TECHNICAL & SER VICE MANU AL CZ-RD515U WIRED REMO TE CONTROLLER REFERENCE NO . SM 700883 Model No. CZ-RD515U Product Code No. 1 852 361 14.
• Before doing repair work, please read the " SAFETY PRECA UTIONS" carefully and fully understand them. • The precautionary items here are divided into " W arning" and " Caution" items.
W arning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle.
T able of Contents SAFETY PRECA UTIONS T ABLE OF CONTENTS 1. SPECIFICA TIONS 2. APPLICABLE INDOOR UNITS 3. FUNCTIONS 4. SELF-DIA GNOSTICS 4-1. Self-Diagnostics Procedure 4-2. Self-Diagnostics T able (Ceiling Cassette T ype) 4-3. Self-Diagnostics T able (W all Mounted T ype 1) 4-4.
1. SPECIFICATIONS 70.0 16.5 120.0 Item Signal Transmission Method Dedicated Remote Controller Cable DC5V supplied from Indoor Unit Liquid Crystal Set Temperature Indication (68 °F to 86 °F) Six Dire.
2. APPLICABLE INDOOR UNITS 3. FUNCTIONS When the unit is modified from one for wireless remote controller to that for wired remote controller, the following functions become unavailable.
4. SELF-DIA GNOSTICS PROCEDURE After turning on power to the air conditioner, use the remote controller and follow the steps below to execute self-diagnostics. Step 1: Press and hold the remote controller NIGHT SET BACK (NSB) button and 1 HR TIMER button.
4-2. Self-Diagnostics T able (Ceiling Cassette T ype) Since the indications cover various units, the corresponding parts listed below may not be present in some models.
4-3. Self-Diagnostics T able (W all Mounted T ype 1) REMOTE CONTROL receiver (1) OPERATION lamp (2) TIMER lamp (3) QUIET lamp OPERATION button INDOOR UNIT Since the indications cov er v arious units, the corresponding par ts listed below ma y not be present in some models.
4-4. Self-Diagnostics T able (W all Mounted T ype 2) (1) OPERATION lamp (2) TIMER lamp (3) OPERATION TIMER ON/OFF INDOOR UNIT Since the indications cov er v arious units, the corresponding par ts listed below ma y not be present in some models. INDICA TION ON INDOOR UNIT .
.
Operating Instructions CZ-RD515U (852-6-4181-230-00-1) APPENDIX A A-1.
Wired Remote Controller Model No. CZ-RD515U Operating Instructions Panasonic Corporation 1006 Kadoma, Kadoma City, Osaka, Japan 85264181230001 CV6233187877 This wired remote controller is designed for both the “COOL/DRY/HEAT Model” and “COOL/DRY Model” indoor unit.
2 FEA TURES • Micropr ocessor Co ntr olled Operation The interior comp ar tment of the remote controll er contains se v eral f eatures to facil itate automatic op eration, easy logicall y displa yed f or easy use. • 24-Hour ON or OFF Timer This timer can be set to automatically turn the unit on or off at any time within a 24 hour period.
3 INST ALLA TION LOCA TION W e recommend that this wired remote controller be installed proper ly b y qualified installation tec hnicians in accor dance with the Installa tion Instructions pro vided with the unit.
4 REMO TE CONTR OLLER Display Inf ormation on the operating condition s is displa yed while the remote controller is s witched on. If the unit is turned off, only the mode that w as set previously is still displayed. F AN SPEED selector button : The air conditioner automatically dec ides the fan spe eds.
5 Sensor A temperature sensor inside the remote controller senses the room temperature . ON/OFF operation b utton This bu tton is f or turning the air conditioner on and off .
6 REMO TE CONTR OLLER (DISPLA Y) (1) Operation mod e A UT O ................. ................... . (only f or COOL/DR Y/HEA T Model) HEA T .................. ................ .... (only f or COOL/DR Y/HEA T Model) MILD DR Y .......... ...............
7 OPERA TION WITH THE REMO TE CONTR OLLER 1. A utomatic Operation (only f or COOL/DR Y/HEA T Model) • Single use This unit automatically s witches betw een cooling operati on and heating operatio n according to the diff erence between the room temperature and the t emperature setting.
8 3. Adjusting the Fan Speed A. A utomatic fan speed Simply set the F AN SPEED selector b utton to the position. This automatically sets th e best fan speed for the room temperature. B. Manual fa n speed If you w ant to adjust fan speed manually during operation, just set the F AN SPEED selector button as desired.
9 SETTING THE TIMER 1. How to set the p resent time (Example) T o set to 9:10 pm. 2. How to set the OFF time (Example) T o stop the air conditioner at 11:30 pm. T o cancel the setting, press the TIMER SELECT button twice. 3. How to set the ON time (Example) T o star t operation at 7:10 am.
10 USING THE 1-HOUR OFF TIMER 1. 1-Hour OFF Timer This function causes the unit to operate for one hour and then stop, regar dless of whether the unit is on or off when this button is pressed. The indicator in the displa y i ndicates that this function is operating.
.
A-2 INSTALLATION INSTRUCTIONS (CZ-RD515U) CZ-RD515U (852-6-4190-592-00-0) APPENDIX B.
Parts supplied with the remote controller See T able 1. Remote controller installation guidelines Mount the remote controller 3.3 to 4.9 ft. (1 to 1.
2 A. Installing with in-wall junction box (1) Install the junction box (locally purchased) into the wall. (Figs. 2-a and 3) (2) Pass the wire harness through the junction box and conduit. (Fig. 3) (3) Insert a flathead screwdriver into the 5 tab locations and disconnect the back plate of the remote controller by lifting up slightly .
Fig. 8 Indicator Wire harness Ceiling panel T erminal cover Clamps 7P IND and 4P RC wiring connector 5P FLAP wiring connector Clamping strap FLAP RC IND 7P 4P 5P FLAP wiring connector Wire harness Rem.
4 Fig. 9 Fig. 10 Fig. 1 1 ON/OFF operation button 1 HR.TIMER button NIGHT SETBACK button ACL (Reset) button SENSOR button OPERA TION lamp TIMER lamp HIGH POWER lamp REMOTE CONTROL receiver OPERA TION .
.
A-3 CZ-RC515U (852-6-4190-590-00-0) APPENDIX C INSTALLATION INSTRUCTIONS Installing the Connection Kit for Wall-Mounted Models ().
Installing the connection kit A. 7000 BTU, 9000 BTU, and 12000 BTU inverter models (1) Remove the air intake grille. (2) Remove the terminal cover . Pull out the thermistor , then remove the grille. For details on steps (1) and (2), refer to the Installation Instructions included in the outdoor unit package.
(10) Pass the wire tube through the clamping strap, and temporarily fasten in place with the screw . Next, use a clamp and bind the wires together immediately above the clamping strap, and fasten in place with the screw in order to prevent pulling on the wire harness.
3 B. 18000 BTU and 24000 BTU inverter models (1) Remove the air intake grille. (2) Remove the terminal cover . Pull out the thermistor , then remove the grille. For details on steps (1) and (2), refer to the Installation Instructions included in the outdoor unit package.
4 Fig. 9 Fig. 10 Fig. 1 1 ON/OFF operation button 1 HR.TIMER button NIGHT SETBACK button ACL (Reset) button SENSOR button OPERA TION lamp TIMER lamp QUIET lamp How to T est Run the Air Conditioner After turning on the power of the air conditioner , use the remote controller and follow the steps below to conduct the test run.
.
A-4 INSTALLATION INSTRUCTIONS Installing the Connection Kit for Wall Mounted Type 2 CZ-RC515UA (852-6-4190-591-00-0) APPENDIX D ().
Parts included in the package See T able 1. T able 1 85264190591000 201 1 CV6233187891 Connection Kit INST ALLA TION INSTRUCTIONS Parts Figure Q'ty Parts Figure Q'ty Parts Figure Q'.
2 0RYHWKHMXPSHUFDSWR:')LJWKHQFRQQHFWWKHQRLVHILOWHU&RQQHFWRU $ 3WRWKH3&%VRFNHW/$03 DQ.
3 ,QVHUWWKHQRLVHILOWHULQWRWKHHOHFWULFDOER[WKHQIDVWHQWKHQRLVHILOWHU&RQQHFWRU%ZLUHDQGWKHZLUHKDUQHVVRIWKH ZLUHGUHPRWH.
4 How to T est Run the Air Conditioner $IWHUWXUQLQJRQWKHSRZHURIWKHDLUFRQGLWLRQHU XVHWKH UHPRWHFRQWUROOHUDQGIROORZWKHVWHSVEHORZWRFRQGXFW WKH.
.
DC1111-0.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Panasonic CZ-RD515U c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Panasonic CZ-RD515U - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Panasonic CZ-RD515U, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Panasonic CZ-RD515U va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Panasonic CZ-RD515U, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Panasonic CZ-RD515U.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Panasonic CZ-RD515U. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Panasonic CZ-RD515U ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.