Manuel d'utilisation / d'entretien du produit KNIGHT 210 du fabricant Lochinvar
Aller à la page of 20
User ’ s Information Manual Models: 50 - 210 If the information in this manual is not followed exactly , a fir e or explosion may r esult causing property damage, personal injury or loss of life. This appliance MUST NO T be installed in any location where gasoline or flammable vapors are likely t o be present.
2 Hazar d definitions The following defined terms are used thr oughout this manual to bring attention to the presenc e of hazards of var ious risk level s or to important information concerning the life of the product.
User ’s Information Manual Please r ead bef ore pr oceeding The Knight W all M ount Installation and Operation Manual along with the Knight W all Mount Service Manual ar e for use only by a qualified heating installer/serv ice technician. Refer only to this U ser’ s Information Manual for your referenc e.
User ’s Information Manual 1 Prev ent combustion air contamina tion 4 If the boiler combustion air inlet is located in a laundry room or pool facility , for example, these areas will always contain hazar dous contaminants.
User ’s Information Manual 2 Maintenance sc hedule 5 Ser vice tec hnician (see the Knight W all Mount Service Manual) General: • Reported problems • Inspect interior; clean and vacuum if necessa.
User ’s Information Manual 2 Maintenance sc hedule 6 Maintenance procedur es Boiler must be ser viced and maintained W ARNING The boiler must be inspected and started annually at the beginning of the heating season by a qualified serv ice tec hnician.
User ’s Information Manual 2 Maintenance sc hedule (continued) 7 4. Fill with fresh water until the water begins to pour out of the drain. 5. Replac e the cap. Press the cap onto the trap until the cap makes c ontac t with the drain. 6. Replac e the retaining screw .
User ’s Information Manual 2 Maintenance sc hedule 8 W ARNING Ha ve leaks fixed at onc e by a qualified serv ice technician. Failure to c omply could result in sever e personal injur y , death, or substantial property damage. Operate relief valv e 1.
User ’s Information Manual 9 3 Oper a ting instr uctions.
User ’s Information Manual 10 4 SMART SY STEM contr ol module Figure 4-1 Control Panel Knight wall mount control module U se the control panel (FIG. 4-1) to set temperatures, oper ating conditions, and monitor boiler operation.
User ’s Information Manual 11 Access modes User The user can adjust space heating target temperatur e by using the UP and DO WN buttons (FIG. 4-1) at any time during normal operation. By ent ering the USER code (0704), the user can also change temperature units, time and date, and night setback settings.
User ’s Information Manual 12 4 SMART SY STEM contr ol module Parameter table MENU SUB ITEM DESCRIPTION SEE PAGE USER ACCESS INSTALLER ACCESS DISPLAY MODIFY DISPLAY MODIFY A 1 Boiler Model 14 Ye s N.
User ’s Information Manual 13 A: General Boiler model The control will displa y “Knight Boiler” as the model number because the same contr ol is used on several models. This w ill be display ed when parameter A1 has been accessed. This parameter is not changeable.
User ’s Information Manual 14 4 SMART SY STEM contr ol module E: DHW settings DHW boiler set point W hen a DHW call for heat becomes acti ve, the control will use the DHW boiler set point to determine the firing rate of the boiler based on the actual water temperatur e.
User ’s Information Manual 15 Status Display Screens By using the P revious/Next ( , ) arrow k eys on the SMAR T SYSTEM display panel, you can navigate through the eight (8) display scr eens.
User ’s Information Manual 16 4 SMART SY STEM contr ol module Status Display Screens (cont ’ d) By using the Pr e vious/Next ( , ) arrow k eys on the SMAR T SYSTEM display panel, you can navigate through the eight (8) display scr eens. Each screen will contain two (2) viewable items.
User ’s Information Manual 17 Status Display Screens (cont ’ d) By using the P revious/Next ( , ) arrow k eys on the SMAR T SYSTEM display panel, you can navigate through the eight (8) display scr eens. Each screen will contain two (2) viewable items.
User ’s Information Manual 18 4 SMART SY STEM contr ol module Status Display Screens (cont ’ d) Operation of the cascade The boiler designated as the Leader will have tw o additional display screens that can be viewed. These screens will provide information regarding the operation of the Cascade.
19 User ’s Information Manual Notes.
Revision Notes: Revision B (ECO #C02545) reflects changes made to the “Check Air Piping” section on page 6 along with the addition of references to periodic cleaning of screens in vent terminations. Revision C (ECO #C02940) reflects changing 0° to 32°F under the Night Setback Times section on page 13.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lochinvar KNIGHT 210 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lochinvar KNIGHT 210 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lochinvar KNIGHT 210, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lochinvar KNIGHT 210 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lochinvar KNIGHT 210, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lochinvar KNIGHT 210.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lochinvar KNIGHT 210. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lochinvar KNIGHT 210 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.