FPDM1000 SERIES Positive Displacement Mechanical Flowmeters.
.
Please read this information carefully befor e use! Before use, confirm the fluid to be used is compatible with the meter or consult with OMEGA for advice. To prevent damage fr om dirt or foreign matter , OMEGA recommends a Y or bas- ket type 60 mesh strainer be installed as close as possible to the inlet side of the meter .
1. OMEGA recommends that when set- ting up pipework for meter installations, a bypass line be included in the de- sign. This provides the facility for a meter to be removed for maintenance without interrupting production. (See Figure 1) 2 NOTE: Incorrect installation can cause pr e- mature wear of meter components 7.
3 OPERA TION SERVICE INSTRUCTIONS When fluid passes through the meter , the ro tors tur n. The gear located on top of one of the rotors drives the mechanical r egis- ters gear train which provides an accurate r eadout.
4 Check rotor operation by turning either of the rotors. If the r otors are not in mesh correctly or do not move fr eely , remove one of the rotors and r eplace it correctly at 90 degrees to the other r otor . Recheck the operation of the rotors. 4. Inspect the gears in the meter cap for wear .
5 Symptom Probable Cause Corrective Action FLUID WILL NOT 1. Foreign matter blocking Dismantle meter , clean rotors. Strainer must FLOW THROUGH rotors be fitted in-line. THE METER 2. Line strainer blocked Clean strainer . 3. Damaged rotors Replace rotors.
6 4 3 2 1 20 * 21 * 7 10 11 13 12 14 15 16 17 8 / 9 8A / 9A O-Ring Only 5 6 METER P ARTS LISTING Model: FPDM1004 Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS298N Meter Body 1/2 in. NPT (Aluminum) 11 MS337N Meter Body 1/2 in.
7 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 1 to 30 / 0.26 to 8 Below 5 centipoise 3 to 25 / 0.8 to 6.6 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e 3450 kPa / 500 PSI / 34.
8 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS188N Meter Body 1 in. NPT (Aluminum) 11 MS186N Meter Body 1 in. NPT (Stainless Steel) 11 MS188F Meter Body 1 in. ANSI 150 lb. Flange (Aluminum) 11 MS186F Meter Body 1 in.
9 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 6 to 120 / 1.6 to 32 Below 5 centipoise 10 to 100 / 2.6 to 26 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e 3450 kPa / 500 PSI / 34.
10 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS192N Meter Body 1 1 / 2 in. NPT (Aluminum) 11 MS190N Meter Body 1 1 / 2 in. NPT (Stainless Steel) 11 MS192F Meter Body 1 1 / 2 in. ANSI 150 lb.
11 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 10 to 250 / 2.6 to 66 Below 5 centipoise 15 to 235 / 4 to 62 Accuracy of Reading ± 1% Maximum Viscosity * 1000 C.
6 2 10 11 13 12 14 15 16 17 8 / 9 8A / 9A O-Ring Only 5 4 3 1 1 10 20 * * 7 5 12 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS520N Meter Body 2 in. NPT (Aluminum) 11 MS520-1N Meter Body 2 in.
13 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 15 to 350 / 3.96 to 92.46 Below 5 centipoise 30 to 300 / 7.93 to 79.
.
.
.
.
M- 4103/ 04 05.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Omega FPDM1000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Omega FPDM1000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Omega FPDM1000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Omega FPDM1000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Omega FPDM1000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Omega FPDM1000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Omega FPDM1000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Omega FPDM1000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.