Manuel d'utilisation / d'entretien du produit BGD42 du fabricant Napoleon
Aller à la page of 28
1 W415-0381 / H / 12.07.07 W415-0381 / H / 12.07.07 $10.00.
2 W415-0381 / H / 12.07.07 20-22 FINISHING Door , Louvre & Panel Removal & Installation Grate Installation Log Placement / Glowing Embers V ermiculite Charcoal Embers Charcoal Lumps 22 OPTIONA.
3 W415-0381 / H / 12.07.07 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0381 / H / 12.07.07 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the BGD42 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
5 W415-0381 / H / 12.07.07 FIGURE 1 INST ALLA TION O VERVIEW FIGURE 2.
6 W415-0381 / H / 12.07.07 A terminal shall not terminate dir ectly abov e a sidewalk or pav ed drivew ay which is loca ted between two single f amily dwellings and serves both dw ellings . Local codes or regula tions may requir e dif fer ent clearances .
7 W415-0381 / H / 12.07.07 MINIMUM AIR TERMINAL L OCA TION CLEARANCES 32 32 32 32 32 32 4 Using a soffit heat shield (W585-0096), or equivalent, the distance may be reduced to a minimum of 18”. It is recommended to maximize the distance to the vinyl clad soffits.
8 W415-0381 / H / 12.07.07 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum of 12" above grade.
9 W415-0381 / H / 12.07.07 VER TICAL TERMINA TION HORIZONT AL TERMINA TION vertical rise is equal to or greater than the horizontal run horizontal run + v erti- cal rise to maximum of 40 feet vertical.
10 W415-0381 / H / 12.07.07 ELBOW VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMIN A TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE6 .
11 W415-0381 / H / 12.07.07 V 1 HORIZONT AL TERMIN A TION See graph to determine the re- quired vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.
12 W415-0381 / H / 12.07.07 90° 90° V 1 H 1 H 2 V 2 45° 90° 45° VERTICAL TERMIN A TION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .
13 W415-0381 / H / 12.07.07 H 1 VERTICAL TERMIN A TION For vent confi gurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2:.
14 W415-0381 / H / 12.07.07 1. Determine the air terminal location, cut and frame 10 3/4" square openings in the ceiling and the roof to provide the minimum 1" clear- ance between the vent pipe and any combustible material. T ry to center the vent pipe location midway between two joist to prevent having to cut them.
15 W415-0381 / H / 12.07.07 DO NOT CLAMP THE FLEXIBLE LINER FIGURE 24b 1. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an al- ternate method suitable to the authority having jurisdiction or the optional roof support.
16 W415-0381 / H / 12.07.07 FIGURE 25 5. Remove nails from the shingles, above and to the sides of the chimney . Place the fl ashing over the air terminal connector leaving a min. 3/4” of the air terminal connector showing above the top of the fl ashing.
17 W415-0381 / H / 12.07.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. FIGURE 21. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
18 W415-0381 / H / 12.07.07 FIGURE 33 This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. The fi replace is equippe d with two 1/4" diameter holes located in the front left and right corners of the base.
19 W415-0381 / H / 12.07.07 FIGURE 34 FIGURES 36a-c TOP SLOT FINISHING MA TERIAL CORNER POST NAILING TA B A B C CENTRE HOLE NAILING TA B 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied.
20 W415-0381 / H / 12.07.07 MINIMUM MANTEL AND ENCLOSURE CLEARANCES FIGURES 37a FIGURES 37b Combustible mantel clearance can vary according to the mantel depth.
21 W415-0381 / H / 12.07.07 Remove the backing of the logo supplied and place on the glass view- ing door , as indicated. FIGURE 40 LOG O ½" ½" LOGO PLA CEMENT PORCELAIN REFLECTIVE P ANELS 1. Remove the upper louvres, and open the glass door .
22 W415-0381 / H / 12.07.07 FIGURE 44 FIGURE 48 FIGURE 49 FIGURE 45 FIGURE 50 INST ALLA TION T O BE DONE BY A QUALIFIED INST ALLER and must be electrically con- nected and grounded in ac- cordance with local codes. In the absence of local codes, use the current CSA C22.
23 W415-0381 / H / 12.07.07 Unplug the power cord from the receptacle. Connect all wires as shown. Attach and secure the sen- sor assembly bracket to the securing stud located next to the receptacle/ junction box at the bottom left of the unit using the lock washer and wing nut.
24 W415-0381 / H / 12.07.07 FIGURE 57 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports.
25 W415-0381 / H / 12.07.07 # P ART NO. DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE** 4 W010-0800 NA TURAL GAS PILOT ASSEMBL Y 4 W010-0801 PROP ANE GAS PILOT .
26 W415-0381 / H / 12.07.07.
27 W415-0381 / H / 12.07.07 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button igniter . - check if the push button igniter needs tightening. - replace the wire if the wire insulation is broken or frayed.
28 W415-0381 / H / 12.07.07 White / grey film forms. Sulphur from fuel is being depos- ited on glass, logs or combustion chamber surfaces. - clean the glass with a recommended gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become permanently marked.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon BGD42 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon BGD42 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon BGD42, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon BGD42 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon BGD42, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon BGD42.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon BGD42. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon BGD42 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.