Manuel d'utilisation / d'entretien du produit OMG-CONV-485-ISO du fabricant Omega Engineering
Aller à la page of 25
www .omega.com e-mail: info@omega.com U ser ’ s Guide OMG-CON V -485-IS O Isolated RS-232 to RS-422/485 Conver ter Shop online at.
Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
Contents INTRODUCTION .......................................................................................................... 1 O VERVIEW ..............................................................................................................
APPENDIX F - SILK - SC REEN ................................................................................. 18 APPEND IX G - COMPLIANCE NO TICES ............................................................. 19 F EDERAL C OMMUNICATIONS C OMMISSION S TATEMENT .
Introduction OMG - CONV - 485 - ISO Page 1 Introduction Overview The OMG - CONV - 485 - ISO is a single channel RS - 232 to RS - 422/485 asynchronous converter. It provides one field selectable RS-422/485 serial port supporting asynchronous data rates up to 115.
Card Setup OMG - CONV - 485 - ISO Page 2 Card Setup RS - 485 Enable Modes RS - 485 is ideal for multi - drop or network environments. RS - 485 requires a tri - state driver that will allow the electrical presence of the driver to be removed from the line.
Card Setup OMG - CONV - 485 - ISO Page 3 Communication Mode Examples (Dip switch SW1) ON 1 2 OFF Figure 1 - Dip switch SW1, RS - 422 ON 1 2 OFF Figure 2 – Dip switch SW1, RS - 485 ‘Auto’ Enable .
Card Setup OMG - CONV - 485 - ISO Page 4 Line Termination and Receiver Echo Off/On Typically, each end of the RS - 485 bus must have a line - terminating resistor (RS - 422 terminates at the receive end only).
Card Setup OMG - CONV - 485 - ISO Page 5 Electrical Interface Examples (Dip switch SW2) ON 1 2 OFF 3 4 5 6 Figure 6 – RS - 422 with Termination and Receiver Echo ON 1 2 OFF 3 4 5 6 Figure 7 – RS -.
Installation OMG - CONV - 485 - ISO Page 6 Operating System Installation (For Windows Users) RS - 422/RS - 485 Four Wire Master/RS - 485 Two Wire Auto Mode Installation If your application is 4 - wire.
Installation OMG - CONV - 485 - ISO Page 7 RS - 485 Two - Wire and RS - 485 Four - W ire Slave Installation If your application is 2 - wire Half - Duplex RS - 485 or 4 - Wire Full - Duplex RS - 485 Slave that requires control of the transmitter, the OMG - CONV - 485 - ISO provides 3 methods of control.
Installation OMG - CONV - 485 - ISO Page 8 Once the software installation is complete, the port must be configured for ‘ RTS Enable ’. This is accomplished by using the Device Manager in Windows 9X, ME, and Windows 2000. The port that the OMG - CONV - 485 - ISO is attached must be selected under Ports (COM & LPT) .
Installation OMG - CONV - 485 - ISO Page 9 System Installation The OMG - CONV - 485 - ISO can be connected to any existing RS - 232 port. A cable such as the CA - 177 can be used to attach the OMG - CONV - 485 - ISO DB - 25F to the PC’s DB - 9M connector.
Technical Description OMG - CONV - 485 - ISO Page 10 Technical Description The OMG - CONV - 485 - ISO converts an existing RS - 232 serial port into a field selectable RS - 422/485 port for industrial automation and control applications.
Specifications OMG - CONV - 485 - ISO Page 11 Specifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F) - 20º to 70º C (- 4º to 158º F) Humidity Range 10 to 90% R.H. Non - Condensing 10 to 90% R.
Appendix A - Troubleshooting OMG - CONV - 485 - ISO Page 12 Appendix A - Troubleshooting Serial Utility test software is supplied wit h the adapter and will be used in the troubleshooting procedures. By using this software and following these simple steps, most common problems can be eliminated without the need to call Technical Support.
Appendix B - How To Get Assistance OMG - CONV - 485 - ISO Page 13 Appendix B - How To Get Assistance Please refer to Appendix A - Troubleshooting prior to calling Technical Support. 1. Read this manual thoroughly before attempting to install the adapter in your system.
Appendix C – Electrical Interface OMG - CONV - 485 - ISO Page 14 Appendix C - Electrical Interface RS - 232 Quite possibly the most widely used communication standard is RS - 232. This implementation has been defined and revised several times and is often referred to as RS - 232 or EIA/TIA - 232.
Appendix C – Electrical Interface OMG - CONV - 485 - ISO Page 15 RS - 485 RS - 485 is backwardly compatible with RS - 422; however, it is optimized for partyline or multi - drop applications. The output of the RS - 422/485 driver is capable of being Active (enabled) or Tri - State (disabled).
Appendix D – Ground Loop Phenomenon OMG - CONV - 485 - ISO Page 16 Appendix D - Ground Loop Phenomenon What is Ground Loop? Ground loop Phenomenon occurs when two (or more) pieces of equipment are connected together with a common ground and a different ground potential exists at each location.
Appendix E - Asynchronous Communications OMG - CONV - 485 - ISO Page 17 Appendix E - Asynchronous Communicat ions Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character.
Appendix F - Silk - Screen OMG - CONV - 485 - ISO Page 18 Appendix F - Silk - Screen 2.688 in 2.078 in.
Appendix G - Compliance Notices OMG - CONV - 485 - ISO Page 19 Appendix G - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply with the limits for Class A digital device, pursua nt to Part 15 of the FCC Rules.
W ARRANTY / DISCLAIMER OME GA ENGINEERING, INC. war rants this unit to be free of defects in materials and workmanship for a period of 1 3 months from date of purc hase. OM E G A ’ s W ARRAN TY adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time.
M 3 88 8 /0303 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE Thermocouple, RTD & Thermistor Probes.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Omega Engineering OMG-CONV-485-ISO c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Omega Engineering OMG-CONV-485-ISO - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Omega Engineering OMG-CONV-485-ISO, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Omega Engineering OMG-CONV-485-ISO va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Omega Engineering OMG-CONV-485-ISO, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Omega Engineering OMG-CONV-485-ISO.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Omega Engineering OMG-CONV-485-ISO. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Omega Engineering OMG-CONV-485-ISO ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.