Manuel d'utilisation / d'entretien du produit Micronix 1800 Series du fabricant Micro Technic
Aller à la page of 21
Micro Technic A -S • Den mark • Tel. +45 66 15 3000 • Fax +45 6615 3077 E-mail: suppo rt@micro-technic.co m Website: www. micro-technic.co m M ICRONIX PC/104 P OWER S UPPLY PV-1700, 1800 SERIES 20W Power Supply including GSM/G PRS modem, analogue and digital I/O channels V ER .
Page 2 / 21 Table of contents GENERAL INFORMATION .......................................................................................................................................... 2 O RDERING CODES ............................................
Users Manual & Installation G uide PV- 180 0: Power supply module with GSM MODEM Page 3 / 21 General informatio n Ordering codes Options Ordering no Model no -S - Power Supply Modem Analog inputs Digital inputs Digital outputs RS232 PV-1700 -1 016.
Page 4 / 21 Accessories These accessories must be ordered separately if needed. Model no Ordering code Description GSM cable 126.033.000 RG136 cable with MMCX-S MA MALE 140mm GSM Antenna 060.302.001 GSM antenna w ith SMA co nnector CM-2 425.104.001 Mains cable with one crim p connector mating KL1, 30c m CDB-9M 425.
Users Manual & Installation G uide PV- 180 0: Power supply module with GSM MODEM Page 5 / 21 Description The PV-1800, the fully equipped model, offers the following features: • a PC/104 20W power supply +5V, 4A.
Page 6 / 21 The digital I/O section is found on all models except PV-1830 and PV-1730 versions. The digital inputs are bipolar isolated with a max. input voltage of +/- 30V. There are 7 isolated digital P-channel outputs each capable of drivin g up to 0.
Users Manual & Installation G uide PV- 180 0: Power supply module with GSM MODEM Page 7 / 21 Power Supply The on-board power supply consists of a synchronous step-down switching regulator with an efficiency of 85-95%, depending on input voltage and load current.
Page 8 / 21 This table is also printed on the board. The IRQ used for the modem is set in section I RQ_A. Place one jumper in this s ection to select an IRQ number in the interval IRQ3 to IRQ15. SIM card The SIM card connector (CN9) is placed on the rear side of the module.
Users Manual & Installation G uide PV- 180 0: Power supply module with GSM MODEM Page 9 / 21 AT commands All functions of the modem are carried out by AT commands from a computer application. For documentation of the AT command set please see “Integrators Manual” for GM47 from Son y Ericsson, at http://www.
Page 10 / 21 Function Pin no CN9 Pin no CDB-9M I/O GND 1 5 RI 2 9 I DTS 3 4 O CTS 4 8 I TxD 5 3 O RTS 6 7 O RxD 7 2 I DSR 8 6 I CD 9 1 I N.C. 10 .
Users Manual & Installation G uide PV- 180 0: Power supply module with GSM MODEM Page 11 / 21 Analogue inputs (CN5) The PV-1800 and PV-1700 has 8 isolated analogue inputs accessible in a 10pin box header (CN5). Beside these inputs, there is also a +3.
Page 12 / 21 Digital inputs (CN 1) All models, except PV-1830 and PV-1730 has 8 isolated digital inputs con nected to a 10-pin box header (CN1). All the inputs have ac-couplers with a common ground reference. Because of the ac- couplers, the inputs can be activated with positive as well as negative input voltages.
Users Manual & Installation G uide PV- 180 0: Power supply module with GSM MODEM Page 13 / 21 Digital outputs (CN2) The digital section has 7 isolated digital outputs connected to a 10pin box header (CN2). The outputs are configured as PNP outputs with their transistors connected to an external supply voltage (+V_EXT).
Page 14 / 21 UPS signals (CN7) Modules with onboard DC/DC converter has signals that, combined with e xternal circuitry, can be used to implement a UPS function.
Users Manual & Installation G uide PV- 180 0: Power supply module with GSM MODEM Page 15 / 21 Internal registers Address Access Name Function Base+0 Read onl y REG_SIGN Signature (8Ch) Base+1 Read.
Page 16 / 21 REG_CNTMODE (base+6): Counter configuration (read/write) The counter starts at 0000h after system reset. It cannot be reset or reloaded from software.
Users Manual & Installation G uide PV- 180 0: Power supply module with GSM MODEM Page 17 / 21 REG_ADCLO (base+0Ah): ADC command, status, and result low b y te (read/write) Writing to this register starts a new A/D conversion. You should onl y do this when the ADC is idle.
Page 18 / 21 Technical data Power supply Input voltage (nominal) 8 – 27Vdc. Input voltage (MAX) 35Vdc. Output voltage 5Vdc External load Up to 4A, depending on configuration and thermal conditions. UPS interface: 4 pins in CN7 Run/stop, AUX1,AUX2,AUX3 (factor y use onl y).
Users Manual & Installation G uide PV- 180 0: Power supply module with GSM MODEM Page 19 / 21 Max input voltage 30V, current limiti ng resistor = 3.32kohm / 250mW Counter input DI0 can act as a 16-bit up-counter by counting positive or negative edges (configurable) DI0 and DI1 can act as a 16-bit quadrature counter.
Page 20 / 21 Mechanical Lay o ut This schematic shows the dimensions for PV-1800. All dimensions are in mm..
Users Manual & Installation G uide PV- 180 0: Power supply module with GSM MODEM Page 21 / 21 Installation guide Precautions to ESD Please note that the Micronix PV modules must be handled with respect to ESD (Electrostatic Discharge). Electrostatic Discharge to the PV modules must be avoided.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Micro Technic Micronix 1800 Series c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Micro Technic Micronix 1800 Series - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Micro Technic Micronix 1800 Series, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Micro Technic Micronix 1800 Series va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Micro Technic Micronix 1800 Series, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Micro Technic Micronix 1800 Series.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Micro Technic Micronix 1800 Series. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Micro Technic Micronix 1800 Series ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.