Figure 8: Modifying illuminati on settings on the DGP2-648BL 9.3 Set Time & Date T o reset the time and date: 1. Enter your [ ACCESS CODE ] and press the [ TRBL ] button or the [] key .
User’s Manua l 23 press and hold the button combinations displayed in T able 6 on page 23. Y our installer can program the alarm to be either silent or audible. T able 6: Panic Buttons 9.6 Quick Function Buttons Y ou will only need to use the Quick Function Buttons upon your installer’s or monitoring station's request.
24 EVO96 10.0 T esting and Maintenance 10.1 Burglar Alarm T esting T wo people are needed to complete this test. One person will watch the screen on the keypad while the other person walks around the protected areas and opens the zones (i.e. opens the doors and windows that are protected, walk in the path of the motio n detectors, etc.
User’s Manua l 25 1 1.0 Fire and Burglar Alarms 1 1.1 S tandard Fire Zone During a fire alarm, the bell/siren emits an intermittent sound ( BEEP - BEEP - BEEP ) until silenced or reset. If the zone is a S tandard Fire Zone, your system can immediately send an alert to your monitoring station.
26 EVO96 Figure 9: Delaye d Fire Zone 1 1.4 Minimizing Home Fire Hazards How can you avoid the three most common causes of fires at home? • N ever leave cooking food unattend ed. It’s the leading c ause of fire injuries. Cooking fires often result from unat tended cooking and human error , rather than mechanic al failure.
User’s Manua l 27 Appendix 1: Hebrew Special Characters Refer to the following tables when programming the user labels of a Hebrew LCD keypad. Instead of using T able 4 on page 1 1 and T able 5 on page 12, use T ables 9 and 10 below . Refer to section 6.
28 EVO96 Appendix 2: Russia n S pecial Characters Refer to the following tables when programming the user labels of a Russian LCD keypad. Instead of using T able 4 on page 1 1 and T able 5 on page 12, use T ables 1 1 and 12 below . Refer to section 6.
User’s Manua l 29 Appendix 3: Greek S pecial Characters Refer to the following tables when programming the user label s of a Greek LCD keypad. Instead of using T able 4 on page 1 1 and T able 5 on page 12, use T ables 13 and 14 below . Refer to section 6.
30 User’s Manual INDEX A Access Codes Deleting .................................................................................. 12 Labelling ......................................................................... ........ 11 Programming ........
EVO96 31 I Ignoring Zones when Arming, see Bypass Programming Instant Arming .................................................................................. 6 K Keypad, LCD Buttons ...................................................................
W arranty Paradox Security Systems Ltd. (“Seller”) w arrants its product s to be free from defects in materials and workmanship under norma l use for a period of one year .
For technical support in Canada or the U.S., call 1-800-791-1919 for English or 1-866-912-0600 for French, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST . For technical support out side Canada and the U.S., call 00-1-450-491-744 4, Monday to Friday from 8:00 a.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Paradox Hellas S.A. DGP2-641BL c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Paradox Hellas S.A. DGP2-641BL - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Paradox Hellas S.A. DGP2-641BL, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Paradox Hellas S.A. DGP2-641BL va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Paradox Hellas S.A. DGP2-641BL, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Paradox Hellas S.A. DGP2-641BL.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Paradox Hellas S.A. DGP2-641BL. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Paradox Hellas S.A. DGP2-641BL ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.