New Buck Corporation Revised: November 2004 P.O. Box 69 8000 Hwy. 226 Sou th Spruce Pine, NC 28777 BUCK ST OVE MODEL 42ZCBB VENTLESS FIREBOX ENCLOSURE FOR GAS-FIRED DECORA TIVE TYPE UNVENTED ROOM HEA .
.
T ABLE OF CONTENTS Safety Information and Warnings ....................................................................................... 3 Installation .................................................................................................
2.
SAFETY INFORMA TION W ARNINGS IMPOR T ANT : READ THIS OWNER’S MANUAL CAREF ULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, INSTA LL, OPERATE, OR SERVICE THIS APPLIANCE (FIREBOX ENCLOSURE). Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
W ARNING DO NOT USE A BLOWER IN SER T , HEA T EXCHANGER INSER T , OR OTHER ACCESSO R Y NOT APPROVED FOR USE WITH THIS HEA TER. THIS HEA TER SHALL NOT BE INST ALLED IN A CONFINED SP ACE UNLESS PR OVISIONS ARE MADE FOR ADEQUA TE COMBUSTION AND VENTILA TION AIR.
INST ALLA TION Your New Buck Ventless Firebox Enclosure may be installed in Residentia l or *After-Market Manufactured Mobile Homes. This appliance may be installed in an *After Market Manufactured Mobile Home, where not prohibited by state or local codes.
FIREBOX AND FRAMING DIMENSIONS (ZC) & (FF) NOTE: SEE PAGE 10 IF AN OPTIONAL WOODEN FLUSH M OUNT MANTEL FRONT (FF) IS TO BE USED. Figure 2 GAS LINE 33-1/8" 18-15/16" 35-5/8" 36-5/8&q.
Figure 3 FIREBOX CLEARANCES The firebox may be placed dire ctly on a combustible floor, against a combustible wall at m arked clearances, or on a raised wooden platform. If the firebox is to b e installed on a raised woo den platform, the platform m ust be a continuous level surf ace.
FINISHING YOUR FIREBOX There is a wide variety of finishing material available for your firebox from formal wall treatments with m arble and mantels, to rustic wood paneling, stone or brick. IT IS IMPORTANT THAT THE BLACK FACE OF THE FIREBOX NOT BE COVERED WITH ANY TYPE OF COMBUSTIBLE MATE RIAL.
MANTEL PROFILES FOR VE NTLESS FIREBOX ENCLOSURE (UNIVERSAL BOX) ZERO CLEARANC E CABINET MUST BE FOLLOWED A 3” 3/4” 3 1/2” 4” B CANOPY STANDOFF COMBUSTIBLE MATERIALS 42ZCBB MANTEL CLEARANCES MANTEL WIDTH MANTEL HEIGHT (“ A ” inches ) (“ B ” inches above firebox op ening) 6.
D DATE REV. BY INST ALLA TION INSTRUC TIONS FOR MODEL 42ZCBB OPTIONAL WOODEN FLUSH MOUNT MANTEL FR ONT (FF) (KIT#P AKDM42ZCBBFF) “NOTE: Follow the framing instructions on page (s) 6 & 7. With the excep tion of the placement of the 42ZCBB in the framed opening .
INST ALLA TION I NSTRUCTI ONS FOR MODEL 42ZCBB OPTIONAL WOODEN SURROUND (WS) (KIT# P AKDM42ZCBB) CLEARANCES: 1. Sidewall Clearances: Clearances from the side of the firebox opening to any adjacent combustible wall should not be less than 7". See Figure 4 2.
REAR VIEW After assembling the WS you must insert the 42ZCBB. It is best to insert the 42ZCBB from the rear of the WS, this gives you more area to hold the 42ZCBB and reduces the risk of scratching the sur- face of the front area of the ba se (hearth) area.
This section is used for residential inst allation or mobile home installation. UNCONFINED SPACE: An unconfined space has a minimum air volume of 50 cubic feet for each 1,000 BTU/Hr (4.8m 3 per Kw) input rating of all appliances in the space (Cubic feet equals L ength x Width x Height of space).
3. Add the BTU/Hr of all fuel burning appliances in the space. Vent-Free Heater _________________________BTU/Hr. Gas Water Heater* _________________________BTU/Hr. Gas Furnace _________________________BTU/Hr. Vented Gas Heater _________________________BTU/Hr.
VENTILA TION AIR VENTILA TION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconf ined space. When venting to an adjoining space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see Options 1 and 2, Figure 6).
Figure 7 Ventilation Air From Outdoors W ARNING THIS HEATER MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT, POOR FUEL COMBUSTION COULD RESULT. READ THE FOLLOWING INSTRUCTIONS TO ENSURE PROPER FRESH AIR FOR THIS AND OTHER FUEL-BURNING APPLIANCES IN YOUR HOME.
OPTIONAL BLOWER INST ALLA TION The Model 42ZCBB has an optional MA ZCBB714 blower kit that can be purchased from your dealer. You will need to follow these steps and th e diagram below and the wiring diagram on page 15.
W ARNING: CHILDRE N AND ADULTS SHOU LD BE ALERTED OF HIGH SURFACE TEMPERATURE AND SHOULD STAT AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE. W ARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE APPLIANCE.
REPLACEMENT P AR TS 1. PULL SCREEN (2) PER UNIT 2. SCREEN RODS (2) PER UNIT 3. REAR REFRACT OR Y AND SIDE REFRACT OR Y 2 PIECES PER UNIT 6. CANOPY 7. DOOR KIT (P AR T# MAZCBBDOORS) P AR TS MA Y BE OBT AINED THROUGH YOUR LOCAL NBC DEALER. IN ABSENCE OF A DEALER, PLEASE CONT ACT NEW BUCK CORPORA TION A T P .
NEW BUCK CORPORA TION We reserve the right to amend th ese specifications at any tim e without notice. The only warranty applicable is our standard wr itten warranty.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté New Buck Corporation 42ZCBB c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du New Buck Corporation 42ZCBB - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation New Buck Corporation 42ZCBB, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le New Buck Corporation 42ZCBB va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le New Buck Corporation 42ZCBB, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du New Buck Corporation 42ZCBB.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le New Buck Corporation 42ZCBB. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei New Buck Corporation 42ZCBB ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.