Manuel d'utilisation / d'entretien du produit GVFS20P du fabricant Napoleon Fireplaces
Aller à la page of 16
1 W415-0559 / 02.15.06 W415-0559 / 02.07.06.
2 W415-0559 / 02.15.06 WHA T T O DO IF Y OU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier , call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone.
3 W415-0559 / 02.15.06 W ARNING • Under no cir cumstances should this heater be modified. • Pr ovide adequate v entila tion and combustion air . Pr ovide adequa te accessibility c learance f or servicing and oper ating the hea ter . Ne ver obstr uct the front opening of the heater .
4 W415-0559 / 02.15.06 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
5 W415-0559 / 02.15.06 FOR YOUR SA TISF ACTION, THIS FIREPLACE HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Maximum input is 23,000 BTU/hr for natural gas and propane.
6 W415-0559 / 02.15.06 MAINT AIN THESE MINIMUM CLEARANCES T O COMB USTIBLES: A. 4" B. 2" * C. 2" Pr ovide adequate v entilation and combustion air . Provide adequate accessibility clearance for servicing and operating the stove. Never obstruct the front opening of the stov e.
7 W415-0559 / 02.15.06 BL O WER INST ALLA TION GAS INST ALLA TION 1. Install rigid black pipe, or 1/2" type L copper tubing with a shut-off valve to the stove. 2. Seal and tighten the gas line securely to a fl ex connector . DO NOT KINK FLEXIBLE CONNECTOR.
8 W415-0559 / 02.15.06 FINISHING 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by remov- ing the screws from the brackets located in the upper inside corners.
9 W415-0559 / 02.15.06 3. Place the hole in the underside of log #3 onto the locating screw , on the right side of the burner . The bottom branch of log #3 sits infront of, and against, the right end of log #2.
10 W415-0559 / 02.15.06 • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour ’s phone. Follow the gas supplier ’s instructions. • If you cannot reach your gas supplier , call the fi re de- partment.
11 W415-0559 / 02.15.06 Air shutter adjustment must only be done by a qualifi ed gas installer! ADJUSTMENTS VENTURI ADJUSTMENT 1 . In order to properly clean the burner and pilot assembly , remove the logs exposing both assemblies.
12 W415-0559 / 02.15.06 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1.
13 W415-0559 / 02.15.06 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
14 W415-0559 / 02.15.06 Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
15 W415-0559 / 02.15.06 Pilot goes out while standing; Main burner is in ‘OFF’ position. Gas piping is undersized. - turn on all gas appliances and see if pilot fl ame fl utters, diminishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure.
16 W415-0559 / 02.15.06 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS NOTES.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon Fireplaces GVFS20P c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon Fireplaces GVFS20P - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon Fireplaces GVFS20P, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon Fireplaces GVFS20P va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon Fireplaces GVFS20P, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon Fireplaces GVFS20P.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon Fireplaces GVFS20P. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon Fireplaces GVFS20P ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.