Manuel d'utilisation / d'entretien du produit GD82PT-PA du fabricant Napoleon Fireplaces
Aller à la page of 32
1 W415-0665 / B / 02.1 1.08 INST ALLER: LEA VE THIS MANUAL WITH THE APPLIANCE CONSUMER: RET AIN THIS MANUAL FOR FUTURE REFERENCE CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS. Wolf Steel Ltd.
2 W415-0665 / B / 02.1 1.08 PG2-5 INTRODUCTION W arranty Fireplace Dimensions Installation Overview General Instructions General Information Care of Glass 6-11 VENTING V ent lengths V enting Specifi .
3 W415-0665 / B / 02.1 1.08 ® ® ® ® ® ® ® ® ® ® ® ®® ® ® ® ® The following materials and workmanship in your new NAPOLEON® gas fireplace are warranted against defects for as long as you own the fireplace.
4 W415-0665 / B / 02.1 1.08 FIGURE 1 22 1 / 8 " 21" 4" DIA. 7" DIA. 17 3 / 4 " 13 7 / 8 " 28" 14" 7 / 8 " 46" 58" 2" 8 7 / 8 " 28".
5 W415-0665 / B / 02.1 1.08 This gas fireplace should be installed and serviced by a qualified installer to conform with local codes. Installation practices vary from region to region and it is import.
6 W415-0665 / B / 02.1 1.08 VENTING For safe and proper operation of the fireplace follow the venting instruction exactly . Deviation from the minimum vertical vent length can create difficulty in burner start-up and/or carboning. Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed.
7 W415-0665 / B / 02.1 1.08 VER TICAL RISE IN FEET V T FIGURE 5 when (H T ) < (V T ) Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V T for the required horizontal run H T .
8 W415-0665 / B / 02.1 1.08 H 2 H 1 V 1 90° See graph to determine the required verti- cal rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .0 3 (t wo 90° elbows - 90°) = .03(180° - 90°) = 2.
9 W415-0665 / B / 02.1 1.08 REQUIRED VER TICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T when (H T ) < (V T ) FIGURE 10 For vent confi gurations requiring more than zero 90° e.
10 W415-0665 / B / 02.1 1.08 MAXIMUM VER TICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . Simple venting confi gurations See graph to determine the required vertical rise V T for the required horizontal run H T .
11 W415-0665 / B / 02.1 1.08 MINIMUM AIR TERMINAL L OCA TION CLEARANCES GD-301 FIGURE 14.
12 W415-0665 / B / 02.1 1.08 INST ALLA TION HORIZONT AL INST ALLA TION HORIZONT AL VENT SECTIONS: A minimum clearance of 2” all around the vent pipe on all horizontal runs to combustibles is required .
13 W415-0665 / B / 02.1 1.08 USING FLEXIBLE VENT COMPONENTS ELBOW SP ACERS ! W ARNING Note: Direct vent terminals shall not be recessed into a wall or siding. 1. Stretch the 4" diameter flexible vent pipe to the required length taking into account the additional length needed for the finished wall surface.
14 W415-0665 / B / 02.1 1.08 7. Ali gn i ng t h e seams o f t h e term i na l an d a i r term i na l connector , place the terminal over the air terminal connector making sure the liner goes into the hole in the terminal. Secure with the three screws provided.
15 W415-0665 / B / 02.1 1.08 MOBILE HOME INST ALLA TION This appliance is certified to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home or mobile home and m.
16 W415-0665 / B / 02.1 1.08 29” 72” MINIMUM ENCLOSURE HEIGHT Do not build into this area - it must be left clear to provide adequate clearance for the vent in this 14” wide area centered along the front of the fireplace. No combustibles are allowed.
17 W415-0665 / B / 02.1 1.08 Facing and/or fi nishing ma terial must nev er ov erhang into the fi replace opening. Do not distor t or force the frame kit components. W hen using a rough fi nish material (i.e.; stone), maintain a ¼” - ½” border fr om the framing components.
18 W415-0665 / B / 02.1 1.08 2” 2” 72” 26” 8” 56” MINIMUM PLUS RISE* COMBUSTIBLE NON-COMBUSTIBLE BRICK 1” COMBUSTIBLE NON- COMBUSTIBLE 0” IF NON- COMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE 12 1/4” INSULA TION SLEEVE 2” IMPORT ANT : The requires a minimum inside enclosure height of 72”.
19 W415-0665 / B / 02.1 1.08 OPTIONAL FRONT GLASS DOOR LA TCHES RET AINER Before the glass door can be removed, the optional front must be removed. The glass door is secured to the top front edge of the fi rebox with two latches.
20 W415-0665 / B / 02.1 1.08 1. Attach screw and spacer as illustrated in (Fig. 44) to the bottom of both sides of the front housing. 2. Attach the face plate bracket provided to the top edge of the front housing using 2 #8 - 1/2” truss head screws as illustrated in (Fig.
21 W415-0665 / B / 02.1 1.08 SER VICING / REPLACEMENTS 1a. Rectangular Front Removal Pull on the top of the optional front away from the fi replace until the male portion of the latch disengages. T ilt forward slightly and lift from the 2 shoulder screws near the bottom.
22 W415-0665 / B / 02.1 1.08 Yo u r comes equipped with our “Night Light™”. The light has been pre-wired and is controlled from the remote control. If in the event the lamp or lens needs to be replaced, follow the instructions below . Unplug the wire harness / transformer from the FCM (Fan Control Module) inside the fi replace.
23 W415-0665 / B / 02.1 1.08 The Smart Thermostat function adjusts the fl ame height according to the difference between the set temperature and the actual room temperatures. As the room temperature gets closer to the set point the Smart Function will automatically adjust the fl ame down.
24 W415-0665 / B / 02.1 1.08 F AN SPEED CHILD PROOF FUNCTION If the appliance is equipped with a hot air circulating fan, the speed of the fan can be controlled by the remote system. The fan speed can be adjusted through six (6) speeds. 1. Use the Mode key to guide you to the fan control icon.
25 W415-0665 / B / 02.1 1.08 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor .
26 W415-0665 / B / 02.1 1.08 FIGURE 76 Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow . FIGURE 77 PILO T B URNER ADJUSTMENT TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE.
27 W415-0665 / B / 02.1 1.08 ** W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
28 W415-0665 / B / 02.1 1.08 40 40 54 53 52 19 9 22 20 10 18 21 32 60 61 66 26 24 25 27 35 2 13 11 * * 15 14 12 63 46 47 48 7 1 3 4 49 64 5 6.
29 W415-0665 / B / 02.1 1.08 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- - clean the glass with a gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become per- manently marked.
30 W415-0665 / B / 02.1 1.08 Remote wall switch is in “OFF” position; main burner comes on when gas knob is turned to “ON” position. W all switch is mounted up- side down - reverse. Faulty valve. - replace. - replace. Remote wall switch is ground- ing.
31 W415-0665 / B / 02.1 1.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS.
32 W415-0665 / B / 02.1 1.08 NOTES.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon Fireplaces GD82PT-PA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon Fireplaces GD82PT-PA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon Fireplaces GD82PT-PA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon Fireplaces GD82PT-PA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon Fireplaces GD82PT-PA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon Fireplaces GD82PT-PA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon Fireplaces GD82PT-PA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon Fireplaces GD82PT-PA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.