Manuel d'utilisation / d'entretien du produit BGD42P du fabricant Napoleon Fireplaces
Aller à la page of 28
1 W415-0381 / E / 02.09.06 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0381 / E / 02.09.06 WARNING • Do not burn wood or other ma terials in this f ir eplace . • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
3 W415-0381 / E / 02.09.06 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915.
4 W415-0381 / E / 02.09.06 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERV - ICED BY A QUALIFIED INST ALLER to conform with local codes. In absence of local codes, install the BG D42 to the current Na- tional Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
5 W415-0381 / E / 02.09.06 Use only Wolf S teel, Simp son Dura-V ent, Selkirk Direct Temp or American Metal Amerivent venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for ei- ther system are set out in this manual and must be ad- hered to.
6 W415-0381 / E / 02.09.06 * Recommended to prevent condensation on windows and thermal breakage ** Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of 18". It is recommended to maximize the distance to vinyl clad soffits.
7 W415-0381 / E / 02.09.06 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated.
8 W415-0381 / E / 02.09.06 VERTI C AL TERMINA TION HORIZONT AL TERMINA TION vertical rise is equal to or greater than the horizontal run horizontal run + verti- cal rise to maximum of 40 feet vertical.
9 W415-0381 / E / 02.09.06 ELBO W VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMINA TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 .
10 W415-0381 / E / 02.09.06 V 1 HORIZONT AL TERMIN A TION See graph to determine the re- quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.
11 W415-0381 / E / 02.09.06 90° 90° V 1 H 1 H 2 V 2 45° 90° 45° VERTICAL TERMIN A TION Example 3: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =3 f t H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .
12 W415-0381 / E / 02.09.06 H 1 VERTICAL TERMIN A TION For vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H.
13 W415-0381 / E / 02.09.06 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napo- leon dealer .
14 W415-0381 / E / 02.09.06 AIR TERMINAL CONNECTOR INNER FLEX LINER OUTER FLEX LINER INNER SLEEVE HIGH TEMPERA TURE SEALANT ROOF SUPPORT FIGURE 18 A VENT SHIELD MUST BE USED IF THE W ALL TERMINAL IS INST ALLED ON COMBUSTIBLE, EXTERIOR SURF ACES. 1. Cut or frame a hole in an exterior wall with a minimum round or square opening of 10½ inches.
15 W415-0381 / E / 02.09.06 STORM COLLAR FLASHING CAULKING WEATHE R SEALA NT 2” AIR INL ET BASE FIGURE 25 The vent system must be supported approximately every 3 feet for both vertical and horizontal runs.
16 W415-0381 / E / 02.09.06 V ertical terminations may display a very active flame. As this appearance is not desirable, the vent exit must be restricted using restrictor plate, W500-0205. This reduces the velocity of the exhaust gases, slowing down the flame pattern and creating a more traditional appearance.
17 W415-0381 / E / 02.09.06 TO INST ALL THE UPPER L OUVRES: Insert the upper louvres into the slots on both brackets. TO INST ALL THE L OWER L OUVRE ASSEMBL Y: At- tach each hinge to the fire- bo x with 2 screws. Position the hinge screen into place and with the con- trol door open, secure to the firebox using three screws.
18 W415-0381 / E / 02.09.06 NAILING TA B 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts.
19 W415-0381 / E / 02.09.06 PHAZER TM logs and glowing embers, exclusive to Napo- leon Fireplaces, provide a unique and realistic glowing ef- fect that is different in every inst allation. T ake the time to carefully position the glowing embers for a maximum glow- ing effect.
20 W415-0381 / E / 02.09.06 the log resting in the pocket of the left crossover log. 5. Place the bottom of the right crossover log (#6) against the right side of the grate. Place the top into the pocket provided on the center log (#5). Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner .
21 W415-0381 / E / 02.09.06 against the threaded stud (B) at the other end. The blower must be able to be po- sitioned entirely onto the pad. Tilt the blower onto its side. Slide it past the controls and into the clip (C) . Secure to the threaded stud using the lock washer and wing nut provided.
22 W415-0381 / E / 02.09.06 Position the vibration reducing pad into the clip and onto the threaded stud at the other end, piercing a hole into the pad. The fan assembly must be able to be positioned en- tirely onto the pad. Slide the fan assembly past the controls and into the clip.
23 W415-0381 / E / 02.09.06 slightly . 1. S top! Read the above safety information on this label. 2. Turn off all electric power to the fireplace. 3. Turn the gas knob clockwise to off. 4. Wait five (5) minutes to clear out any gas. If you smell gas including near the floor .
24 W415-0381 / E / 02.09.06 Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.- Adjustment may be required depending on fuel type, vent configuration and altitude. Closing the air shutter will cause a more yellow flame, but can lead to carboning.
25 W415-0381 / E / 02.09.06 1 7 W135-0203 RIGHT CROSSOVER LOG (#6) 1 8 W135-0199 SMALL LEFT LOG (#2) 1 9 W135-0200 SMALL RIGHT LOG (#3) 2 0 W010-0770 BLACK DOOR C / W GLASS 2 1 W455-0026 #38 NATURAL G.
26 W415-0381 / E / 02.09.06.
27 W415-0381 / E / 02.09.06 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
28 W415-0381 / E / 02.09.06 Pilot goes out while standing; Main burner is in 'OFF' position. Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, dimin- ishes or extinguishes, especially when main burner ignites.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon Fireplaces BGD42P c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon Fireplaces BGD42P - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon Fireplaces BGD42P, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon Fireplaces BGD42P va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon Fireplaces BGD42P, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon Fireplaces BGD42P.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon Fireplaces BGD42P. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon Fireplaces BGD42P ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.