Manuel d'utilisation / d'entretien du produit BAR988HG du fabricant Oregon Scientific
Aller à la page of 28
Slimline Weather Station Model: BAR988HG / BAR986HG User Manual BAR988HG English Cover R5 OP 8/20/04, 11:26 AM 1 Black.
EN 1 CONTENTS Introduction .............................................................. 3 Product Overview .................................................... 4 Front View .............................................................. 4 Back View .
EN 2 Backlight ................................................................. 22 Reset System ......................................................... 22 Safety and Care ...................................................... 22 Warnings ..........
EN 3 NOTE INTRODUCTION Thank you for selecting the Oregon Scientific TM BAR988HG / BAR986HG Slimline Weather Station. This powerful device bundles time keeping, weather monitoring, indoor and outdoor temperature and humidity readings, barometric trends and altitude adjustment, into a single tool you can use from the convenience of your home.
EN 4 PRODUCT OVERVIEW FRONT VIEW 1. LCD display 2. MODE: Change settings / display 3. MEMOR Y : View current, maximum and minimum temperature / humidity / UV readings 4. HISTOR Y : View historical barometer and UV readings 5. ALARM / : View alarm status; set alarm 6.
EN 5 1. V entilation holes 2. Battery compartment (bottom) 3. AC adaptor socket 4. ° C / ° F switch (in battery compartment) 5. RESET button (in battery compartment) 6.
EN 6 LCD DISPLA Y 1. Weather Forecast Area: Animated weather forecast 2. T emperature / Humidity / Comfort Zone Area: Readings and trend lines; comfort zone; sensor channel number 3. UVI / Barometer Area: UV level and barometric pressure bar chart; UV Index and barometric readings 4.
EN 7 Weather Forecast Area 1. Low battery icon for main unit 2. AC adaptor icon - displays when unplugged 3. Weather display 1 2 3 T emperature / Humidity / Comfort Zone Area 1. Selected Area icon 2. T emperature trend 3. Channel number (1-5) / reception status 4.
EN 8 UVI / Barometer Area 1. Barometric pressure is showing 2. UV is showing 3. Low battery icon for UV sensor 4. UVI value is showing 5. UV exposure time countdown has started 6. UV index level 7. UV exposure time for user 8. Barometer / UV chart 9. SPF applied to user for UV exposure 10.
EN 9 REMOTE SENSOR (RTGR328N) 1 2 3 1. LCD display 2. LED status indicator 3. V entilation duct 1 4 5 6 7 2 3 1. Signal reception 2. Channel number 3. Low battery icon 4.
EN 10 GETTING ST ARTED BA TTERIES Batteries are supplied with this product: • Main unit 4 x UM-4 (AAA) 1.5V • Remote unit 2 x UM-3 (AA) 1.5V Insert batteries before first use, matching the polarity as shown in the battery compartment. For best results, install batteries in the remote sensor before the main unit.
EN 11 It is recommended that you use alkaline batteries with this product for longer performance. NOTE UNIT LOCA TION Main Weather Forecast Area Remote T emperature / Humidity Area UV Sensor UVI / Barometric Pressure Area AC ADAPT OR (MAIN UNIT) The batteries serve as a back-up power supply .
EN 12 SWITCH OPTION Channel If you are using more than one sensor , select a different channel for each sensor . Radio Signal Format EU (DCF) / UK (MSF) 4.
EN 13 The transmission range may vary and is subject to the receiving range of the main unit. Y ou may need to experiment with various locations to get the best results. SENSOR DA T A TRANSMISSION Data is sent from the sensor(s) every 60 Seconds. The reception icon shown in the T emperature / Humidity Area indicates the status.
EN 14 RADIO-CONTROLLED CLOCK The time and date are automatically updated by radio- controlled clock signals from official time-keeping organizations in Frankfurt (Germany) and Rugby (England) unless you disable this feature. The signals are collected by the remote sensor (RTGR328N) whenever it is within 1500 km (932 miles) of a signal.
EN 15 RF clock disabled: SET CLOCK Y ou only need to do this if you have disabled the radio- controlled clock, or if you are too far from a RF signal. 1. Press SELECT to navigate to the Clock Area. will show next to the Area. 2. Press and hold MODE for 2 seconds.
EN 16 SET PRE-ALARM The Pre-Alarm can be set to sound 15, 30, 45, or 60 minutes before the Daily Alarm. It will sound whenever the recorded temperature from Channel 1 Sensor falls to 2 ° C (35.
EN 17 Barometric data is shown in 2 areas at the bottom of the display . The upper area shows a 24-hour bar chart. The lower area shows current and historical readings. SELECT MEASUREMENT UNIT Slide the m b / i n H g switch (in the clock battery compartment), to change the display unit.
EN 18 3. Press UP or DOWN to set the altitude in 10-metre increments (-100m to 2500m). 4. Press HISTOR Y to confirm. WEA THER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius. The forecast is based on barometric pressure trend readings.
EN 19 • UVI Danger Alert when UV Index reaches unsafe levels. UV data is shown in the same area as the Barometer . Press SELECT to navigate to the Barometer Area, then press MODE to display the UV icon and data. Refer to the UVR138 User Manual for more information and see below to learn about the new additional UV features.
EN 20 The UV sensor must be activated before you try and set the additional features. Please refer to the UVR138 User Manual for more information. TEMPERA TURE AND HUMIDITY The weather station can display the following information from any of the 5 remote sensors: • Current, minimum, and maximum temperatures and relative humidity percentages.
EN 21 TEMPERA TURE AND HUMIDITY TREND The trend lines are shown next to the temperature and humidity readings. COMFORT ZONE The Comfort Zone indicates how comfortable the climate is, based on current temperature and humidity measurements.
EN 22 BACKLIGHT Press SNOOZE / LIGHT to illuminate the backlight for 8 seconds. RESET SYSTEM The RESET button is located at the bottom of the unit. Press RESET when you change the batteries and whenever performance is not behaving as expected (for example, unable to establish radio frequency link with remote unit or radio-controlled clock).
EN 23 TROUBLESHOOTING SPECIFICA TIONS Main Unit Dimensions L x W x H 120 x 86 x 188 mm (4.72 x 3.39 x 7.40 inches) Weight 376 grams (0.83 lbs) without battery Remote Unit Dimensions L x W x H 70 x 24.5 x 1 16 mm (2.76 x 0.96 x 4.57 inches) Weight 108 grams (0.
EN 24 Comfort 40% to 70% Memory Min / max Barometer Unit mb / hPa or inHg Resolution 1 mb (0.03 inHg) Altitude -100 to 2500 metres (-328 to 2734 feet) Display Sunny (day / night), partly cloudy (day /.
EN 25 ABOUT OREGON SCIENTIFIC Visit our website (www .oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children's electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones.
EN 26 EC-DECLARA TION OF CONFORMITY This product contains the approved transmitter module that complies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / EC Directive, if used as intended and the following standards have been applied: Safety of information technology equipment (Article 3.
© 2004 Oregon Scientific. All rights reserved. 086-003590-014 BAR988HG English Back R5 OP 8/20/04, 11:26 AM 1 Black.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Oregon Scientific BAR988HG c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Oregon Scientific BAR988HG - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Oregon Scientific BAR988HG, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Oregon Scientific BAR988HG va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Oregon Scientific BAR988HG, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Oregon Scientific BAR988HG.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Oregon Scientific BAR988HG. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Oregon Scientific BAR988HG ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.