1 W415-0377 / 03.04.03 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.
2 W415-0377 / 03.04.03 P G 2 - 4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5 VENTING V ent Safety Switch Hi Limit Switch V enting Action Check 6 -.
3 W415-0377 / 03.04.03 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0377 / 03.04.03 Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The fireplace is factory equipped with 3/16" thick tempered glass. Use only re- placement glass available from your Napoleon dealer . Do not substitute ma terials .
5 W415-0377 / 03.04.03 This is a vented appliance and must be connected to a chimney in accordance with the current installation codes. In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
6 W415-0377 / 03.04.03 It is best to frame your fireplace after it is positioned. Use 2x4's and frame to local building codes. FIGURE 7-9. Note: In order to avoid the possibility of exposed insul.
7 W415-0377 / 03.04.03 NAILING TA B 1) Attach the nailing tabs to the corner post s using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts.
8 W415-0377 / 03.04.03 The upper louvres must be removed to allow the door to be removed. Release the two door latches, located across the top of the door and lift off the lower door bracket. Insert the upper louvres into the slots on both brackets. Attach each hinge on the lower louvre assembly to the lip of the fireplace base with 2 screws.
9 W415-0377 / 03.04.03 PHAZER TM logs and glowing embers, exclusive to Napo- leon Fireplaces, provide a unique and realistic glowing ef- fect that is different in every inst allation. T ake the time to carefully position the glowing embers for a maximum glow- ing effect.
10 W415-0377 / 03.04.03 Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the secur- ing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.
11 W415-0377 / 03.04.03 Attach and secure the sensor assembly bracket to the se- curing stud located next to the receptacle/junction box at the bottom left of the unit using the lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.
12 W415-0377 / 03.04.03 • Turn off all gas to the fireplace. • Open windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone.
13 W415-0377 / 03.04.03 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
14 W415-0377 / 03.04.03 # P ART N o . DESCRIPTION 2 5 GDL42K LOUVRE KIT - UPPER & LOWER - BLACK 2 5 GDL42PB LOUVRE KIT - UPPER & LOWER - POLISHED BRASS 2 5 GDL42SS LOUVRE KIT - UPPER & LOW.
15 W415-0377 / 03.04.03 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
16 W415-0377 / 03.04.03 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fireplace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become permanently marked.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon BGNV42N c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon BGNV42N - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon BGNV42N, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon BGNV42N va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon BGNV42N, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon BGNV42N.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon BGNV42N. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon BGNV42N ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.