R HIGH PRESSURE PORT ABLE FORCED AIR HEA TER OWNER’S MANUAL Model B350EAI 350 SIDE PFA/PV 008 IMPORTANT Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
2 099565 CONTENTS SECTION PAGE Safety Information .................................................................................... 3 Product Identification ............................................................................... 4 Unpacking .
3 099565 SAFETY INFORMA TION WARNING ICON G 001 W ARNINGS WARNING ICON G 001 DANGER Carbon monoxide poisoning may lead to death! IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, operate, or service this heater.
4 099565 PRODUCT IDENTIFICA TION Upper Shell Hot Air Outlet Lower Shell Fuel Cap Thermostat Fuel Tank Power Cord Motor and Pump Assembly Safety Control Reset Button Figure 1 - B350EAI BTU/Hr Model UNP ACKING 1. Remove all protective packing applied to heater for shipment.
5 099565 Front Handle Cotter Pin Rear Handle Screw Air Inlet Axle Extended Hub Nut Flat Washer Wheel Spacer Flat Washer Figure 2 - Wheel and Handle Assembly Wheel Wheel Support Frame Fuel Tank Flange .
6 099565 THEOR Y OF OPERA TION The Fuel System: The motor turns the fuel pump. The fuel pump pulls fuel from the fuel tank. The fuel pump pushes fuel through a filter and a solenoid valve and out the burner head nozzle. A fine mist of fuel is sprayed into the combustion chamber.
7 099565 FUELS Do not use heavy fuels such as No. 2 fuel oil or No. 2 diesel. Using heavy fuels will result in: • clogged fuel filter and nozzle • carbon build-up on spark plug • the need of non-toxic anti-icer in fuel during very cold weather IMPORTANT: Use a KEROSENE ONLY storage container.
8 099565 OPERA TION To Start Heater 1. Follow all ventilation and safety information. 2. Fill fuel tank with kerosene or No. 1 fuel oil. 3. Attach fuel cap. 4. Set thermostat dial to desired temperature. Note: Thermostat setting must be higher than surrounding air temperature.
9 099565 To Stop Heater WARNING ICON G 001 CAUTION Never unplug heater while heater is running. Heater must go through purge cycle. The purge cycle cools the combustion chamber. Damage to heater can occur if combustion chamber is not cooled. Do not restart heater until purge cycle is complete.
10 099565 How To See Storage , page 9. Lift out of fuel tank and rinse with clean kerosene. See Fuel Filters , page 17. See Fuel Lines , Page 16. See Fuel Filters , page 17. See Spark Plug , page 15. See Fan Blades, page 14. Remove dirt and trash with clean, soft cloth.
11 099565 OBSERVED PROBLEM TROUBLE- SHOOTING Motor does not start when heater is plugged in and thermostat setting is higher than surrounding air temperature. 1. No power or low voltage at heater due to: A) Damaged power cord or extension cord B) Wrong size extension cord C) Heater plugged into outlet with voltage lower than 220/240 volts 2.
12 099565 OBSERVED PROBLEM Heater will not ignite, but motor runs for a short period of time. 1. A) Add fuel to tank. B) Check fuel tank for bubbles of water in bottom. If found, remove fuel (see Storage , page 9). Clean tank and fuel filters (see Fuel Filters , page 17).
13 099565 OBSERVED PROBLEM Heater ignites, but safety control shuts off heater after a short period of time. 1. Wrong pump pressure 2. Dirty fuel filters 3. Dirt in nozzle 4. Dirty photocell lens 5. Open or damaged photocell 6. Bad safety control 7. Damaged fan switch 1.
14 099565 SER VICE PROCEDURES Upper Shell Removal 1. Remove screws along each side and top of heater using 5/ 16" nut-driver. These screws attach upper and lower shells together (see Figure 5). 2. Lift upper shell off. Figure 5 - Upper Shell Removal Fan Blades 1.
15 099565 Nozzle 1. Remove upper shell (see page 14). 2. Remove fuel line from solenoid valve using 7/16" wrench. 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Remove five (5) screws using 5/16" nut-driver and remove burner head from combustion chamber.
16 099565 psi Pump (Procedure if pump is binding) 1. Remove upper shell (see page 14). 2. Loosen hex screw on flange clamp at rear of motor with 5/16" nut-driver (see Figure 11). 3. Turn fan with hand (see Figure 12). 4. If fan turns freely, tighten screw on flange clamp.
17 099565 Fuel Filter Fuel Lines Pump Pump Fuel Filter Assembly Figure 15 - Removing Tank Fuel Filter B. Pump Fuel Filter 1. Unscrew canister bottom from canister top with Channellock pliers. 2. Remove fuel filter and gasket from canister bottom (see Figure 16).
18 099565 WIRING DIAGRAM SPECIFICA TIONS 1 3 2 Fan Switch 75 BA Motor Relay White Red Orange Orange Red Black White Black White Blue Blue White Black Black Thermostat B R Safety Control Reset Button R.
19 099565 4 1 2 3 5 6 7 8 9 10 11 12 8 13 14 15 16 17 18 20 19 21 22 (3) 23 24 25 27 26 28 29 30 31 REF. NO. PART NO. DESCRIPTION QTY. 1 097495-02AA Wiring cover 1 2 HF5-5C Screw, 5/16-24 x 5/16".
20 099565 ILLUSTRA TED P ARTS BREAKDOWN 1 2 2 2 7 8 9 10 13 11 12 14 15 16 17 18 41 19 20 21 4 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 37 38 34 2 39 2 40 5 6 20 13 3.
21 099565 P ARTS LIST REF. NO. PART NO. DESCRIPTION QTY. 1 099329-02 Upper shell 1 2 M11084-27 Screw, #10-16 x 1/2" 25 3 M50542-01 Combustion chamber & shield 1 4 M30865-02 Bushing 3 5 100057.
22 099565 NOTES _______________________________________________________________ _______________________________________________________________ ________________________________________________________.
23 099565 NOTES _______________________________________________________________ _______________________________________________________________ ________________________________________________________.
24 099565 W ARRANTY AND REP AIR SER VICE 099565-01 Rev. C 07/94 INTERNA TIONAL POSE. IN ANY EVENT IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PAR- TICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Master Lock B350EAI c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Master Lock B350EAI - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Master Lock B350EAI, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Master Lock B350EAI va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Master Lock B350EAI, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Master Lock B350EAI.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Master Lock B350EAI. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Master Lock B350EAI ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.