Manuel d'utilisation / d'entretien du produit AC-12100E du fabricant NewAir
Aller à la page of 17
AC-12100E PORT ABLE AIR CONDITIONER ’ OW NER S MANU AL.
1 CONTENT S The rating data indicated on the energy label is based on the testing condition of installing the un-extended air exhaust duct without adaptor A & B (The duct and the adaptor A & B are listed in the accessories chart of the Instruction Manual).
2 INTRODUCTION DISPOSAL: Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
3 To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. Your air conditioner should be used in such a way that it is protected from moisture.
4 Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille. Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important.
5 IDENTIFICATION OF P ART S NAMES OF P ARTS Fig.2 Front Operation Panel Horizontal Louver Blade (Swing automatically) Caster Carrying Handle (Both sides) 1 2 3 4 1 2 3 4 1 2 3 4 5 Model A Model B Operation Panel Horizontal Louver Blade (Manual) Remote signal receptor Caster Carrying Handle (Both) 1 2 3 4 5 Fig.
6 AIR CONDITIONER FEATURE S Before you begin , thoroughly familiarize yoursel f with the contro l panel and remot e controller and all it s functions, then follo w the symbol fo r the functions yo u desire. The unit ca n be controlled b y the unit contro l panel alone o r with the remot e controller .
7 OPERATING INSTRUCTION S 8 Operating Instr uctions - Press the "MODE" button until the "COOL" indicator light comes on. - Press the A DJUST buttons " " or " " to select your desired room temperature. The temperature can be set within a range of 62°F-88°F /17°C-30°C.
8 OPERATING INSTRUCTION S Other features In case of a power outage o r interruption, the unit will automatically re-start, in the settings last used, after the power is restored . Power Outage After the unit has stopped, operation cannot be restarted for the first 3 minutes after power has been restored.
9 INSTALL A TION INSTRUCTIONS (optiona l ) INSTALLA TION INSTRUCTIONS Locatio n Window Slider Kit Installa tion Fig.7 B A or bol t Window slider ki t bol t Window slider ki t or Vertical win d o w Window Slid er Kit Minimum : 1.84ft (56.2cm). Maximum:3.
1 0 INSTALL A TION INSTRUCTIONS (optional ) Installation in a double-hung sash window 1. Cut the foam seal (adhesive type) to the proper length and attach it to the window stool.
22.1 ~ 38.6 11 INSTALL A TION INSTRUCTIONS (optional ) Installation in a sliding sash window 1. Cut the foam seal (adhesive type) to the proper length and attach it to the window frame,Fig.
1 2 INSTALL A TION INSTRUCTIONS (optional ) Exhaust hose installation: The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. The duct ca n be compressed or extended moderately according to th e installation requirements, bu t it is desirable to kee p the duct lengt h to a minimum .
1 3 INSTALL A TION INSTRUCTION S Water drainage: - During dehumidifying modes, remove the drain plug from the back of the unit; install the drain connector (5/8 universal fem ale mender) with 3 4 hose (not included). For the models without drain connector , just attach the drain hose to the hole.
1 4 CARE AND MAINTENANC E CARE AND MAINTENANCE 1) Be sure to unplug the unit before cleaning or servicing. 2) Do not use gasoline, thinner or other chemicals to clean the unit. 3) Do not wash the unit directly under a tap or using a hose. It may cause electrical danger .
TROUBLESHOOTING TIP S TROUBLE SHOOTI NG 1. Unit does not start when pressing on/off button TROUBLES POSSIBLE CAUSES SUGGEST REMEDIES Reset the temperature. Make sure all the windows and doors are closed. Remove the heat sources if possible. Connect the duct and make sure it can function properly .
LIMITED MANUF ACTURER’S W ARRANTY This appliance is covered by a limited manufacturer ’s warranty . For one year from the original date of purchase, the manufacturer will repair or repl ace any pa.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté NewAir AC-12100E c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du NewAir AC-12100E - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation NewAir AC-12100E, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le NewAir AC-12100E va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le NewAir AC-12100E, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du NewAir AC-12100E.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le NewAir AC-12100E. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei NewAir AC-12100E ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.