Manuel d'utilisation / d'entretien du produit OMG-COMM232-PCI du fabricant Omega Vehicle Security
Aller à la page of 22
www .omega.com e-mail: info@omega.com U ser ’ s Guide OMG-COMM232-PC I Dual Por t PCI RS-232 Inter face Board Shop online at.
Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
Contents I NTRODUCTION ..........................................................................1 O VERVIEW ................................................................................................ 1 W HAT ’ S I NCLUDED .....................
A PPENDIX F - C OMPLIANCE N OTICES .....................................16 F EDERAL C OMMUNICATIONS C OMMISSION S TATEMENT ............ 16 EMC D IRECTIVE S TATEMENT ........................................................... 16 Figures Figure 1 - Clocking Mode 'Divide By 4’ .
Introduction Omega Engineering COMM+232.PCI Page 1 Introduction Overview The Omega Engineering OMG - COMM+232.PCI is a two channel PCI Bus serial I/O adapter for the PC and compatibles. It provi des two RS-232 serial ports supporting data rates up to 460.
Card Setup Omega Engineering COMM+232.PCI Page 2 Card Setup Address and IRQ selection The OMG - COMM+232.PCI is automatically assigned I/O addresses and IRQs by your motherboard BIOS. Only the I/O address may be modified by the user. Adding o r removing other hardware may change the assignment of I/O addresses and IRQs.
Card Setup Omega Engineering COMM+232.PCI Page 3 To double these rates up to a maximum rate of 230.4K bps place the jumper in the divide by 2 (silk - screen DIV2) position.
Notes Page Omega Engineering COMM+232.PCI Page 4.
Card Setup Omega Engineering COMM+232.PCI Page 5 To select the maximum data rate (460.8K bps) place the jumper in t he divide by 1 (silk - screen DIV1) position.
Notes Page Omega Engineering COMM+232.PCI Page 6.
Installation Omega Engineering COMM+232.PCI Page 7 Installation Operating System Installation Windows 95/98/NT Run Setup on Disk 2 of the Serial Utilities Software. Windows 3.1x Refer to the Win3x.hlp file in the Win31 directory on D isk 1 of the Serial Utilities Software.
Technical Description Omega Engineering COMM+232.PCI Page 8 Technical Description The Omega Engineering OMG - COMM+232.PCI provides a PCI interface adapter with 2 asynchronous serial ports providing a versatile interface for modems, printers and plotters.
Technical Description Omega Engineering COMM+232.PCI Page 9 polling’. This method required the interrupt service routine to ‘poll’ or interrogate each UART as to its interrupt pending status.
Specifications Omega Engineering COMM+232.PCI Page 10 Specifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F) - 20º to 70º C (- 4º to 1 58º F) Humidity Range 10 to 90% R.H. Non - Condensing 10 to 90% R.
Appendix A - Troubleshooting Omega Engineering COMM+232.PCI Page 11 Appendix A - Troubleshooting A Serial Utility Diskette is supplied with the Omega Engineering adapter and will be used in the t roubleshooting procedures.
Appendix B - How To Get Assistance Omega Engineering COMM+232.PCI Page 12 Appendix B - How To Get Assistance Please refer to Appendix A - Troubleshooting prior to calling Technical Suppor t. 1. Read this manual thoroughly before attempting to install the adapter in your system.
Appendix C – Electrical Interface Omega Engineering COMM+232.PCI Page 13 Appen dix C - Electrical Interface RS - 232 Quite possibly the most widely used communication standard is RS - 232. This implementation has been defined and revised several times and is often referred to as RS - 232 or EIA/TIA - 232.
Appendix D - Asynchronous Communications Omega Engineering COMM+232.PCI Page 14 Appendix D - Asynchronous Communications Serial data communications implies that indiv idual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character.
Appendix E - Silk - Screen Omega Engineering COMM+232.PCI Page 15 Appendix E - Silk - Screen 5.0" 4.2".
Warranty Omega Engineering COMM+232.PCI Page 16 Appendix F - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules.
W ARRANTY / DISCLAIMER OME GA ENGINEERING, INC. war rants this unit to be free of defects in materials and workmanship for a period of 1 3 months from date of purc hase. OM E G A ’ s W ARRAN TY adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time.
M 3107 /0303 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE Thermocouple, RTD & Thermistor Probes, .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Omega Vehicle Security OMG-COMM232-PCI c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Omega Vehicle Security OMG-COMM232-PCI - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Omega Vehicle Security OMG-COMM232-PCI, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Omega Vehicle Security OMG-COMM232-PCI va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Omega Vehicle Security OMG-COMM232-PCI, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Omega Vehicle Security OMG-COMM232-PCI.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Omega Vehicle Security OMG-COMM232-PCI. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Omega Vehicle Security OMG-COMM232-PCI ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.