Manuel d'utilisation / d'entretien du produit 1892 1335 du fabricant Orion Car Audio
Aller à la page of 37
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 1 ORION RADIO MODEM WITH I/O OPERATING INSTRUCTIONS 1892 1335 THIS IS A DRAFT VERSION OF THE MANUAL.
2 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 OVERVIEW The Orion is a radio modem with on-board telemetry inputs and outputs. It is available in a number of different versions to suit different applications, and has many user- programmable features, which may be locally or remotely set.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 3 v One-to-one or master + outstations configuration v Outstations can be polled, or volunteer data when thresholds are reached (‘alarms’).
4 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 OPTIONS WHEN ORDERING Many options are user-programmable, but the options below must be specified when ordering so that the correct version of the Orion can be supplied: OEM PCB version The Orion is available uncased as a PCB for mounting in OEM equipment.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 5 INSTALLATION Physical The cased version may be used freestanding or fixed using the four holes provided: Figure 4 - Orion (case.
6 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 Figure 6 - Dimensions of Orion PCB (mm) Figure 7 - Required mounting clearances for Orion PCB.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 7 Connections Power Front panel, locking power plug, 2 pole with 2.1mm centre pin. Centre conductor: +9 to +15V DC Outer conductor: 0V (connected to unit ground) Antenna Female BNC, 50 O Antenna connection for both transmit and receive.
8 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 Serial Port 9-way D-type male connector - NOT a standard serial port v Protocol (RS232, RS422 or RS485) is fixed by soldered links. See page 10. Pin No RS232 RS422 RS485 1 SHDN Modem on/off input If < 0.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 9 Graphical User Interface (GUI) The GUI is a program which runs on a PC under Windows, and provides a simple and convenient way to set up local or remote units before use.
10 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 SETTING UP AN ORION The Orion has some options which are chosen when it is ordered (see page 4) and many which you can configure yourself with hardware links, or soft-configure using data commands.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 11 Links can be closed with a solder blob as shown in Figure 10 to select these options: Option Choice Links Protocol RS232 LK1 o.
12 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 Figure 11 - Orion GUI window Note the set of tabs at the top which set the Orion up. The tabs at the bottom are used to set up in/out functions, and also to monitor and control during operation.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 13 COM Ports and General Status Figure 12 - COM Port tab This tab is the first one which the GUI presents to you, because the GUI must be set to the same baud rate and parity as the port on the Orion in order to communicate with it.
14 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 v FLASH FACTORY SETTINGS CORRUPT! (Error code 4) When the modem was first programmed at the factory, a backup factory settings table was written in the FLASH memory. This is used if it is necessary to invoke the Reprogram with Factory Settings command.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 15 TS is the basic two-way link for asynchronous RS232 data. It has no error correction. TU also provides a two-way asynchronous RS232 data link, but it has Feed-forward Error Correction (FEC) so that many errors can be corrected.
16 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 TOR TOT Single outstation. The master is configured as TOR, and the outstation as TOT. Data input at the outstation is output at the master’s normal data port, I/O ???and alarm messages are output on the secondary data port.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 17 No. of retries (TP mode only) If a received packet fails its CRC check, the receiving modem will ask for retransmission. For each packet, this will be repeated until either a good copy is received, or the number of retries set here has been reached.
18 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 This space reserved for additional material.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 19 Telemetry Option Configuration Depending on which mode you are using the Orion unit in, you may need to set up other options such as alarm levels. v These options are not relevant if you are using the unit as a straight modem.
20 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 For each input, select: Alarm: enable disable Alarm validation period: 1 to 255 - time for which condition must persist (in 10.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 21 This space reserved for additional material.
22 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 OPERATION LED Indications Three LED indicators are visible on the front panel, with the following meanings: Yellow Status Slow blink (every 2 seconds) indicates normal operation.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 23 APPENDIX A: AT COMMAND CODES Normally the GUI is the best way to configure, control and interrogate a local Orion unit.
24 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 OK <CR><LF> The modem is now ready to be configured. v Transmission and reception are blocked during Command Mode.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 25 The current value of most parameters can be found out by adding a question mark to the end of the code which sets it, for example: ATB1? <enter> to which the modem responds 1 <CR><LF> Capital letters MUST be used for all command instructions.
26 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 AT&F= Set operating frequency directly xxxx.xxxxxxx MHz AT&F? Read operating frequency AT&W Save to EEPROM AT&.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 27 ATI10=0 Turn all test modes off ATI10? Return whether any test is active 0 or 1 0 = no tests active 1 = one or more tests active ATO End command mode (Letter O, not zero).
28 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 ATS166? Get Sync tolerance 2 4 mismatches 3 6 mismatches ATS167= Set Inverted Symbol 0 None invert 1 TX invert ATS167? Get Inv.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 29 ATS182= Set power supply trip level 0 to 1023 ADC level ATS182? Read power supply level ATS183= Set delay after last packet 0 to 65535 delay *100ms ATS183? Read delay after last packet ATS184= Set no.
30 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 APPENDIX B: OVER-AIR COMMAND CODES Normally the GUI is the best way to configure, control and interrogate a remote Orion unit.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 31 Messages from Base Station to Outstation: 04 IDS IDD 20 CH Poll outstation IDD Note: IDS = 0 for base station 04 IDS IDD 21 nn.
32 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 04 IDS IDD 45 CH Read pulse count (which will reset counter) 04 IDS IDD 46 CH Read radio channel and TX setting 04 IDS IDD 47 .
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 33 Messages from Outstation to Base Station 04 IDS IDD 50 bbbb CH Reply to poll with bbbb = battery ADC level (reply to 20 comman.
34 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 04 IDS IDD 60 aaaa bbbb cccc dddd CH Analogue input levels (reply to 40 command) aaaa = ADC level of analogue input 0, 1 - 102.
1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 35.
36 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006 APPENDIX C: ATT? PARAMETER STRING STRUCTURE The modem responds to the ATT? command by sending a comma-separated list of all available parameters used for the selected modem mode.
Wood & Douglas Ltd, Lattice House © Wood & Douglas Ltd 2006 Baughurst, Tadley, Hants, RG26 5LP Tel:+44 (0)118 981 1444 Fax: +44 (0)118 981 1567 email: sales@woodanddouglas.co.uk website: www.woodanddouglas.co.uk 1892 1335 - Orion Radio Modem Operating Instructions - v1.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Orion Car Audio 1892 1335 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Orion Car Audio 1892 1335 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Orion Car Audio 1892 1335, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Orion Car Audio 1892 1335 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Orion Car Audio 1892 1335, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Orion Car Audio 1892 1335.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Orion Car Audio 1892 1335. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Orion Car Audio 1892 1335 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.