MODELS: BBV400 SBV400 SBV500 B-VENT SERIES NA TURAL VENT GAS FIREPLACE W ARNINGS IF THE INF OR MA TI ON I N TH ESE INS TR UCT ION S AR E NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE.
2 62D4036 CONTENTS Important Safety Information .......................... 3 Product Features .............................................. 5 Code Approval .................................................. 5 Pre-Installation Information Installing Above 2000 Feet .
62D4036 3 4. Never install the fireplace • in a recreational vehicle • whe re cur tain s, fur nitu re, cl othi ng, or ot her flam mab le objects are less than 42" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5.
4 62D4036 IMPORT ANT SAFETY INFORMA TION Continued fr om page 3 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Never place anything on top of fireplace. 14. Do not use any solid fuels (wood, coal, paper , cardb oard, etc.
62D4036 5 PRODUCT FEA TURES AND CODE APPROV AL Figure 1 - BBV/SBV Fireplace • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. • The appliance must be installed in accordance with local codes if any .
6 62D4036 PRE-INST ALLA TION INFORMA TION INST ALLING ABOVE 2000 FEET • In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations. • In Canada, these appliances are certified for altitudes of 0 – 2000 ft, and must be de-rated by 10 percent for installations between 2000 and 4,500 ft.
62D4036 7 B A H G D F E A C 1 / 2 " or 5 / 8 " C A G C G A PRE-INST ALLA TION INFORMA TION FIREPLACE FRAMING Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figur e 2 and the chart below for your specific installation requirements.
8 62D4036 31 3 / 8 " 4 " B-V ent 6 " 34 " 1 / 2 " or 5 / 8 " Drywall Spacers 14 " 8 " 21 1 / 2 " 9 5 / 8 " Air Kit 2 3 / 16 " 1 / 2 " or 5 /.
62D4036 9 A 6 " B-V ent 6 " 34 " 1 / 2 " or 5 / 8 " Drywall Spacers 21 " 13 7 / 16 " 21 1 / 2 " 16 3 / 4 " 9 5 / 8 " Air Kit 1 / 2 " or 5 / 8 &qu.
10 62D4036 PRE-INST ALLA TION INFORMA TION FIREPLACE LOCA TION Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.
62D4036 1 1 12" Maximum Depth 8" Minimum 72" Minimum Minimum 3" From Both Side W alls to Opening Follow these instructions carefully to ensure safe installation.
12 62D4036 The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6 . Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor .
62D4036 13 Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury , property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury , property damage or loss of life.
14 62D4036 B-VENT PIPE SIZING BBV400/400BBV SBV400/400SBV SBV500/500SBV 4" 6" 6" VENT INST ALLA TION INST ALLA TION PLANNING “B” VENT PIPE See venting installation instructions provided by the B-V ent manufacturer .
62D4036 15 T reatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitutes for the requirements of local building codes.
16 62D4036 8' Maximum OUTSIDE COMBUSTION AIR PRECAUTIONS AND RECOMMENDA TIONS No te : T he us e o f o ut sid e air fo r c om bus ti on is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of fireplace.
62D4036 17 COMBUSTION AIR ASSEMBL Y MODEL OAC-4 COMBUSTION AIR ASSEMBL Y 1. Remove the cover plate from the 4" outlet opening location on the left outside of the fireplace. 2. Place starting collar (4") into hole on left side of fireplace.
18 62D4036 Figure 16 - External Regulator with V ent Pointing Down (Propane/LP Only) Use only new black iron or steel pipe. Internally tinned copper or copper tubing can be used per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfide limits, and where permitted by local codes.
62D4036 19 3 " M i ni m um FIREPLACE INST ALLA TION A listed manual shutof f valve must be installed upstream of the appliance. Union tee and plugged 1 / 8 " NPT pressure tapping point should be installed upstream of the appliance. See Figur e 17.
20 62D4036 CHECKING GAS PRESSURE 1. Check gas type. The gas supply must be the same as stated on the applianceʼ s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately . 2.
62D4036 21 ON OFF OPTIONAL REMOTE W ALL SWITCH ON OFF OPTIONAL REMOTE W ALL SWITCH PILOT HI LO ON OFF TH TP TH/TP ON OFF SPILL SWITCH RS REMOTE W ALL MOUNTED SWITCH A remo te wall switch and up to fiftee n (15) feet of 18 Ga. wire may be used with this applia nce.
22 62D4036 ELECTRICAL INST ALLA TION ELECTRONIC PILOT IGNITION WIRING Do not connect 1 10-120 V AC to the Remote W all Switch. The appliance will malfunction or destroyed. W ARNING REMOTE W ALL SWITCH Position the wall switch. Do not extend beyond the 15' of wire.
62D4036 23 Flat Area FINAL INST ALLA TION LOG PLACEMENT 1. Place rear log (#1) on grate assembly . Log should rest firmly on the two log mounting pins on the horizontal bars. See Figur e 22. 2. Place top right log (#2) on the rear log. Rest the right back side of the log in the flat area of the rear log.
24 62D4036 A. This appliance is equipped with a pilot which must be lit with an ignitor while following these instructions exactly . B. BEFORE OPERA TING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor .
62D4036 25 P I L O T O F F P I L O T O N Continued on next page OPERA TING INSTRUCTIONS APPROVED LEAK TESTING METHOD Y ou may check for gas leaks with the following methods only: • Soap and water so.
26 62D4036 50 P I L O T O F F P I L O T O N O F F P I L O T O N P I L O T Figure 25 - On Position P I L O T O F F P I L O T O N Figure 24 - On/Off/RS Switch OPERA TING INSTRUCTIONS L IG HT IN G B UR N E R MAIN BURNER SWITCH The “ON/OFF” switch for the main burner can be found behind door of the fire - place.
62D4036 27 ON OFF PILO T LO HI Figure 28 - Electronic Gas V alve OPERA TING INSTRUCTIONS LIGHTING ELECTRONIC IGN 1. STOP! Read the safety information above. 2. Set thermostat to lowest setting. Then turn switch to of f posi - tion. 3. T urn off all electric power to the appliance.
28 62D4036 Figure 29 - Pilot Flame Thermopile Thermocouple T urn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of.
62D4036 29 CLEANING AND MAINTENANCE VENT SYSTEM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow .
30 62D4036 1 2 3 4a 4b 4c 5 7 6 ILLUSTRA TED P ARTS LISTS FIREBOX COMPONENTS.
62D4036 31 FIREBOX COMPONENTS ILLUSTRA TED P ARTS LISTS Item Description Qty BBV400/400BBV SBV400/400SBV SBV500/500SBV 1 Pull Screen Panel 2 61D0001 61D0001 61D0003 2 Refractory Side 2 n/a 61D0101 61D.
32 62D4036 ILLUSTRA TED P ARTS LISTS 1 2 3 4 5 6 7 8 10 12, 13 ST ANDING PILOT — MILLIVOL T CONTROL 2T 2 I 2C 9 1 1.
62D4036 33 ILLUSTRA TED P ARTS LISTS ST ANDING PILOT – MILLIVOL T CONTROL Item Description Qty BBV400NV BBV400PV SBV400NV SBV400PV SBV500NV SBV500PV 1 Gas V alve Assembly 1 37D01 17 37D01 18 37D01 1.
34 62D4036 ILLUSTRA TED P ARTS LISTS 1 2 3 4 5 6 7 9 ELECTRONIC IGNITION 8 10 1 1 12.
62D4036 35 ELECTRONIC IGNITION ILLUSTRA TED P ARTS LISTS It em Description Qty BBV400NV BBV400PV SBV400NV SBV400PV SBV500NV SBV500PV 1 Gas V alve Assembly 1 37D0016 37D0017 37D0016 37D0017 37D0016 37D.
36 62D4036 ST ANDING PILOT IGNITION TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE ACTION 1. Spark ignitor will not light pilot after repeated trig- gering of piezo. A. W ire disconnected. B. Defective ignitor . C. No gas or low gas pressure. D. No Propane/LPG in tank A.
62D4036 37 ELECTRONIC IGNITION TROUBLESHOOTING ST ART 1. Turn gas supply of f. 2. Turn ON/OFF switch to “ON” Power to module (24V Normal) YES Is there a spark across ignitor sensor gap? YES T urn on gas.
38 62D4036 TROUBLESHOOTING GENERAL TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE ACTION 1. Glass Soots A. Flame impingement on logs A. Install log set per instructions. Inspect the injector and air intake area. Make sure this area does not have any blockage from debris and clean.
NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fi tter when installed within the Commonwealth of Massachusetts.
SPECIAL REQUIREMENTS CONTINUED 2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accor- dance with the above provisions shall comply with NFP A 720 and be ANSI/UL 2034 listed and IAS certi- fi ed.
62D4036 39 NOTES.
September 200 6 P /N 62D4036 • Rev . 8 LIMITED LIFETIME W ARRANTY POLICY LIFETIME W ARRANTY The following components are warranted for life to the original owner , subject to proof of purchase: Firebox, Combustion Chamber , Heat Exchanger , Grate and Stainless Steel Burners.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Monessen Hearth BBV400 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Monessen Hearth BBV400 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Monessen Hearth BBV400, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Monessen Hearth BBV400 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Monessen Hearth BBV400, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Monessen Hearth BBV400.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Monessen Hearth BBV400. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Monessen Hearth BBV400 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.