Manuel d'utilisation / d'entretien du produit 564 SS du fabricant Omnitron Systems Technology
Aller à la page of 28
564 SS F i r e p l ace • Operation • Maintenance Tested and Listed by OMNI-Test Laboratories, Inc. Beaverton, Oregon Report # 028-F-80-5 ANSI Z21.88a-2003 WARNING: I f the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
2 Introduction © Travis Industries 4070626 100-01189_000 Introduction We welcome you as a new owner of a 564 SS gas fireplace. This manual details operation and maintenance of this fireplace. Please familiarize yourself with the Owner's Manual before operating your heater and save the manual for future reference.
Introduction 3 © Travis Industries 4070626 100-01189_000 Table of Contents Introduction and Important Information Introduction ............................................................. 2 Important Information .....................................
4 Safety Precautions © Travis Industries 4070626 100-01189_000 IF YOU SMELL GAS: * Do not light any appliance * Extinguish any open flame * Do not touch any electrical switch or plug or unplug anythi.
Safety Precautions 5 © Travis Industries 4070626 100-01189_000 Do not place clothing or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it.
6 Operation © Travis Industries 4070626 100-01189_000 Before You Begin • Read this entire manual before you use your new fireplace (especially the section "Safety Precautions" on pages 4 & 5). Failure to follow the instructions may result in property damage, bodily injury, or even death.
Operation 7 © Travis Industries 4070626 100-01189_000 Starting The Pilot Flame The pilot flame is required to ignite the main burners (it also plays a safety role). It should be left on once lit. It will stay lit unless the gas control valve is turned to "OFF".
8 Operation © Travis Industries 4070626 100-01189_000 Starting the Fireplace for the First Time • Burn the heater at a high setting with the blower off for an extended period (up to 48 hours). This will cure the painted surfaces. Fumes from the paint curing and oil burning off the steel will occur.
Operation 9 © Travis Industries 4070626 100-01189_000 Adjusting the Optional Blower Speed The blower helps transfer heat from the heater into the room. It will not turn on until the heater is up to temperature (approximately 10 minutes after starting).
1 0 Maintenance © Travis Industries 4070626 100-01189_000 Maintaining Your Fireplace's Appearance Fingerprints or other marks left on the optional plated surface may become etched in place if they are not wiped clean prior to turning the fireplace on.
Maintenance 1 1 © Travis Industries 4070626 100-01189_000 Grill Installation and Removal Follow the directions below to install. Upper Grill Installation (FPX and Avalon) Hold the grill at an angle and insert the lower slot over the lower bushing on the fireplace (both sides) Swing the grill upwards to engage the upper slot.
1 2 Maintenance © Travis Industries 4070626 100-01189_000 Face Installation and Removal Some fireplaces have a face that fits over the glass frame. The face can be removed following the directions below. Phillips Screwdriver Four screws hold the face in place.
Maintenance 1 3 © Travis Industries 4070626 100-01189_000 Glass Frame Removal and Installation Warning: The appliance must be completely cool before removing the glass.
1 4 Maintenance © Travis Industries 4070626 100-01189_000 Glass Frame Removal and Installation (continued) The latch can come loose from the latch assembly. This occurs only when it is rotated. Follow the directions below to re-install the latch if it comes loose.
Maintenance 1 5 © Travis Industries 4070626 100-01189_000 Log Set Installation Log Set Overview When installed, the logs should appear as shown below.
1 6 Maintenance © Travis Industries 4070626 100-01189_000 Rear Log Installation The rear log has a flat notch on both sides that center it on the grate. Place the rear log on the grate and slide it all the way back until the log contacts the end- brackets on the grate.
Maintenance 1 7 © Travis Industries 4070626 100-01189_000 Right Log Installation The left log has a groove that fits over the grate. Note how the left side of the log rests on the burner but does not cover any burner holes.
1 8 Maintenance © Travis Industries 4070626 100-01189_000 Left Log Installation The left log has a groove that fits over the grate. Note how the right side of the log rests on the burner but does not cover any burner holes.
Maintenance 1 9 © Travis Industries 4070626 100-01189_000 Left Twig Installation The left twig should be positioned so the front edge contacts the grate as shown above.
2 0 Maintenance © Travis Industries 4070626 100-01189_000 Right Twig Installation The right twig has two holes for the pins on the rear and right log.
Maintenance 2 1 © Travis Industries 4070626 100-01189_000 Ember Installation A bag of embers is provided to further enhance the firebox. Place the embers on the firebox floor and on the burner. Do not place embers over any of the burner holes or air channels.
2 2 Maintenance © Travis Industries 4070626 100-01189_000 Glass Cleaning The glass may be cleaned with a non- abrasive cleaner. To clean the inside of the glass, simply remove the glass frame, place it on a non-scratching surface, and clean the inside surface.
Maintenance 2 3 © Travis Industries 4070626 100-01189_000 Troubleshooting Table Problem: Possible Cause: Don't Call for Service Until You: Pilot Will Not Light A gas shut off valve is turned off.
2 4 Maintenance © Travis Industries 4070626 100-01189_000 How this Fireplace Works This fireplace was designed with safety as the primary concern. Many of the components inside this fireplace are for safety purposes. Therefore, only certified gas service technicians should service this fireplace.
Maintenance 2 5 © Travis Industries 4070626 100-01189_000 Wiring Diagram Millivolt Wiring (stock configuration) Orange White Piezo Igniter Thermopile Red Thermocouple Copper Co-Axial Wire Red Optiona.
2 6 Limited 7 Year Warranty © Travis Industries 4070626 100-01189_000 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed Warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC.
Optional Equipment 2 7 © Travis Industries 4070626 100-01189_000 Accessories The accessories listed below are available at your Travis dealer. To locate a dealer, visit: www.travisproducts.com Blower The optional blowers help transfer heat to your home.
2 8 Index © Travis Industries 4070626 100-01189_000 Index Accessories .......................................................2 7 Adjusting the Flame Height ....................................8 Adjusting the Optional Blower Speed ....................
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Omnitron Systems Technology 564 SS c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Omnitron Systems Technology 564 SS - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Omnitron Systems Technology 564 SS, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Omnitron Systems Technology 564 SS va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Omnitron Systems Technology 564 SS, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Omnitron Systems Technology 564 SS.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Omnitron Systems Technology 564 SS. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Omnitron Systems Technology 564 SS ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.