Manuel d'utilisation / d'entretien du produit RED-D-ARC FX450 du fabricant Lincoln Electric
Aller à la page of 31
RED-D-ARC FX450 IM10094 February, 2011 Red-D-Arc Spec-Built W elding Equipment This RED-D-ARC welder is built to RED-D-ARC Extreme Duty design specifications by Lincoln Electric. Safety Depends on Y ou This welder is designed and built with safety in mind.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC R A Y S can bur n. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
iii SAFETY iii FOR ELECTRIC ALL Y pow er ed equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A LʼArc 1.
v v Thank Y ou for selecting one of our QUALITY products. We want you to take pride in operating this product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ......................................................................
FX450 (RED-D-ARC) A-1 INST ALLA TION A-1 TECHNICAL SPECIFICA TIONS - FX450 RA TED OUTPUT POWER SOURCE-INPUT VOL T AGE AND CURRENT Model K3073-1 Duty Cycle 60% rating 100% rating Volts at Rated Amperes 36.
A-2 INST ALLA TION FX450 (RED-D-ARC) A-2 PHYSICAL DIMENSIONS TEMPERA TURE RANGES HEIGHT 18.80in (478mm) MODEL K3073-1 WIDTH 14.14in (359mm) DEPTH 26.66in (677mm) WEIGHT 125lbs (56.
A-3 INST ALLA TION A-3 SELECT SUIT ABLE LOCA TION LOCATION AND VENTILATION FOR COOLING Place the welder where clean cooling air can freely circulate in through the rear louvers and out through the case sides. Dirt, dust, or any foreign material that can be drawn into the welder should be kept at a mini- mum.
A-4 INST ALLA TION A-4 INPUT FUSE AND SUPPL Y WIRE CONSIDERA TIONS Refer to Specification in this Installation Section for recommended fuse, wire sizes and type of the copper wires.
A-5 INST ALLA TION A-5 FX450 (RED-D-ARC) Pin A B C D E F Wiring 77 Remote potentiometer, 5K 76 Remote potentiometer, wiper 75 Remote potentiometer, common Trigger, common Trigger, input Ground CABLE CONNECTIONS See FIGURE A.2 for locating 6-pin and 14-pin con- nectors on the front of the FX450.
A-6 INST ALLA TION FX450 (RED-D-ARC) A-6 RECOMMENDED ELECTRODE AND WORK CABLE SIZES FOR ARC WELDING General Guidelines Connect the electrode and work cables between the appropriate output studs of the FX450 per the follow- ing guidelines: • Most welding applications run with the electrode being positive (+).
B-1 OPERA TION FX450 (RED-D-ARC) B-1 SAFETY PRECAUTIONS Read this entire section of operating instructions before operating the machine. ELECTRIC SHOCK can kill.
B-2 OPERA TION B-2 FX450 (RED-D-ARC) PRODUCT DESCRIPTION The FX450 is a multi-process CC/CV DC inverter and is rated for 450 amps, 38 volts at a 60% duty cycle. This machine is intended for both factory and field operation. It comes in a compact, rugged case that is designed for portability and outdoor use with an IP23 environmental rating.
B-3 OPERA TION B-3 RECOMMENDED PROCESSES AND EQUIPMENT RECOMMENDED PROCESSES The FX450 is designed for CC-SMAW, CC-GTAW (lift tig), CV-GMAW, CV-FCAW-SS and CV-FCAW-GS welding processes. CAG (arc gouging) is also supported. PROCESS LIMIT A TIONS The FX450 is suitable only for the processes listed.
B-4 OPERA TION B-4 CASE FRONT CONTROL DESCRIPTIONS (See Figure B.1) 1. Power Switch 2. Voltage Display Meter 3. Amperage Display Meter 4. Thermal LED 5. Output Control Dial 6. Weld Process Selector Switch 7. Hot Start Toggle Switch 8. Output Control Local/Remote Toggle Switch 9.
B-5 OPERA TION B-5 FX450 (RED-D-ARC) CASE BACK CONTROL (See Figure B.2) 1. Input Power Cord Access Hole. 1 1 FIGURE B.2 COMMON WELDING PROCEDURES MAKING A WELD The serviceability of a product or structure utiliz- ing the welding programs is and must be the sole responsibility of the builder/user.
B-6 OPERA TION B-6 Amperage Display Meter • Prior to STICK or TIG operation (current flow), the meter displays preset current value. • Prior to CV operation, the meter displays four dash- es indicating non-presettable AMPS. • During welding, this meter displays actual average amps.
B-7 OPERA TION B-7 GT A W This weld mode is a constant current (CC) mode featuring con- tinuous control from 10 – 500 amps. It is intended for the GTAW TIG welding processes. Hot Start - The Hot Start control regulates the starting current at arc initiation.
B-8 OPERA TION B-8 CV -INNERSHIELD This weld mode is a constant voltage (CV) mode fea- turing continuous control from 10 to 45 volts. It is intended for the FCAW-SS welding process and arc gouging. Hot Start – Toggle to “ON” position to provide more energy during the start of a weld.
C-1 ACCESSORIES C-1 OPTIONS / ACCESSORIES General Options K2149-1 Work Lead Package. K1842-10 10ft. Weld Power Cable (Lug to Lug). Inverter and Wire Feeder Cart Rear-wheeled cart includes front casters and no-lift gas bottle platform. Convenient handles allow for easy cable storage while full length side trays store parts and tools.
D-1 MAINTENANCE D-1 PERIODIC MAINTENANCE Thermal Protection Thermostats protect the machine from excessive operating temperatures. Excessive temperatures may be caused by a lack of cooling air or operating the machine beyond the duty cycle and output rating.
E-1 TROUBLESHOOTING E-1 FX450 (RED-D-ARC) If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 FX450 (RED-D-ARC) Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) POSSIBLE CAUSE RECOMMENDED COURSE OF ACTION Major physical or electrical damage is evident when the sheet metal covers are removed.
E-3 TROUBLESHOOTING E-3 FX450 (RED-D-ARC) Observe all Safety Guidelines detailed throughout this manual USING THE ST A TUS LED TO TROUBLESHOOT SYSTEM PROBLEMS Errors are displayed on the user interface. In addition, there are status lights on the control pc board and the switch pc board that contain error sequences.
F-1 DIAGRAMS F-1 FX450 (RED-D-ARC) NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-2 DIMENSION PRINT F-2 FX450 (RED-D-ARC) L15698 A.01 26.66 18.78 14.14 26.51 13.06 L15698 A.01 26.66 18.78 14.14 26.51 13.06.
W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERS T AND THE MANUF A CTURER’S INS TRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLL O W Y OUR EMPL O YER’S SAFETY PRA CTICES.
W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREEND A A S INSTR UÇÕES DO F ABRIC ANTE P ARA ES TE EQUIP AMENT O E AS P AR TES DE USO , E SIGA AS PRÁTIC A S DE SEGUR ANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lincoln Electric RED-D-ARC FX450 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lincoln Electric RED-D-ARC FX450 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lincoln Electric RED-D-ARC FX450, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lincoln Electric RED-D-ARC FX450 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lincoln Electric RED-D-ARC FX450, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lincoln Electric RED-D-ARC FX450.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lincoln Electric RED-D-ARC FX450. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lincoln Electric RED-D-ARC FX450 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.