Manuel d'utilisation / d'entretien du produit HR-102 du fabricant Oregon Scientific
Aller à la page of 16
1 GB BASIC HEAR T RA TE MONIT OR MODEL NO.: HR102 USER’S MANUAL SECTION 1 INTRODUCTION Congratulations on your purchasing the HR102 Basic Heart Rate Monitor. The HR102 is a very useful healthcare product to help you achieve and maintain your optimum exercise zone by monitoring your heart rate in working out.
2 GB 50% 60% 70% 80% 90% 100% The upper and lower heart rate limits are calculated by multiplying your MHR by the percentages of the selected training zone.
3 GB - The aerobic exercise zone increases strength and endurance. It works within the body’s oxygen intake capability , burns more calories and can last longer. - The anaerobic exercise zone generates speed and power. It works at or above the body’s oxygen intake capability , builds more muscle and cannot be maintained for a long time.
4 GB 3. SET BUTTON Changes a value in the setting mode or turns on or off the alarm clock in alarm clock mode, reset stop watch 4. ST/SP BUTTON Starts or stops the stopwatch 5.
5 GB THE RECEIVER The receiver comes in the format of a wrist watch. Y ou can wear it on your wrist or strap it to your bike or exercise machine. Y ou can also obtain a mounting bracket from your authorized dealer. EFFECTIVE RANGE The transmitter and receiver will start transmitting and receiving signals once batteries are in place.
6 GB SECTION 2 OPERA TION THE BACK LIGHT Press LIGHT to turn on the back light for five seconds. OPERA TING MODES There are four operating modes, see FIG. A NOTE : When no signals are received or the measurement is out of range for five minutes, the receiver will disable the function and return to the previous operating mode automatically .
7 GB T o display the date, see FIG. E T o set the alarm, see FIG. F NOTE : When the alarm clock is activated, it will go off at the set time every day . Press any button to stop the alarm for the day . The alarm clock is still active and will set off again the following day .
8 GB 3. Replace the battery compartment door. 4. Open the transmitter battery lid with a coin by turning counterclockwise. 5. Insert one CR2032, 3V lithium battery with writing facing you. Note: Take care not to touch the two contacts, otherwise the battery can discharge.
9 GB - Do not mix fresh and old batteries, or batteries of different specifications. SPECIFICA TIONS Function Real time clock : 12/24 hour with hour / minute / second Stopwater : 00:00:00 to 29:59:59 (hrs : min : sec) Heart rate measurement : 30 - 240 bpm Upper limit : 80 - 240 bpm Lowr limit : 30 - 220 bpm W eight : W atch - approx.
10 GB CAUTION — The content of this manual is subject to change without further notice. — Due to printing limitation, the displays shown in this manual may differ from the actual display . — The contents of this manual may not be reproduced without the permission of the manufacturer.
11 GB GB LEGEND : ITALIC - P R E S S ITALIC - PRESS AND HOLD - F AST INCREAMENT F LEGENDE : ITALIQUE - APPUYEZ ITALIQUE - APPUYEZ, PUIS GARDEZ ENFONCEE - DEFILEMENT RAPIDE D LEGENDE : KURSIV - DRÜCKE.
12 GB [FIG. A].
13 GB [FIG. B] [FIG. C].
14 GB [FIG. D].
15 GB [FIG. E] [FIG. F].
16 GB [FIG. G].
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Oregon Scientific HR-102 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Oregon Scientific HR-102 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Oregon Scientific HR-102, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Oregon Scientific HR-102 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Oregon Scientific HR-102, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Oregon Scientific HR-102.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Oregon Scientific HR-102. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Oregon Scientific HR-102 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.