Manuel d'utilisation / d'entretien du produit POWER WAVE IM716 du fabricant Lincoln Electric
Aller à la page of 46
PO WER W A VE 455/S TT ™ OPERA TOR’S MANUAL IM716 October, 2003 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications - POWER WAVE 455 ....................................................A-1 Safety Precautions.
vii vii T ABLE OF CONTENTS Page Troubleshooting ..............................................................................................Section E How to use Troubleshooting Guide ..................................................................
A-1 INST ALLA TION POWER WAVE 455/STT A-1 TECHNICAL SPECIFICA TIONS - POWER W A VE 455/STT (K1518-4) OUTPUT RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RA TED OUTPUT PHYSICAL DIMENSIONS TEMPERA TURE RANGES INPUT A T RA TED OUTPUT - THREE PHASE ONL Y INPUT VOLTS 208/230/460/575V - 60HZ.
LIFTING Lift the machine by the lift bail only. The lift bail is designed to lift the power source only. Do not attempt to lift the Power Wave with accessories attached to it. LIMIT ON ST ACKING F ALLING EQUIPMENT can cause injury. • Do not lift this machine using lift bale if it is equipped with a heavy accessory such as trailer or gas cylinder.
A-3 INST ALLA TION POWER WAVE 455/STT A-3 INPUT FUSE AND SUPPL Y WIRE CONSIDERA TIONS Refer to the Technical Specifications at the beginning of this Installation section for recommended fuse and wire sizes.
A-4 INST ALLA TION POWER WAVE 455/STT A-4 CABLE INDUCT ANCE, AND ITS EFFECTS ON PULSE WELDING For Pulse Welding processes, cable inductance will cause the welding performance to degrade. For the total welding loop length less than 50 feet, traditional welding cables may be used without any effects on welding performance.
A-5 INST ALLA TION POWER WAVE 455/STT A-5 Electrode Voltage Sensing Enabling or disabling electrode voltage sensing is automatically configured through software. The 67 electrode sense lead is internal to the cable to the wire feeder and always connected when a wire feeder is present.
A-6 INST ALLA TION POWER WAVE 455/STT A-6 SYSTEM DESCRIPTION The Power Wave 455/STT and Power Feed 10/11 family of products utilize a digital communication sys- tem called Linc-Net. Simply put, Linc-Net allows large amounts of information to be passed at very high speeds between components (nodes) in the system.
A-7 INST ALLA TION POWER WAVE 455/STT A-7 FIGURE A.8 Simple System SYSTEM SET -UP Basic Rules • Each group is required to have one user interface. No group may have more than one user interface. • Each group can have up to seven Feed Heads. Exception: Group 3 is limited to a maximum of six Feed Heads.
A-8 INST ALLA TION POWER WAVE 455/STT A-8 FIGURE A.9 Multiple Group System No “ FH0 Alllowed! FIGURE A.10 Single Group Multi-Head System No “ FH0 Alllowed! The Dual Head option allows the abil- ity to maintain 2 sets of procedures. If more then 2 heads are used, odd # ’ s use FH1 settings, even # ’ s use FH2 settings.
A-9 INST ALLA TION POWER WAVE 455/STT A-9 FIGURE A.1 1 Single Group Multi-Head System (Alternate Method) No “ FH0 Alllowed! When a standard User Iterface is used in a group with multi- ple Feed Heads, all of the Feed Heads use a single set of procedures.
A-10 INST ALLA TION POWER WAVE 455/STT A-10 FIGURE A.2 - + PO WERW A VE - + PO WERW A VE Connect All Work Sense Leads at the End of the Joint Connect All Welding Work Leads at the Beginning of the Joi.
A-11 INST ALLA TION POWER WAVE 455 A-11 MUL TIPLE ARC SENSE LEAD AND WORK LEAD PLACEMENT GUIDELINES Wor k # 2 Se ns e # 2 Pow er Source #2 Pow er Sourc e #1 Arc # 1 Arc #2 Wor k #1 Se ns e # 1 Work # .
A-12 INST ALLA TION POWER WAVE 455/STT A-12 I / O RECEPT ACLE SPECIFICA TIONS TABLE 3 WIRE FEEDER RECEPTACLE S1 PIN LEAD# FUNCTION A 53 Communication Bus L B 54 Communication Bus H C 67A Electrode Vol.
B-1 OPERA TION B-1 POWER WAVE 455/STT SAFETY PRECAUTIONS Read this entire section of operating instructions before operating the machine. ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrodes with your skin or wet clothing. • Insulate yourself from the work and ground.
B-2 OPERA TION B-2 POWER WAVE 455/STT INPUT POWER ON OFF HIGH TEMPERA TURE MACHINE ST A TUS CIRCUIT BREAKER WIRE FEEDER POSITIVE OUTPUT NEGA TIVE OUTPUT 3 PHASE INVERTER INPUT POWER THREE PHASE DIRECT.
RECOMMENDED EQUIPMENT Power Wave 455/STT – Semi-Automatic Operation Semi Automatic Power Waves can only be used with Linc-Net compatible Power Feed semi-automatic wire feeders. In addition, the Power Feed semi-automatic wire feeders may require optional equipment to access certain weld modes in the Power Wave.
B-4 OPERA TION POWER WAVE 455/STT B-4 CASE FRONT CONTROLS All operator controls and adjustments are located on the case front of the Power Wave. (See Figure A.4) 1 . POWER SWITCH: Controls input power to the Power Wave. 2. STATUS LIGHT: A two color light that indicates system errors.
B-5 OPERA TION B-5 NOMINAL PROCEDURES The Power Wave is designed to operate with 3/4" electrode stick-out for CV and Pulse processes and a 1/2" stick-out for STT processes. FRINGE PROCEDURES Excessively short or long electrode stick-outs may function only on a limited basis, if at all.
B-6 OPERA TION B-6 • VOLTS / TRIM: In constant voltage modes (synergic CV, standard CV) the control adjusts the welding voltage. In pulse synergic welding modes (pulse GMAW only) the user can change the Trim setting to adjust the arc length. It is adjustable from 0.
B-7 OPERA TION B-7 CONST ANT VOL T AGE WELDING Synergic CV : For each wire feed speed, a corresponding voltage is preprogrammed into the machine through special soft- ware at the factory. The nominal preprogrammed volt- age is the best average voltage for a given wire feed speed, but may be adjusted to preference.
B-8 OPERA TION B-8 PULSE WELDING Pulse welding procedures are set by controlling an overall "arc length" variable. When pulse welding, the arc voltage is highly dependent upon the waveform. The peak current, back ground current, rise time, fall time and pulse frequency all affect the voltage.
B-9 OPERA TION B-9 STT WELDING The pictures illustrate the waveshape of current for the process. They are not drawn to scale, and are intended only for the purpose of showing how the vari- ables effect the waveform. Trim in the STT mode adjusts the tailout and back- ground portion of the waveform.
C-1 ACCESSORIES C-1 OPTIONAL EQUIPMENT F ACTOR Y INST ALLED None Available. FIELD INST ALLED Work Voltage Sense Lead Kit, K940 Dual Cylinder Undercarriage, K1570-1.
D-1 MAINTENANCE D-1 POWER WAVE 455/STT SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only Qualified personnel should perform this maintenance. • Turn the input power OFF at the disconnect switch or fuse box before working on this equipment. • Do not touch electrically hot parts.
E-1 TROUBLESHOOTING E-1 POWER WAVE 455/STT If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 POWER WAVE 455/STT USING THE ST A TUS LED TO TROUBLESHOOT SYSTEM PROBLEMS The Power Wave / Power Feed are best diagnosed as a system. Each component (power source, user inter- face, and feedhead) has a status light, and when a problem occurs it is important to note the condition of each.
E-3 TROUBLESHOOTING E-3 POWER WAVE 455/STT Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TROUBLESHOOTING E-4 POWER WAVE 455/STT Observe all Safety Guidelines detailed throughout this manual TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
E-5 TROUBLESHOOTING E-5 POWER WAVE 455/STT Observe all Safety Guidelines detailed throughout this manual TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
E-6 TROUBLESHOOTING E-6 POWER WAVE 455/STT Observe all Safety Guidelines detailed throughout this manual TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
E-7 TROUBLESHOOTING E-7 POWER WAVE 455/STT Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIAGRAMS F-1 POWER WAVE 455/STT NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-2 CONNECTION DIAGRAM F-2 POWER WAVE 455/STT Connection Diagram Semi-automatic "Simple System" (Electrode Positive,CV/Pulse Configuration shown) POWER WAVE / STT CV/PULSE STUD WIRE FEEDER C.
F-3 DIAGRAMS F-3 POWER WAVE 455 Connection Diagram Semi-automatic "Simple System" (Electrode Positive, STT Configuration shown) POWER WAVE / STT STT STUD WIRE FEEDER CONTROL CABLE K1543 TO W.
F-4 DIAGRAMS F-4 POWER WAVE 455/STT 32.88 26.10 22.63 12.35 19.00 19.90 19.16 9.48 14.62 23.12 23.51 11-14-97 M18241 DIMENSION PRINT - PO WER W A VE 455.
NOTES POWER WAVE 455/STT.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P AR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lincoln Electric POWER WAVE IM716 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lincoln Electric POWER WAVE IM716 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lincoln Electric POWER WAVE IM716, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lincoln Electric POWER WAVE IM716 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lincoln Electric POWER WAVE IM716, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lincoln Electric POWER WAVE IM716.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lincoln Electric POWER WAVE IM716. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lincoln Electric POWER WAVE IM716 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.