Manuel d'utilisation / d'entretien du produit BGD40-N du fabricant Napoleon
Aller à la page of 36
1 W415-0299 / C / 03.12.03 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0299 / C / 03.12.03 Pg 3- 5 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts Dimensions 6 -13 VENTING V ent Lengths Air T erminal Installation V e.
3 W415-0299 / C / 03.12.03 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0299 / C / 03.12.03 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to re- gion and it is imp.
5 W415-0299 / C / 03.12.03 V ent lengths that pass thr ough unheated spaces (a t- tics, garages, crawl spaces) should be insulated with the insulation wrapped in a protective sleeve to minimize condensation. Objects placed in front of the fireplace must be kept a minimum of 48" away from the glass front faces of the unit.
6 W415-0299 / C / 03.12.03 Use only Wolf S teel or Simpson Dura-V ent Model DV -GS venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air termi- nal locations for either system are set out in this manual and must be adhered to.
7 W415-0299 / C / 03.12.03 AIR TERMINAL INST ALLA TIONS * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * I t i s re c o m m en d e d t o u s e a he a t s h i e l d a n d t o m a x im i z e t h e d i s ta n c e t o v i n yl cl a d s o f f it s.
8 W415-0299 / C / 03.12.03 VENTING APPLICA TION FLO WCHART VER VER VER VER VER TICAL TICAL TICAL TICAL TICAL TERMIN TERMIN TERMIN TERMIN TERMIN A A A A A TION TION TION TION TION HORIZONT HORIZONT HOR.
9 W415-0299 / C / 03.12.03 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the model of fireplace, as illustrated.
10 W415-0299 / C / 03.12.03 REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) Simple ventin.
11 W415-0299 / C / 03.12.03 See graph to determine the re- quired vertical rise V T for the required horizontal run H T . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.
12 W415-0299 / C / 03.12.03 Example 3: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =3 f t H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.
13 W415-0299 / C / 03.12.03 For vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 feet Examp.
14 W415-0299 / C / 03.12.03 When finishing the fireplace, combustible material may rest directly on of the top extension. In order to achieve a countertop or bar type appearance with the minimum heigh.
15 W415-0299 / C / 03.12.03 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
16 W415-0299 / C / 03.12.03 Refer to pages 6-13. All venting must have a minimum clearance of 1" to combustible. See Page 18 for additional framing dimensions.
17 W415-0299 / C / 03.12.03 Refer to pages 6-13. All venting must have a minimum clearance of 1" to combustible. See Page 18 for additional framing dimensions.
18 W415-0299 / C / 03.12.03 There must be a minimum of 1" clearance to combustibles when framing around all venting options. See pages 14-17. FIGURE 26 FIGURE 27 Horizontal Vent Off Fireplace Vertical Vent Off Fireplace A = 42" using flexible vent components.
19 W415-0299 / C / 03.12.03 For optimum performance it is recommended that all horizontal runs have a minimum 1 inch rise per foot us- ing flexible venting. For safe and proper operation of the fireplace, follow the venting instr uctions exactly . This application occurs when venting through an exterior wall.
20 W415-0299 / C / 03.12.03 F or safe and proper operation of the fireplace, follow the venting instr uctions e xactly . 1. Stretch the 5" diameter aluminum flexible liner to the required length taking into account the additional length needed for the finished wall surface.
21 W415-0299 / C / 03.12.03 FIGURE 40 FIGURE 39 1. Move the fireplace into position. 2. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the vent- ing is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
22 W415-0299 / C / 03.12.03 Do not connect either the wall switch, thermostat or gas valve to electricity (110 volts). Attach the two leads to terminals 1 and 3 located on the gas valve.
23 W415-0299 / C / 03.12.03 PHAZER TM logs, glowing and charcoal embers, exclusive to Napoleon fireplaces, provide a unique and realistic glow- ing effect that is dif ferent in every installation. T ake the time to carefully position the embers for a maximum glowing effect.
24 W415-0299 / C / 03.12.03 FIGURE 50 Attach the hood with louvre brackets by pressing the top flange of the bracket into the clips along the top of the louvre opening with louvre securing tabs facing out. Using 6 screws, attach the lower louvre brackets and hinge screen as illustrated.
25 W415-0299 / C / 03.12.03 Ensure that the door is properly clipped onto the steel lip to pre- vent overheat- ing, glass break- age and / or dis- colouration of the upper trim. To install the door(s), hook it over the steel lip located above the door opening.
26 W415-0299 / C / 03.12.03 Remove the "Z" shaped mounting bracket secured to the burner , by the pilot. Remove the thermodisc from the bracket supplied in the blower kit and attach to the mounting bracket. Attach the connectors from the black and white wires to the thermodisc.
27 W415-0299 / C / 03.12.03 • Turn off all gas to the fireplace. • O pen windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • I mmediately call your gas supplier from a neighbour's phone.
28 W415-0299 / C / 03.12.03 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Natural gas models have air shutters set at 1/4 (.250") inch open. Propane gas models have air shutters set at 7/16 (.
29 W415-0299 / C / 03.12.03 # P ART N o. DESCRIPTION 1* W361-0016 GLOWING EMBERS 2* W550-0001 CHARCOAL EMBERS 3 W562-0009 DOOR GASKET (100 INCHES) 4 W010-0454 GLASS W/ GASKET 5* W500-0028 FIRESTOP - F.
30 W415-0299 / C / 03.12.03 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd.
31 W415-0299 / C / 03.12.03 # P ART N o. DESCRIPTION 1 W690-0001 MILLIVOL T THERMOST A T 2 GD501 HE A T GUARD 3* W573-0008 HI-TEMP SEALANT 4* W010-0370 WALL SUPPORT ASSEMBL Y 5 GZ-550-1KT BLOWER KIT 6.
32 W415-0299 / C / 03.12.03 Carbon is being deposited on glass, logs or combustion chamber sur- faces. Flame is impinging on the logs or combustion cham- ber . - check that the logs are correctly positioned. - open air shutter to increase the primary air .
33 W415-0299 / C / 03.12.03 Main burner goes out; pilot goes out. Refer to " MAIN B URNER GOES OUT ; PIL OT ST A YS ON " V ent is blocked - check for vent blockage. - check joint seals and installation. 5" flexible vent has become disconnected from fireplace.
34 W415-0299 / C / 03.12.03 Wolf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer.
35 W415-0299 / C / 03.12.03 NO TES.
36 W415-0299 / C / 03.12.03 NO TES.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon BGD40-N c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon BGD40-N - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon BGD40-N, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon BGD40-N va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon BGD40-N, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon BGD40-N.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon BGD40-N. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon BGD40-N ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.