Manuel d'utilisation / d'entretien du produit Allergy cylinder vacuum cleaner du fabricant Morphy Richards
Aller à la page of 12
getting the best from your new cleaner ... If your cleaner isn’t picking up as well as it should, please check • Dustbags It is important to replace them, otherwise the performance of the cleaner .
2 Impor tant safety instructions The use of any electrical appliance r equir es the following common sense safety rules. Primarily there is danger of injury or death and secondly the danger of damage to the appliance.
3 F eatur es ⁄ › ¤ ‹ ‚ Ê „ Ï ‰ · Ô Ò Î Ë È Ó Ì ⁄ Dust compartment cover ¤ Opening for suction hose ‹ Dust compartment lock button › T ool storage compartment cover .
Standard accessories Application Curtains and delicate fabrics T extiles and upholstery Shelves and hard surfaces Carpets and other textile floor coverings (brushes up) Settings for heavy dirt and smo.
5 Power setting Application Curtains and delicate fabrics T extiles and upholstery Floor coverings such as rugs or economy setting for carpets Carpets or hard floor coverings Open Closed Controlling suction power The suction power can be varied to suit the surface being cleaned, by using the variable power control.
6 T ube standby During short breaks in cleaning the tubes can be held in an upright, ‘standby’ position, whilst you move furniture for instance. IMPORT ANT : Ensure that the appliance is never left unattended whilst it is switched on. Switching of f Switch off the appliance.
7 Changing the dustbag If suction power is reduced or if the ‘dust bag full’ indicator is permanently on, the dust bag needs changing. Also check whether the suction hose, tube or nozzle are blocked. To access the dust bag, pr ess the dust compartment release button to open the cover .
8 Changing the mot or pr otection filt er IMPORT ANT : Never use the appliance without the motor protection filter installed, otherwise damage to the motor may occur which would not be covered by the guarantee.
Changing the exhaust air filt er The exhaust air filter should be cleaned by shaking every time the dustbag is changed. This filter can also be washed in warm water (no detergents added) and allowed to dry naturally . IMPORT ANT : The filter must be totally dry before putting it back into the cleaner .
10 The British Allergy Foundation considers that these pr oducts may , in proper use, r educe exposure to both House Dust Mite (Der p 1) and Cat Aller gen (Fel d 1). Assessment carried out by BAF indicate that an individuals exposure can be r educed but this does not mean that an individuals allergic symptoms will necessarily diminish.
11 Y our thr ee-year guarant ee • It is important to retain the r etailers re ceipt as proof of purchase. Staple your receipt to this back cover for futur e r efer ence. Please quote the following information if the product develops a fault. These numbers can be found on the base of the product.
VC70047M UK Rev 1 02/05 The After Sales Division, Morphy Richards Ltd, Mexbor ough, South Y orkshire, England, S64 8AJ Helpline (office hours) UK 0870 0602604 Republic of Ireland 1800 409119 Morphy Richards pr oducts are intended for household use only Morphy Richards has a policy of continuous improvement in pr oduct quality and design.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Morphy Richards Allergy cylinder vacuum cleaner c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Morphy Richards Allergy cylinder vacuum cleaner - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Morphy Richards Allergy cylinder vacuum cleaner, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Morphy Richards Allergy cylinder vacuum cleaner va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Morphy Richards Allergy cylinder vacuum cleaner, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Morphy Richards Allergy cylinder vacuum cleaner.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Morphy Richards Allergy cylinder vacuum cleaner. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Morphy Richards Allergy cylinder vacuum cleaner ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.