Air-conditioner Network System Centralized Controller AG-150A GB-50ADA-A GB-50ADA-J I n s t r u c t i o n B o o k (Web browser for User) Contents 1 Introduction ............................................................................. 1 1-1 Terms Used in this Manual .
1 1 Introduction Special features of Mitsubishi Electric Corporation’s “Centrali zed Controller AG-150A,” “Centralized Controller GB-50ADA-A,” and “Centralize d Controller GB-50ADA-J” are that a PC conn ected to a LAN can be used to monitor the operation condition of air co nditioners and perfo rm air conditioner operations.
2 2 Setting the Operating Environment PC settings and web brow ser settings required for usi ng a web browser to monitor air cond itioner units and perform operations are explaine d in the following pages. 2-1 Setting the PC IP Address Set an IP address on the PC that enable s AG-150A to connect via a web bro wser.
3 (4) In the [Internet Protocol (TCP/IP) P roperties] dialog, cli ck [Use the following IP address] and enter the IP address (for exa mple, “192.168.1.101”) that you want to set in the IP address field. You normally set [255.255.255. 0] as the subnet mask.
4 2-2 Setting the Web Browser Necessary web browse r settings mu st be performed to enable the web browser to connect to the AG-150A . Note: The settings and screen images used as examples in this manual ar e base d on Internet Explorer 6.
5 2-2-3 Connecting to the Internet using a proxy server (Using an existing LAN) If the PC you use for monitoring air c onditioners and p erforming operations is going to acce ss the Internet via proxy.
6 2-3 Setting the Java Execution Environment When using Java Plug-in versi on 1.6.0_ 10 or later, ma ke the following environment settings (not required for version 1.6.0_09 or earlier). Note: The setting samples and screenshots used in this m anual are those of Java Plug-in version 1.
7 3 Performing Operations Text below explains how t o connect to the AG -150A and how to monitor and adjust the operation co ndition of air conditioners. Follow the directio ns given here when performing operatio ns. Note: If the AG-150A is restarted due to a power interruption et c.
8 3-1-2 Encrypting the communication data and login on the AG-150A AG-150A can encrypt communication d ata using HTTPS (SSL). When connecting the AG-150A to the LAN that can be accessed by the general public, it is recommended that the following settings be made so that the units are monitore d and controlled on the encrypted Web page.
9 (4) If the security alert has not been disabled, after enter ing the web address an d hitting the Enter (Return ) key, a security alert message will alert aski ng if you want to proceed. This is bec ause the AG-150A uses the self-authentication system.
10 3-2 Checking the Operation Condition When you login correctly using the Login Screen, the sc reen used to monitor the operation condition s of air conditioner and general e quipment and hot water supply groups will appea r. If you wish to operate, click the group icon to switch to the operation screen.
11 Item Description Group icon (2) Ventilator (Lossnay) group operatio n co ndition Note: When connecting multiple AG-150A controllers by connecting an Expansion Controller to th e system, “Schedule set” and “Energy saving” will be di splayed only on the AG-150A controller that is executing these functions.
12 3-3 Performing the Operations Text below explains how to perfo rm air conditione r or general equipment or hot water supply operations. 3-3-1 Performing the operations that target one group When you click on a group icon in the operation co ndition monitoring screen, the operation screen for that group will appear.
13 Item Description Interlocked ventilator ON/OFF *1 Click [ON] or [OFF] to switch inte rlocked ventilator ON or OFF. Note: For groups that are not c onnected to an interl ocked ventilator, the items related to interlocked ventilators are not displayed.
.
This product is designed and inte nded for use in the residential, commercial and light-industrial environment. The product at hand is • Low Voltage Directive 2006/95/EC based on the following • E.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Mitsubishi Electronics GB-50ADA-A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Mitsubishi Electronics GB-50ADA-A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Mitsubishi Electronics GB-50ADA-A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Mitsubishi Electronics GB-50ADA-A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Mitsubishi Electronics GB-50ADA-A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Mitsubishi Electronics GB-50ADA-A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Mitsubishi Electronics GB-50ADA-A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Mitsubishi Electronics GB-50ADA-A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.