Manuel d'utilisation / d'entretien du produit S-32S du fabricant Miller Electric
Aller à la page of 28
Visit our website at www.MillerWelds.com OM-1546 090 004M August 2000 Processes Description MIG (GMA W) W elding Flux Cored (FCA W) W elding Wire Feeder S-32S And S-32SL.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-1546 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_4/98 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message.
OM-1546 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.
OM-1546 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-1546 Page 4 1-5. EMF Information Considerations About W elding And The Effects Of Low Frequency Electric A n d M a g netic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields.
OM-1546 Page 5 SECTION 1 – CONSIGNES DE SECURITE – LIRE A V ANT UTILISA TION som _nd_fre 4/98 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette proc é dure pr é sente des risques de danger ! Ceux-ci sont identifi é s par des symboles adjacents aux directives.
OM-1546 Page 6 Le rayonnement de l ’ arc du proc é d é de soudage g é n è re des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des br û lures dans les yeux et sur la peau. Des é tincelles sont projet é es pendant le soudage.
OM-1546 Page 7 1-3. Dangers suppl é mentaires en relation avec l ’ installation, le fonctionnement et la maintenance Risque D ’ INCENDIE OU D ’ EXPLOSION. D Ne pas placer l ’ appareil sur , au-dessus ou à proxi- mit é de surfaces infllammables.
OM-1546 Page 8 1-4. Principales normes de s é curit é Safety in W elding and Cutting, norme ANSI Z49.1, de l ’ American Wel- ding Society , 550 N.W . Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.
OM-1546 Page 9 SECTION 2 – INST ALLA TION 2-1. Specifications T ype Of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range Input W elding Circuit Rating Max.
OM-1546 Page 10 2-2. Installing And Aligning Wire Guide And Drive Roll 3/16 in Ref. ST-091 547-D / Ref. ST -1 12 370-C / S-0856 When changing wire size or type, check drive roll and wire guide size (see Parts List).
OM-1546 Page 1 1 1 CV Welding Power Source With 24 V AC Power 2 CC Welding Power Source Without Contactor 3 External Secondary Contactor 4 Remote Contactor Cord 5 Weld Cable 6 W ork 2-3. T ypical Connections 1 6 5 6 5 3 2 4 1 Gun Securing Knob 2 Gun Block 3 Gun Outlet Wire Guide Loosen knob, insert gun into block.
OM-1546 Page 12 1 Gas Hose With 5/8-18 Right- hand Thread Fittings (Cus- tomer Supplied) 2-5. Connecting Shielding Gas (Optional) Ref. ST-158 789 T ools Nee d e d : 1 5/8 in 2-6.
OM-1546 Page 13 1 Pressure Assembly Adjust- ment Knob Lay gun cable out straight. A Open pressure assembly , hold wire tightly , and cut of f end. Push wire through guides into gun. B Close and tighten pressure assembly . Press gun trig- ger until wire comes out gun.
OM-1546 Page 14 SECTION 3 – OPERA TION 3-1. Controls Ref. ST-091 547-D / ST -176 214 2 4 Selector Switch for T ype of Power Source Constant V oltage CV Constant Current (drooper) CC S-090 438-D 1 Wire Speed Control (See Sec- tion 3-2) 2 Power Control Switch 3 Circuit Breaker CB1 CB 1 protects wire feeder from over- load.
OM-1546 Page 15 Wire Speed Setting CC Mode 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 222 254 268 295 314 342 365 388 406 429 452 480 498 526 549 572 595 623 205 234 246 271 288.
OM-1546 Page 16 SECTION 4 – MAINTENANCE & TROUBLESHOOTING 4-1. Routine Maintenance Y Disconnect power before maintaining. 3 Months Replace Unreadable Labels Clean And T ighten W eld T erminals R.
OM-1546 Page 17 SECTION 5 – ELECTRICAL DIAGRAM SB-176 227 Figure 5-1. Circuit Diagram For Wire Feeder.
OM-1546 Page 18 SECTION 6 – P ARTS LIST Figure 6-1. Main Assembly ST-091 506-K . Hardware is common and not available unless listed. 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 15 14 17 18 19 22 21 20 12 23 24 25 26 27 28 29 30 – FIG.
OM-1546 Page 19 Figure 6-1. Main Assembly Description Quantity Part No. Dia. Mkgs. Item No. 1 097 770 LABEL, warning electric shock can kill 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 +089 818 WRAPPER 1 .
OM-1546 Page 20 Figure 6-2. Motor & Wire Drive Assembly (Fig 6-1 Item 30) Description Quantity Part No. Dia. Mkgs. Item No. 1 166 338 LEVER, mtg pressure gear 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-1546 Page 21 T able 6-1. Drive Roll & Wire Guide Kits Base selection of drive rolls upon the following recommended usages: 1. V -Grooved rolls for hard wire. 2. U-Grooved rolls for soft and soft shelled cored wires. 3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).
OM-1546 Page 22 Notes.
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 7/00 Y o ur distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor .
PRINTED IN USA 2000 Miller Electric Mfg. Co. 6/00 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Com pany 1635 W est S pencer St reet Applet on, WI 54914 USA International He adquarters –.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Miller Electric S-32S c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Miller Electric S-32S - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Miller Electric S-32S, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Miller Electric S-32S va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Miller Electric S-32S, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Miller Electric S-32S.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Miller Electric S-32S. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Miller Electric S-32S ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.