Operating and installation instructions Cooker hood DA 5960 W, DA 5990 W, DA 5990 W EXT To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time.
Caring for the environment ..........................................3 Warning and Safety instructions .....................................4 Guide to the appliance ............................................1 0 Modes of operation ...................
Disposal of the packing material The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and can normally be recycled. Packaging e.g. cling film, polystyrene and plastic wrappings must be kept out of the reach of babies and young children.
This appliance complies with all relevant local and national safety requirements. Inappropriate use can, however, lead to personal injury and damage to property. To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before using it for the first time.
Technical safety ~ Before installation, check the cooker hood for visible signs of damage. Under no circumstances should you use a damaged appliance. A damaged appliance is dangerous.
~ Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension lead. These do not guarantee the required safety of the appliance (e.g. danger of overheating). ~ For appliances with an external fan motor fitted (.
In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure of 0.04 mbar (4 pa) is the maximum permissible in the room.
Correct use ~ Never use an open flame beneath the cooker hood. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the cooker hood could draw flames into the filter. Fat particles drawn into the cooker hood present a fire hazard.
~ Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. ~ All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. ~ The appliance must not be connected to a chimney or vent flue which is in use.
Guide to the appliance 10 dai2406.
a Telescopic extension piece b Tower c Controls d Hob lighting e Recirculation grille (only for recirculation mode) f Canopy g Charcoal filter (accessory required for recirculation mode) h Grease filt.
The cooker hood works with . . . air extraction: The air is drawn in, cleaned by the grease filter and then directed outside. If the on-site ventilation system does not have a non-return flap , then the non-return flap supplied with the appliance must be fitted in the exhaust socket in the motor unit.
To switch the fan on ^ Press the On/Off control. The fan will come on at power level lI. If the cooker hood has been connected to a window contact switch via the Miele DSM 400 control module, then the fan cannot be switched on if the window is shut. The indicator lamp will flash.
Automatic switch-off of the Intensive setting You can set the Intensive setting so that it only runs for 10 minutes before reverting automatically to level III.
Before any cleaning or maintenance work is carried out, disconnect the cooker hood from the mains supply. Ensure that: – it is switched off at the isolator, or – it is switched off at the wall soc.
Controls The controls may suffer discolouration or damage if soiling is left on them for too long. Remove soiling straight away. Observe the General notes on cleaning earlier in this section. Do not use stainless steel cleaning agents on the controls.
Cleaning the grease filter by hand ^ Clean the filter with a soft nylon brush in a mild solution of hot water and a little washing-up liquid. Do not use "neat" washing up liquid. Do not use: – cleaning agents containing descaling agents, – powder cleaners, cream cleaners or abrasive all-purpose cleaners.
Fitting and replacing the charcoal filter If the cooker hood is connected for recirculation, a charcoal filter must be inserted in addition to the grease filter. This is designed to absorb cooking odours. It is fitted in the canopy above the grease filter.
Changing a halogen lamp , Before any cleaning or maintenance work is carried out, disconnect the cooker hood from the mains supply. Ensure that: – it is switched off at the isolator, or – it is sw.
The diagram is not drawn to scale. Appliance dimensions 20.
a Extraction b Recirculation c Ventilation grill positioned at the top for recirculation d , e The shaded areas represent the wall or ceiling area for the vent cut-out and for fitting the connection socket. For recirculation mode, you only require cut-out area 4) and a connection socket.
– When deciding on the safety distance between the hob and cooker hood, please note that a distance of 650 mm above electric cookers/hobs may be preferable to give more working space under the hood. – Account should also be taken of the height of the person who will be using the hood most often.
Before installation, it is important to read the information given on the following pages as well as the "Appliance dimensions" and the "Warning and Safety instructions" at the beginning of this booklet.
Assembly parts Installation 24 dai2411.
a 3 protective sheets for use when fitting the tower. b 2 hose clips for securing the exhaust ducting. c 1 reducing collar for C 125 mm exhaust ducting. d 1 non-return valve for fitting into the exhaust connection on the motor unit (not for recirculation mode).
Important: To avoid the danger of toxic fumes please observe the Warning and Safety instructions. This is especially crucial when using the cooker hood at the same time as another heating appliance which relies on air from the same room. The cooker hood should be installed according to local and national building regulations.
Important: If the exhaust ducting is to run through rooms, ceiling space etc. where there may be great variations in temperature between the different areas, the problem of condensation will need to be addressed. The exhaust ducting will need to be suitably insulated.
All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer cannot be held liable.
The Miele DSM 400 Control module can be used to combine the cooker hood with other components. It enables the following: Connection to a window contact switch If adequate ventilation to the room can o.
Connection to a light switch The control module can be used to switch on the cooker hood lighting via a light switch in the house. Installation The tower needs to be removed before the control module can be fitted to the fan unit. The control module is supplied with its own detailed operating and installation instructions.
In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – Your Miele Dealer / Chartered Agent or – The Miele Customer Contact Centre (see back cover for address). When contacting your Dealer or Miele, please quote the model and serial number of your appliance.
Total connected load ..........2 5 0W - Fan motor .................2 0 0W - Hob lighting ..............1x5 0W Voltage ................. A C2 3 0V Frequency .................. 5 0H z Fuse rating ....................5A Electrical cable length .........1 .
33.
34.
35.
Alteration rights reserved / 4209 M.-Nr. 07 598 080 / 01.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Miele DA 5990 W Ext c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Miele DA 5990 W Ext - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Miele DA 5990 W Ext, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Miele DA 5990 W Ext va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Miele DA 5990 W Ext, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Miele DA 5990 W Ext.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Miele DA 5990 W Ext. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Miele DA 5990 W Ext ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.