Manuel d'utilisation / d'entretien du produit XMT 304 CC/CV du fabricant Miller Electric
Aller à la page of 40
Processes Multiprocess W elding OM-233 045C 2007 − 10 Description Arc W elding Power Source XMT 304 CC/CV (400 V olt Models) (RoHS) R V isit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
dec_con1_1/07 Declaration of Conformity For European Community (CE) Products . This information is provided for units with CE certification (see rating label on unit). Manufacturer : European Contact: Miller Electric Mg. Co. Mr . Danilo Fedolfi, 1635 W .
OM-233 045 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _2007 − 04 7 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury .
OM-233 045 Page 2 W elding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. FUMES AND GASES can be hazardous. D Keep your head out of the fumes. Do not breathe the fumes. D If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.
OM-233 045 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-233 045 Page 4 1-4. California Proposition 65 W arnings W elding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer . (California Health & Safety Code Section 25249.
OM-233 045 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION fre_som_2007 − 04 7 Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-233 045 Page 6 Il reste une TENSION DC NON NÉGLIGEABLE dans les sources de soudage onduleur quand on a coupé l’alimentation. D Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie Entretien avant de toucher les pièces.
OM-233 045 Page 7 LES ACCUMULA TIONS DE GAZ risquent de provoquer des blessures ou même la mort. D Fermer l’alimentation du gaz protecteur en cas de non-utilisation. D V eiller toujours à bien aérer les espaces confi- nés ou se servir d’un respirateur d’adduction d’air homologué.
OM-233 045 Page 8 LES FILS DE SOUDAGE peuvent provoquer des blessures. D Ne pas appuyer sur la gâchette avant d’en avoir reçu l’instruction. D Ne pas diriger le pistolet vers soi, d’autres per- sonnes ou toute pièce mécanique en enga- geant le fil de soudage.
OM-233 045 Page 9 2-5. P r i nc ip al e s no r m e s de sé c ur i té Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www .
OM-233 045 Page 10.
OM-233 045 Page 1 1 SECTION 3 − DEFINITIONS 3-1. Manufacturer ’ s W arning Label Definitions W arning! W atch Out! There are possible hazards as shown by the symbols. 1 Electric shock from welding electrode or wiring can kill. 1.1 W ear dry insulating gloves.
OM-233 045 Page 12 > 60 s V S-179 190-A V V 1 Warning! W atch Out! There are possible hazards as shown by the symbols. 2 Electric shock from wiring can kill. 3 Disconnect input plug or power before working on machine. 4 Hazardous voltage remains on input capacitors after power is turned off.
OM-233 045 Page 13 3-2. Manufacturer ’ s Rating Label Ref. 235 855-A 3-3. WEEE Label Do not discard this product with general waste. Reuse or recycle Waste Electrical and Electronic Equipment (WEEE) by disposing at a designated collec- tion facility .
OM-233 045 Page 14 3-4. Symbols And Definitions A Amperage Panel Alternating Current (AC) V V oltage Output Circuit Breaker Remote On Of f Gas Tungsten Arc W elding Negative V oltage Input Direct Curr.
OM-233 045 Page 15 SECTION 4 − INST ALLA TION 4-1. Specifications Rated W elding Output V oltage Range Amperage Range Maximum Open-Circuit V oltage DC IP Rating Amperes Input at Rated Load Output 50/60 Hz Output Range Range V o l tage DC 400 V KV A KW 300 A @ 32 V olts DC, 60% Duty Cycle 10 − 35 5 − 400 90 23 17.
OM-233 045 Page 16 4-3. V olt-Ampere Curves va_curve1 4/95 − SA-178 652 / SA-178 653 V olt-ampere curves show minimum and maximum voltage and amper- age output capabilities of unit. Curves of other settings fall be- tween curves shown. A. CC Mode B.
OM-233 045 Page 17 4-4. Selecting A Location loc_2 3/96 - ST -801 192 1 Lifting Handles Use handles to lift unit. 2 Hand Cart Use cart or similar device to move unit. 3 Plate Label Use label to determine input power needs. 4 Line Disconnect Device Locate unit near correct input power supply .
OM-233 045 Page 18 4-5. W eld Output T erminals And Selecting Cable Sizes ! ARC WELDING can cause Electromagnetic Interference. T o reduce possible interference, keep weld cables as short as possible, close together , and down low , such as on the floor .
OM-233 045 Page 19 4-6. Remote 14 Receptacle Information Socket* Socket Information 24 VOL TS AC A 24 volts ac. Protected by circuit breaker CB2. AJ B K I 24 VOL TS AC B Contact closure to A completes 24 volts ac con- tactor control circuit. B I C L NH 1 15 VOL TS AC I 1 15 volts ac.
OM-233 045 Page 20 4-8. Electrical Service Guide NOTICE − INCORRECT INPUT POWER can damage this welding power source. This welding power source requires a CONTINUOUS supply of input power at rated frequency (+ 10%) and voltage (+ 10%). Phase to ground voltage shall not exceed +10% of rated input voltage.
OM-233 045 Page 21 4-9. Connecting 3-Phase Input Power 2/04 - Ref. 802 136-A / 801 192 ! Installation must meet all National an d Local Codes − have only quali- fied persons make this installation. ! Disconnect and lockout/tagout in- put power before connecting input conductors from unit.
OM-233 045 Page 22 SECTION 5 − OPERA TION 5-1. Front Panel Controls 1 Power On/Of f Switch . The fan motor is thermostatically controlled and only runs when cooling is needed.
OM-233 045 Page 23 5-2. Meter Functions . The meters display the actual weld output values for approximately three seconds after the arc is broken. Mode Meter Reading At Idle Scratch Start TIG (GT AW) Actual V olts (OCV) Preset Amps VA 80.
OM-233 045 Page 24 5-3. Mode Switch Settings . Th e SMA W modes provide the Adaptive Hot Start ™ feature, which automatically increases the output amperage at the start of a weld should the start require it. This eliminates electrode sticking at arc start.
OM-233 045 Page 25 5-4. Lift-Arc T rigger Hold TIG 1 TIG Electrode 2 W orkpiece . Procedure requires: Start sequence: • T ouch tungsten electrode to workpiece at weld start point. • Momentarily depress output switch. • Slowly lift electrode. An arc will form when electrode is lifted.
OM-233 045 Page 26 SECTION 6 − MAINTENANCE & TROUBLESHOOTING 6-1. Routine Maintenance . Maintain more often during severe conditions. ! Disconnect power before maintaining.
OM-233 045 Page 27 6-3. V oltmeter/Ammeter Help Displays . Al l directions are in reference to the front of the unit. All circuitry referred to is lo- cated inside the unit. 1 Help 0 Display Indicates a shorted thermistor R T2 on the left side of the unit.
OM-233 045 Page 28 6-4. T roubleshooting T rouble Remedy No weld output; unit completely inop- erative Place line disconnect switch in On position (see Section 4-9). era ti ve. Check and replace line fuse(s), if necessary , or reset circuit breaker (see Section 4 -9).
OM-233 045 Page 29 SECTION 7 − ELECTRICAL DIAGRAM 197 552 Figure 7-1. Circuit Diagram For Welding Power Source.
OM-233 045 Page 30 SECTION 8 − P ARTS LIST 801 605-H Figure 8.1. Parts Assembly.
OM-233 045 Page 31 Description Part No. Dia. Mkgs. Item No. Figure 8.1. Parts Assembly Quantity 1 +175 148 Wrapper 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-233 045 Page 32 Description Part No. Dia. Mkgs. Item No. Figure 8.1. Parts Assembly (Continued) Quantity 44 Z1 173 570 Stabilizer 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes Over 80,000 trained since 1930! 400 T rade Square East, T roy , Ohio 45373 1-800-332-9448 www.weldin g .or g Star t Y our Professional W eldin g Career Now!.
Notes SOCKET/WRENCH SELECTION T ABLE (U.S. ST ANDARD) SOCKET/WRENCH SELECTION T ABLE (METRIC) Specifications Socket or Wrench Size Specifications Socket or Wrench Size Bolt Diameter Decimal Equivalent Bolt Nut Bolt Diameter U.S. Decimal Equivalent Bolt Nut 1/4 in .
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2007 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2007 Miller Electric Mfg. Co. 2007 − 01 Miller Elect ric Mfg. Co. An Illinois T ool Wo rks Compan y 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarter .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Miller Electric XMT 304 CC/CV c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Miller Electric XMT 304 CC/CV - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Miller Electric XMT 304 CC/CV, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Miller Electric XMT 304 CC/CV va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Miller Electric XMT 304 CC/CV, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Miller Electric XMT 304 CC/CV.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Miller Electric XMT 304 CC/CV. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Miller Electric XMT 304 CC/CV ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.